Last modified by Karry Zhuang on 2024/07/11 11:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -29,12 +29,13 @@ 29 29 Connection 30 30 31 31 32 -Related documents: 32 +(% style="color:blue" %)**Related documents:** 33 33 34 -* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/ ]] : SystemStructure35 -* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/ ]] : Explanationon howto integrate toNode-red andtothe MobilePhone,andwith link to the Github code.34 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 35 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 38 + 38 38 == **1.2 Example 2: Connect to Pulse Counter** == 39 39 40 40 ... ... @@ -52,11 +52,15 @@ 52 52 Connection 53 53 54 54 55 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 56 +(% style="color:blue" %)**Related documents:** 57 + 58 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 56 56 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 57 57 61 + 58 58 == **1.3 Example3: Use RS485-LN with energy meters** == 59 59 64 + 60 60 === **1.3.1 OverView** === 61 61 62 62 ... ... @@ -75,7 +75,7 @@ 75 75 76 76 77 77 ((( 78 -**How to connect with Energy Meter:** 83 +(% style="color:blue" %)**How to connect with Energy Meter:** 79 79 80 80 81 81 ))) ... ... @@ -105,12 +105,12 @@ 105 105 Connection2 106 106 107 107 108 - 109 109 [[image:image-20220527092555-7.png]] 110 110 111 111 Connection3 112 112 113 113 118 + 114 114 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 115 115 116 116 ... ... @@ -157,6 +157,7 @@ 157 157 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 158 158 159 159 165 + 160 160 ==== **1.3.3.1 via AT COMMAND** ==== 161 161 162 162 ... ... @@ -173,7 +173,7 @@ 173 173 174 174 (% class="box infomessage" %) 175 175 ((( 176 - **AT+DATACUTx **: This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 182 + (% _mstmutation="1" %)**AT+DATACUTx **(%%): This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 177 177 ))) 178 178 179 179 a: length for the return of AT+COMMAND ... ... @@ -212,7 +212,7 @@ 212 212 ((( 213 213 (% style="color:blue" %)**Example**: 214 214 215 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 221 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 216 216 ))) 217 217 218 218 ((( ... ... @@ -226,7 +226,7 @@ 226 226 ))) 227 227 228 228 ((( 229 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 235 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 230 230 ))) 231 231 232 232 ((( ... ... @@ -240,7 +240,7 @@ 240 240 ))) 241 241 242 242 ((( 243 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 249 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 244 244 ))) 245 245 246 246 ((( ... ... @@ -268,6 +268,7 @@ 268 268 AT COMMAND 269 269 270 270 277 + 271 271 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 272 272 273 273 ... ... @@ -293,7 +293,7 @@ 293 293 ))) 294 294 295 295 ((( 296 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 303 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 297 297 ))) 298 298 299 299 ((( ... ... @@ -367,6 +367,7 @@ 367 367 DOWNLINK 368 368 369 369 377 + 370 370 === **1.3.4 How to configure and output commands for RS485 to USB** === 371 371 372 372 ((( ... ... @@ -424,6 +424,7 @@ 424 424 USB 425 425 426 426 435 + 427 427 === **1.3.5 How to configure multiple devices and modify device addresses** === 428 428 429 429 ... ... @@ -454,7 +454,7 @@ 454 454 455 455 ((( 456 456 ((( 457 -We can use **AT+CFGDEV** to set the device address. 466 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address. 458 458 ))) 459 459 ))) 460 460 ... ... @@ -498,14 +498,12 @@ 498 498 [[image:image-20220601142607-4.png]] 499 499 500 500 501 -**PAYLOAD:01 08 DF 43 62** 510 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62** 502 502 503 503 * 08 DF is the valid value of the meter with device address 02. 504 504 * 43 62 is the valid value of the meter with device address 01. 505 505 506 506 507 - 508 - 509 509 == 1.4 Example 4: Circuit Breaker Remote Open Close == 510 510 511 511 ... ... @@ -518,32 +518,26 @@ 518 518 Connection 519 519 520 520 521 -* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 528 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 522 522 523 523 524 - 525 - 526 526 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 527 527 528 528 529 529 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 530 530 531 -* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 532 -* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 536 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 537 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 533 533 534 534 535 - 536 - 537 537 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 538 538 539 539 540 540 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 541 541 542 -* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]] 545 +* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 543 543 544 544 545 - 546 - 547 547 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 548 548 549 549