Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -29,12 +29,15 @@ 29 29 Connection 30 30 31 31 32 -Related documents: 32 +(% style="color:blue" %)**Related documents:** 33 33 34 -* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/ ]] : System Structure35 -* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/ ]] : Explanation on how to integrate toNode-red andtothe MobilePhone,andwith link to the Github code.34 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]] 35 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]] 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 38 + 39 + 40 + 38 38 == **1.2 Example 2: Connect to Pulse Counter** == 39 39 40 40 ... ... @@ -52,11 +52,16 @@ 52 52 Connection 53 53 54 54 55 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 58 +(% style="color:blue" %)**Related documents:** 59 + 60 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 56 56 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 57 57 63 + 64 + 58 58 == **1.3 Example3: Use RS485-LN with energy meters** == 59 59 67 + 60 60 === **1.3.1 OverView** === 61 61 62 62 ... ... @@ -75,7 +75,7 @@ 75 75 76 76 77 77 ((( 78 -**How to connect with Energy Meter:** 86 +(% style="color:blue" %)**How to connect with Energy Meter:** 79 79 80 80 81 81 ))) ... ... @@ -105,7 +105,6 @@ 105 105 Connection2 106 106 107 107 108 - 109 109 [[image:image-20220527092555-7.png]] 110 110 111 111 Connection3 ... ... @@ -212,7 +212,7 @@ 212 212 ((( 213 213 (% style="color:blue" %)**Example**: 214 214 215 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 222 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 216 216 ))) 217 217 218 218 ((( ... ... @@ -226,7 +226,7 @@ 226 226 ))) 227 227 228 228 ((( 229 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 236 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 230 230 ))) 231 231 232 232 ((( ... ... @@ -240,7 +240,7 @@ 240 240 ))) 241 241 242 242 ((( 243 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 250 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 244 244 ))) 245 245 246 246 ((( ... ... @@ -503,9 +503,6 @@ 503 503 * 08 DF is the valid value of the meter with device address 02. 504 504 * 43 62 is the valid value of the meter with device address 01. 505 505 506 - 507 - 508 - 509 509 == 1.4 Example 4: Circuit Breaker Remote Open Close == 510 510 511 511 ... ... @@ -520,9 +520,6 @@ 520 520 521 521 * Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 522 522 523 - 524 - 525 - 526 526 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 527 527 528 528 ... ... @@ -531,9 +531,6 @@ 531 531 * Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 532 532 * Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 533 533 534 - 535 - 536 - 537 537 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 538 538 539 539 ... ... @@ -541,9 +541,6 @@ 541 541 542 542 * Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]] 543 543 544 - 545 - 546 - 547 547 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 548 548 549 549