Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,4 @@ 1 -(% class="wikigeneratedid" %) 2 -* 3 -** Table of** **Contents: 1 +**Table of Contents:** 4 4 5 5 {{toc/}} 6 6 ... ... @@ -9,75 +9,87 @@ 9 9 10 10 11 11 12 -= **1. Introduction**=10 += 1. Introduction = 13 13 14 14 15 15 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 16 16 17 17 18 -== **1.1 Example 1: Connect to Leak relay and VFD**==16 +== 1.1 Example 1: Connect to Leak relay and VFD == 19 19 20 20 21 21 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 22 22 23 -[[image:image-20220527091852-1.png]] 24 24 25 - Connection22 +[[image:image-20220527091852-1.png||height="547" width="994"]] 26 26 24 +**Connection** 27 27 28 28 27 + 29 29 [[image:image-20220527091942-2.png]](% style="display:none" %) 30 30 31 -Connection 30 +**Connection** 32 32 33 33 34 -Related documents: 33 +(% style="color:blue" %)**Related documents:** 35 35 36 -* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure 37 -* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 35 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 36 + 37 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 38 + 38 38 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 39 39 40 -== **1.2 Example 2: Connect to Pulse Counter** == 41 41 42 42 43 +== 1.2 Example 2: Connect to Pulse Counter == 44 + 45 + 43 43 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 44 44 45 45 46 -[[image:image-20220527092058-3.png]] 49 +[[image:image-20220527092058-3.png||height="552" width="905"]] 47 47 48 -Connection 51 +**Connection** 49 49 50 50 51 51 52 -[[image:image-20220527092146-4.png]] 55 +[[image:image-20220527092146-4.png||height="507" width="906"]] 53 53 54 -Connection 57 +**Connection** 55 55 56 56 57 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 60 +(% style="color:blue" %)**Related documents:** 61 + 62 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 63 + 58 58 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 59 59 60 -== **1.3 Example3: Use RS485-LN with energy meters** == 61 61 62 -=== **1.3.1 OverView** === 63 63 68 +== 1.3 Example 3: Use RS485-LN with energy meters == 64 64 70 +=== 1.3.1 OverView === 71 + 72 + 65 65 ((( 66 -(% style="color:red" %)**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 74 +(% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.** 67 67 ))) 68 68 69 69 ((( 70 70 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 79 + 80 + 71 71 ))) 72 72 73 73 [[image:image-20220527092419-5.png]] 74 74 75 -Connection1 85 +**Connection1** 76 76 77 77 78 78 79 79 ((( 80 -**How to connect with Energy Meter:** 90 +(% style="color:blue" %)**How to connect with Energy Meter:** 81 81 82 82 83 83 ))) ... ... @@ -91,29 +91,31 @@ 91 91 ))) 92 92 93 93 ((( 94 -Power Source VIN to RS485-LN VIN+ 104 +Power Source **VIN** to RS485-LN **VIN+** 95 95 ))) 96 96 97 97 ((( 98 -Power Source GND to RS485-LN VIN- 108 +Power Source **GND** to RS485-LN **VIN-** 99 99 ))) 100 100 101 101 ((( 102 102 Once there is power, the RS485-LN will be on. 113 + 114 + 103 103 ))) 104 104 105 105 [[image:image-20220527092514-6.png]] 106 106 107 -Connection2 119 +**Connection2** 108 108 109 109 110 110 111 111 [[image:image-20220527092555-7.png]] 112 112 113 -Connection3 125 +**Connection3** 114 114 115 115 116 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands**===128 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 117 117 118 118 119 119 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. ... ... @@ -124,9 +124,13 @@ 124 124 (% style="color:blue" %)**Example:**(%%) AT+COMMAND1=01 03 00 00 00 01 84 0A 125 125 126 126 * The first byte : slave address code (=001~247) 139 + 127 127 * The second byte : read register value function code 141 + 128 128 * 3rd and 4th bytes: start address of register to be read 143 + 129 129 * 5th and 6th bytes: Number of registers to read 145 + 130 130 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6. 