... ... @@ -29,12 +29,13 @@
29 29  Connection
30 30  
31 31  
32 -Related documents:
32 +(% style="color:blue" %)**Related documents:**
33 33  
34 -* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure
35 -* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
34 +* System Structure:  [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
35 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
36 36  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
37 37  
38 +
38 38  == **1.2 Example 2: Connect to Pulse Counter** ==
39 39  
40 40  
... ... @@ -52,11 +52,16 @@
52 52  Connection
53 53  
54 54  
55 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
56 +(% style="color:blue" %)**Related documents:**
57 +
58 +* Configure Document:  [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
56 56  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
57 57  
61 +
62 +
58 58  == **1.3 Example3: Use RS485-LN with energy meters** ==
59 59  
65 +
60 60  === **1.3.1 OverView** ===
61 61  
62 62  
... ... @@ -75,7 +75,7 @@
75 75  
76 76  
77 77  (((
78 -**How to connect with Energy Meter:**
84 +(% style="color:blue" %)**How to connect with Energy Meter:**
79 79  
80 80  
81 81  )))
... ... @@ -105,7 +105,6 @@
105 105  Connection2
106 106  
107 107  
108 -
109 109  [[image:image-20220527092555-7.png]]
110 110  
111 111  Connection3
... ... @@ -212,7 +212,7 @@
212 212  (((
213 213  (% style="color:blue" %)**Example**:
214 214  
215 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
220 +**CMD1:** Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
216 216  )))
217 217  
218 218  (((
... ... @@ -226,7 +226,7 @@
226 226  )))
227 227  
228 228  (((
229 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
234 +**CMD2: **Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
230 230  )))
231 231  
232 232  (((
... ... @@ -240,7 +240,7 @@
240 240  )))
241 241  
242 242  (((
243 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
248 +**CMD3:** Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
244 244  )))
245 245  
246 246  (((
... ... @@ -504,8 +504,6 @@
504 504  * 43 62 is the valid value of the meter with device address 01.
505 505  
506 506  
507 -
508 -
509 509  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
510 510  
511 511  
... ... @@ -521,8 +521,6 @@
521 521  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
522 522  
523 523  
524 -
525 -
526 526  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
527 527  
528 528  
... ... @@ -532,8 +532,6 @@
532 532  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
533 533  
534 534  
535 -
536 -
537 537  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
538 538  
539 539  
... ... @@ -542,8 +542,6 @@
542 542  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
543 543  
544 544  
545 -
546 -
547 547  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
548 548  
549 549  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved