... ... @@ -35,8 +35,6 @@
35 35  * Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
36 36  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
37 37  
38 -
39 -
40 40  == **1.2 Example 2: Connect to Pulse Counter** ==
41 41  
42 42  
... ... @@ -61,7 +61,6 @@
61 61  
62 62  
63 63  
64 -
65 65  == **1.3 Example3: Use RS485-LN with energy meters** ==
66 66  
67 67  
... ... @@ -113,7 +113,6 @@
113 113  Connection2
114 114  
115 115  
116 -
117 117  [[image:image-20220527092555-7.png]]
118 118  
119 119  Connection3
... ... @@ -220,7 +220,7 @@
220 220  (((
221 221  (% style="color:blue" %)**Example**:
222 222  
223 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
219 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
224 224  )))
225 225  
226 226  (((
... ... @@ -234,7 +234,7 @@
234 234  )))
235 235  
236 236  (((
237 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
233 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
238 238  )))
239 239  
240 240  (((
... ... @@ -248,7 +248,7 @@
248 248  )))
249 249  
250 250  (((
251 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
247 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
252 252  )))
253 253  
254 254  (((
... ... @@ -511,8 +511,6 @@
511 511  * 08 DF is the valid value of the meter with device address 02.
512 512  * 43 62 is the valid value of the meter with device address 01.
513 513  
514 -
515 -
516 516  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
517 517  
518 518  
... ... @@ -527,8 +527,6 @@
527 527  
528 528  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
529 529  
530 -
531 -
532 532  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
533 533  
534 534  
... ... @@ -537,8 +537,6 @@
537 537  * Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
538 538  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
539 539  
540 -
541 -
542 542  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
543 543  
544 544  
... ... @@ -546,8 +546,6 @@
546 546  
547 547  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
548 548  
549 -
550 -
551 551  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
552 552  
553 553  