Summary

Details

Page properties
Content
... ... @@ -1,6 +1,4 @@
1 -(% class="wikigeneratedid" %)
2 -*
3 -** Table of** **Contents:
1 +**Table of Contents:**
4 4  
5 5  {{toc/}}
6 6  
... ... @@ -31,12 +31,14 @@
31 31  Connection
32 32  
33 33  
34 -Related documents:
32 +(% style="color:blue" %)**Related documents:**
35 35  
36 -* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure
37 -* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
34 +* System Structure:  [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
35 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
38 38  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
39 39  
38 +
39 +
40 40  == **1.2 Example 2: Connect to Pulse Counter** ==
41 41  
42 42  
... ... @@ -54,11 +54,15 @@
54 54  Connection
55 55  
56 56  
57 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
57 +(% style="color:blue" %)**Related documents:**
58 +
59 +* Configure Document:  [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
58 58  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
59 59  
62 +
60 60  == **1.3 Example3: Use RS485-LN with energy meters** ==
61 61  
65 +
62 62  === **1.3.1 OverView** ===
63 63  
64 64  
... ... @@ -77,7 +77,7 @@
77 77  
78 78  
79 79  (((
80 -**How to connect with Energy Meter:**
84 +(% style="color:blue" %)**How to connect with Energy Meter:**
81 81  
82 82  
83 83  )))
... ... @@ -107,12 +107,12 @@
107 107  Connection2
108 108  
109 109  
110 -
111 111  [[image:image-20220527092555-7.png]]
112 112  
113 113  Connection3
114 114  
115 115  
119 +
116 116  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
117 117  
118 118  
... ... @@ -159,6 +159,7 @@
159 159  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
160 160  
161 161  
166 +
162 162  ==== **1.3.3.1 via AT COMMAND** ====
163 163  
164 164  
... ... @@ -214,7 +214,7 @@
214 214  (((
215 215  (% style="color:blue" %)**Example**:
216 216  
217 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
222 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
218 218  )))
219 219  
220 220  (((
... ... @@ -228,7 +228,7 @@
228 228  )))
229 229  
230 230  (((
231 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
236 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
232 232  )))
233 233  
234 234  (((
... ... @@ -242,7 +242,7 @@
242 242  )))
243 243  
244 244  (((
245 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
250 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
246 246  )))
247 247  
248 248  (((
... ... @@ -270,6 +270,7 @@
270 270  AT COMMAND
271 271  
272 272  
278 +
273 273  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
274 274  
275 275  
... ... @@ -369,6 +369,7 @@
369 369  DOWNLINK
370 370  
371 371  
378 +
372 372  === **1.3.4 How to configure and output commands for RS485 to USB** ===
373 373  
374 374  (((
... ... @@ -426,6 +426,7 @@
426 426  USB
427 427  
428 428  
436 +
429 429  === **1.3.5 How to configure multiple devices and modify device addresses** ===
430 430  
431 431  
... ... @@ -500,7 +500,7 @@
500 500  [[image:image-20220601142607-4.png]]
501 501  
502 502  
503 -**PAYLOAD:01 08 DF 43 62**
511 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
504 504  
505 505  * 08 DF is the valid value of the meter with device address 02.
506 506  * 43 62 is the valid value of the meter with device address 01.
... ... @@ -520,7 +520,7 @@
520 520  Connection
521 521  
522 522  
523 -* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
531 +* Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
524 524  
525 525  
526 526  
... ... @@ -530,22 +530,25 @@
530 530  
531 531  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
532 532  
533 -* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
534 -* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
541 +* Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
542 +* Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
535 535  
536 536  
537 537  
538 538  
539 -== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
547 +== 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
540 540  
549 +
541 541  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
542 542  
543 -* [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
552 +* Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
544 544  
545 -== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
554 +== 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
546 546  
556 +
547 547  [[image:image-20220527094556-31.png]]
548 548  
549 549  Network Structure
550 550  
561 +
551 551  * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]]