131 131 132 132 ((( ... ... @@ -139,23 +139,22 @@ 139 139 ))) 140 140 141 141 * The first byte ARD: slave address code (=001~254) 158 + 142 142 * The second byte: Return to read function code 160 + 143 143 * 3rd byte: total number of bytes 162 + 144 144 * 4th~5th bytes: register data 164 + 145 145 * The 6th and 7th bytes: CRC16 checksum 166 + 146 146 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 147 147 148 -(% class="wikigeneratedid" %) 149 -((( 150 - 151 151 152 152 153 - 154 -))) 171 +=== 1.3.3 How to configure RS485-LN and parse output commands === 155 155 156 -=== **1.3.3 How to configure RS485-LN and parse output commands** === 157 157 158 - 159 159 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 160 160 161 161 ... ... @@ -166,16 +166,18 @@ 166 166 167 167 ((( 168 168 If the configured parameters and commands are incorrect, the return value is not obtained. 184 + 185 + 169 169 ))) 170 170 171 171 [[image:image-20220601143201-9.png]] 172 172 173 -AT COMMAND 190 +**AT COMMAND** 174 174 175 175 176 176 (% class="box infomessage" %) 177 177 ((( 178 - **AT+DATACUTx **: This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 195 + (% _mstmutation="1" %)**AT+DATACUTx **(%%): This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 179 179 ))) 180 180 181 181 a: length for the return of AT+COMMAND ... ... @@ -186,16 +186,15 @@ 186 186 187 187 [[image:image-20220601143115-8.png]] 188 188 189 -AT COMMAND 206 +**AT COMMAND** 190 190 191 191 192 192 193 193 PAYLOAD is available after the valid value is intercepted. 194 194 195 - 196 196 [[image:image-20220601143046-7.png]] 197 197 198 -AT COMMAND 214 +**AT COMMAND** 199 199 200 200 201 201 ... ... @@ -204,7 +204,7 @@ 204 204 [[image:image-20220601143519-1.png]] 205 205 206 206 ((( 207 -AT COMMAND 223 +**AT COMMAND** 208 208 ))) 209 209 210 210 ((( ... ... @@ -214,7 +214,7 @@ 214 214 ((( 215 215 (% style="color:blue" %)**Example**: 216 216 217 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 233 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 218 218 ))) 219 219 220 220 ((( ... ... @@ -228,7 +228,7 @@ 228 228 ))) 229 229 230 230 ((( 231 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 247 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 232 232 ))) 233 233 234 234 ((( ... ... @@ -242,7 +242,7 @@ 242 242 ))) 243 243 244 244 ((( 245 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 261 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 246 246 ))) 247 247 248 248 ((( ... ... @@ -262,14 +262,16 @@ 262 262 AT COMMAND 263 263 264 264 265 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 266 266 282 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 267 267 284 + 268 268 [[image:image-20220601143642-2.png]] 269 269 270 270 AT COMMAND 271 271 272 272 290 + 273 273 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 274 274 275 275 ... ... @@ -276,15 +276,13 @@ 276 276 [[image:image-20220527093358-15.png]] 277 277 278 278 ((( 279 -DOWNLINK 297 +**DOWNLINK** 280 280 ))) 281 281 282 -((( 283 - 284 -))) 285 285 301 + 286 286 ((( 287 -(% style="color: #4f81bd" %)**Type Code 0xAF**303 +(% style="color:blue" %)**Type Code 0xAF** 288 288 ))) 289 289 290 290 ((( ... ... @@ -295,7 +295,7 @@ 295 295 ))) 296 296 297 297 ((( 298 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 314 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 299 299 ))) 300 300 301 301 ((( ... ... @@ -330,9 +330,8 @@ 330 330 will execute an uplink after got this command. 