Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% class="wikigeneratedid" %) 2 -* 2 +* 3 3 ** Table of** **Contents: 4 4 5 5 {{toc/}} ... ... @@ -295,7 +295,7 @@ 295 295 ))) 296 296 297 297 ((( 298 - (% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.298 +Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 299 299 ))) 300 300 301 301 ((( ... ... @@ -333,7 +333,7 @@ 333 333 ((( 334 334 335 335 336 -(% style="color:b lue" %)**Example:**336 +(% style="color:#4f81bd" %)**Example:** 337 337 ))) 338 338 339 339 ((( ... ... @@ -389,8 +389,6 @@ 389 389 390 390 ((( 391 391 check digit: Even 392 - 393 - 394 394 ))) 395 395 396 396 [[image:image-20220527093708-21.png]] ... ... @@ -407,18 +407,14 @@ 407 407 408 408 ((( 409 409 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 410 - 411 - 412 412 ))) 413 413 414 414 ((( 415 -(% style="color:b lue" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4411 +(% style="color:#4f81bd" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4 416 416 ))) 417 417 418 418 ((( 419 419 output:01 03 04 00 00 00 42 7A 02 420 - 421 - 422 422 ))) 423 423 424 424 [[image:image-20220527093821-23.png]] ... ... @@ -428,7 +428,6 @@ 428 428 429 429 === **1.3.5 How to configure multiple devices and modify device addresses** === 430 430 431 - 432 432 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 433 433 434 434 ((( ... ... @@ -440,7 +440,7 @@ 440 440 [[image:image-20220601142044-1.png]] 441 441 442 442 443 - (% style="color:blue" %)**Example**(%%):436 +**Example**:These two meters are examples of setting parameters and device addresses. 444 444 445 445 [[image:image-20220527093950-25.png]] 446 446 ... ... @@ -447,7 +447,6 @@ 447 447 448 448 [[image:image-20220527094028-26.png]] 449 449 450 - 451 451 ((( 452 452 ((( 453 453 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. ... ... @@ -456,7 +456,7 @@ 456 456 457 457 ((( 458 458 ((( 459 -We can use **AT+CFGDEV**to set the device address.451 +We can use AT+CFGDEV to set the device address. 460 460 ))) 461 461 ))) 462 462 ... ... @@ -468,7 +468,6 @@ 468 468 469 469 [[image:image-20220601142354-2.png]] 470 470 471 - 472 472 (% class="box infomessage" %) 473 473 ((( 474 474 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** ... ... @@ -499,59 +499,39 @@ 499 499 500 500 [[image:image-20220601142607-4.png]] 501 501 502 - 503 503 **PAYLOAD:01 08 DF 43 62** 504 504 505 505 * 08 DF is the valid value of the meter with device address 02. 506 506 * 43 62 is the valid value of the meter with device address 01. 507 507 508 - 509 - 510 - 511 511 == 1.4 Example 4: Circuit Breaker Remote Open Close == 512 512 500 +This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: 513 513 514 -This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. 515 - 516 -The structure is like below: 517 - 518 518 [[image:image-20220527094330-30.png]] 519 519 520 520 Connection 521 521 506 +* [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 522 522 523 -* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 524 - 525 - 526 - 527 - 528 528 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 529 529 530 - 531 531 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 532 532 533 -* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 534 -* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 512 +* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf]] : Configure Document For RS485-BL 535 535 514 +* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 536 536 537 - 538 - 539 539 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 540 540 541 - 542 542 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 543 543 544 -* Configure Document For RS485-LN:[[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color:rgb(255, 255, 255);"]]520 +* [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 545 545 546 - 547 - 548 - 549 549 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 550 550 551 - 552 552 [[image:image-20220527094556-31.png]] 553 553 554 554 Network Structure 555 555 556 - 557 557 * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]]