Last modified by Karry Zhuang on 2024/07/11 11:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -31,12 +31,11 @@ 31 31 32 32 (% style="color:blue" %)**Related documents:** 33 33 34 -* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]] 35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]] 34 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 35 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 38 38 39 - 40 40 == **1.2 Example 2: Connect to Pulse Counter** == 41 41 42 42 ... ... @@ -56,14 +56,13 @@ 56 56 57 57 (% style="color:blue" %)**Related documents:** 58 58 59 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 58 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 60 60 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 61 61 62 62 63 - 64 - 65 65 == **1.3 Example3: Use RS485-LN with energy meters** == 66 66 64 + 67 67 === **1.3.1 OverView** === 68 68 69 69 ... ... @@ -82,7 +82,7 @@ 82 82 83 83 84 84 ((( 85 -**How to connect with Energy Meter:** 83 +(% style="color:blue" %)**How to connect with Energy Meter:** 86 86 87 87 88 88 ))) ... ... @@ -112,12 +112,12 @@ 112 112 Connection2 113 113 114 114 115 - 116 116 [[image:image-20220527092555-7.png]] 117 117 118 118 Connection3 119 119 120 120 118 + 121 121 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 122 122 123 123 ... ... @@ -164,6 +164,7 @@ 164 164 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 165 165 166 166 165 + 167 167 ==== **1.3.3.1 via AT COMMAND** ==== 168 168 169 169 ... ... @@ -180,7 +180,7 @@ 180 180 181 181 (% class="box infomessage" %) 182 182 ((( 183 - **AT+DATACUTx **: This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 182 + (% _mstmutation="1" %)**AT+DATACUTx **(%%): This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 184 184 ))) 185 185 186 186 a: length for the return of AT+COMMAND ... ... @@ -219,7 +219,7 @@ 219 219 ((( 220 220 (% style="color:blue" %)**Example**: 221 221 222 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 221 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 223 223 ))) 224 224 225 225 ((( ... ... @@ -233,7 +233,7 @@ 233 233 ))) 234 234 235 235 ((( 236 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 235 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 237 237 ))) 238 238 239 239 ((( ... ... @@ -247,7 +247,7 @@ 247 247 ))) 248 248 249 249 ((( 250 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 249 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 251 251 ))) 252 252 253 253 ((( ... ... @@ -275,6 +275,7 @@ 275 275 AT COMMAND 276 276 277 277 277 + 278 278 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 279 279 280 280 ... ... @@ -300,7 +300,7 @@ 300 300 ))) 301 301 302 302 ((( 303 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 303 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 304 304 ))) 305 305 306 306 ((( ... ... @@ -374,6 +374,7 @@ 374 374 DOWNLINK 375 375 376 376 377 + 377 377 === **1.3.4 How to configure and output commands for RS485 to USB** === 378 378 379 379 ((( ... ... @@ -431,6 +431,7 @@ 431 431 USB 432 432 433 433 435 + 434 434 === **1.3.5 How to configure multiple devices and modify device addresses** === 435 435 436 436 ... ... @@ -461,7 +461,7 @@ 461 461 462 462 ((( 463 463 ((( 464 -We can use **AT+CFGDEV** to set the device address. 466 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address. 465 465 ))) 466 466 ))) 467 467 ... ... @@ -505,13 +505,12 @@ 505 505 [[image:image-20220601142607-4.png]] 506 506 507 507 508 -**PAYLOAD:01 08 DF 43 62** 510 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62** 509 509 510 510 * 08 DF is the valid value of the meter with device address 02. 511 511 * 43 62 is the valid value of the meter with device address 01. 512 512 513 513 514 - 515 515 == 1.4 Example 4: Circuit Breaker Remote Open Close == 516 516 517 517 ... ... @@ -524,29 +524,26 @@ 524 524 Connection 525 525 526 526 527 -* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 528 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 528 528 529 529 530 - 531 531 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 532 532 533 533 534 534 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 535 535 536 -* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 537 -* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 536 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 537 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 538 538 539 539 540 - 541 541 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 542 542 543 543 544 544 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 545 545 546 -* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]] 545 +* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 547 547 548 548 549 - 550 550 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 551 551 552 552