331 331 ))) 332 332 333 -((( 334 - 335 335 350 +((( 336 336 (% style="color:blue" %)**Example:** 337 337 ))) 338 338 ... ... @@ -342,35 +342,36 @@ 342 342 343 343 [[image:image-20220601144149-6.png]] 344 344 345 -DOWNLINK 360 +**DOWNLINK** 346 346 347 347 348 348 349 349 [[image:image-20220601143803-3.png]] 350 350 351 -DOWNLINK 366 +**DOWNLINK** 352 352 353 353 354 354 355 355 [[image:image-20220601144053-5.png]] 356 356 357 -DOWNLINK 372 +**DOWNLINK** 358 358 359 359 360 360 361 361 [[image:image-20220601143921-4.png]] 362 362 363 -DOWNLINK 378 +**DOWNLINK** 364 364 365 365 366 366 367 367 [[image:image-20220601142805-5.png]] 368 368 369 -DOWNLINK 370 - 384 +**DOWNLINK** 371 371 372 -=== **1.3.4 How to configure and output commands for RS485 to USB** === 373 373 387 +=== 1.3.4 How to configure and output commands for RS485 to USB === 388 + 389 + 374 374 ((( 375 375 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN. 376 376 ))) ... ... @@ -395,20 +395,18 @@ 395 395 396 396 [[image:image-20220527093708-21.png]] 397 397 398 -USB 414 +**USB** 399 399 400 400 401 401 402 402 [[image:image-20220527093747-22.png]] 403 403 404 -USB 420 +**USB** 405 405 406 406 407 407 408 408 ((( 409 409 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 410 - 411 - 412 412 ))) 413 413 414 414 ((( ... ... @@ -423,12 +423,13 @@ 423 423 424 424 [[image:image-20220527093821-23.png]] 425 425 426 -USB 440 +**USB** 427 427 428 428 429 -=== **1.3.5 How to configure multiple devices and modify device addresses** === 430 430 444 +=== 1.3.5 How to configure multiple devices and modify device addresses === 431 431 446 + 432 432 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 433 433 434 434 ((( ... ... @@ -442,6 +442,7 @@ 442 442 443 443 (% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 444 444 460 + 445 445 [[image:image-20220527093950-25.png]] 446 446 447 447 ... ... @@ -456,7 +456,7 @@ 456 456 457 457 ((( 458 458 ((( 459 -We can use **AT+CFGDEV** to set the device address. 475 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address. 460 460 ))) 461 461 ))) 462 462 ... ... @@ -474,9 +474,9 @@ 474 474 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** 475 475 ))) 476 476 477 -* 01:device adaress 493 +* 01: device adaress 478 478 479 -* 10:function code 495 +* 10: function code 480 480 481 481 * 00 61:Register address 482 482 ... ... @@ -500,14 +500,14 @@ 500 500 [[image:image-20220601142607-4.png]] 501 501 502 502 503 -**PAYLOAD:01 08 DF 43 62** 519 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62** 504 504 505 505 * 08 DF is the valid value of the meter with device address 02. 506 506 * 43 62 is the valid value of the meter with device address 01. 507 507 524 +(% style="display:none" %) (%%) 508 508 509 509 510 - 511 511 == 1.4 Example 4: Circuit Breaker Remote Open Close == 512 512 513 513 ... ... @@ -517,38 +517,36 @@ 517 517 518 518 [[image:image-20220527094330-30.png]] 519 519 520 -Connection 536 +**Connection** 521 521 522 522 523 -* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 539 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 524 524 525 525 526 526 527 - 528 528 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 529 529 530 530 531 531 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 532 532 533 -* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 534 -* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 548 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 535 535 550 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 536 536 537 537 538 538 539 -== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 554 +== 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 540 540 541 541 542 542 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 543 543 544 -* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]] 559 +* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 545 545 546 546 547 547 563 +== 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 548 548 549 -== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 550 550 551 - 552 552 [[image:image-20220527094556-31.png]] 553 553 554 554 Network Structure