Summary

Details

Page properties
Content
... ... @@ -60,8 +60,6 @@
60 60  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
61 61  
62 62  
63 -
64 -
65 65  == **1.3 Example3: Use RS485-LN with energy meters** ==
66 66  
67 67  
... ... @@ -113,12 +113,12 @@
113 113  Connection2
114 114  
115 115  
116 -
117 117  [[image:image-20220527092555-7.png]]
118 118  
119 119  Connection3
120 120  
121 121  
119 +
122 122  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
123 123  
124 124  
... ... @@ -165,6 +165,7 @@
165 165  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
166 166  
167 167  
166 +
168 168  ==== **1.3.3.1 via AT COMMAND** ====
169 169  
170 170  
... ... @@ -220,7 +220,7 @@
220 220  (((
221 221  (% style="color:blue" %)**Example**:
222 222  
223 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
222 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
224 224  )))
225 225  
226 226  (((
... ... @@ -234,7 +234,7 @@
234 234  )))
235 235  
236 236  (((
237 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
236 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
238 238  )))
239 239  
240 240  (((
... ... @@ -248,7 +248,7 @@
248 248  )))
249 249  
250 250  (((
251 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
250 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
252 252  )))
253 253  
254 254  (((
... ... @@ -276,6 +276,7 @@
276 276  AT COMMAND
277 277  
278 278  
278 +
279 279  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
280 280  
281 281  
... ... @@ -375,6 +375,7 @@
375 375  DOWNLINK
376 376  
377 377  
378 +
378 378  === **1.3.4 How to configure and output commands for RS485 to USB** ===
379 379  
380 380  (((
... ... @@ -432,6 +432,7 @@
432 432  USB
433 433  
434 434  
436 +
435 435  === **1.3.5 How to configure multiple devices and modify device addresses** ===
436 436  
437 437  
... ... @@ -506,7 +506,7 @@
506 506  [[image:image-20220601142607-4.png]]
507 507  
508 508  
509 -**PAYLOAD:01 08 DF 43 62**
511 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
510 510  
511 511  * 08 DF is the valid value of the meter with device address 02.
512 512  * 43 62 is the valid value of the meter with device address 01.
... ... @@ -513,6 +513,7 @@
513 513  
514 514  
515 515  
518 +
516 516  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
517 517  
518 518  
... ... @@ -529,6 +529,7 @@
529 529  
530 530  
531 531  
535 +
532 532  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
533 533  
534 534  
... ... @@ -539,6 +539,7 @@
539 539  
540 540  
541 541  
546 +
542 542  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
543 543  
544 544  
... ... @@ -546,8 +546,6 @@
546 546  
547 547  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
548 548  
549 -
550 -
551 551  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
552 552  
553 553  