... ... @@ -35,8 +35,6 @@
35 35  * Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
36 36  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
37 37  
38 -
39 -
40 40  == **1.2 Example 2: Connect to Pulse Counter** ==
41 41  
42 42  
... ... @@ -61,9 +61,9 @@
61 61  
62 62  
63 63  
64 -
65 65  == **1.3 Example3: Use RS485-LN with energy meters** ==
66 66  
64 +
67 67  === **1.3.1 OverView** ===
68 68  
69 69  
... ... @@ -82,7 +82,7 @@
82 82  
83 83  
84 84  (((
85 -**How to connect with Energy Meter:**
83 +(% style="color:blue" %)**How to connect with Energy Meter:**
86 86  
87 87  
88 88  )))
... ... @@ -112,7 +112,6 @@
112 112  Connection2
113 113  
114 114  
115 -
116 116  [[image:image-20220527092555-7.png]]
117 117  
118 118  Connection3
... ... @@ -219,7 +219,7 @@
219 219  (((
220 220  (% style="color:blue" %)**Example**:
221 221  
222 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
219 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
223 223  )))
224 224  
225 225  (((
... ... @@ -233,7 +233,7 @@
233 233  )))
234 234  
235 235  (((
236 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
233 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
237 237  )))
238 238  
239 239  (((
... ... @@ -247,7 +247,7 @@
247 247  )))
248 248  
249 249  (((
250 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
247 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
251 251  )))
252 252  
253 253  (((
... ... @@ -510,8 +510,6 @@
510 510  * 08 DF is the valid value of the meter with device address 02.
511 511  * 43 62 is the valid value of the meter with device address 01.
512 512  
513 -
514 -
515 515  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
516 516  
517 517  
... ... @@ -526,8 +526,6 @@
526 526  
527 527  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
528 528  
529 -
530 -
531 531  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
532 532  
533 533  
... ... @@ -536,8 +536,6 @@
536 536  * Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
537 537  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
538 538  
539 -
540 -
541 541  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
542 542  
543 543  
... ... @@ -545,8 +545,6 @@
545 545  
546 546  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
547 547  
548 -
549 -
550 550  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
551 551  
552 552  