Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% class="wikigeneratedid" %) 2 -* 2 +* 3 3 ** Table of** **Contents: 4 4 5 5 {{toc/}} ... ... @@ -214,7 +214,7 @@ 214 214 ((( 215 215 (% style="color:blue" %)**Example**: 216 216 217 -CMD1: 217 +CMD1:Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 218 218 ))) 219 219 220 220 ((( ... ... @@ -246,7 +246,7 @@ 246 246 ))) 247 247 248 248 ((( 249 -RETURN3: 249 +RETURN3:01 03 04 00 00 00 44 FA 00(return data) 250 250 ))) 251 251 252 252 ((( ... ... @@ -265,6 +265,7 @@ 265 265 (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 266 266 267 267 268 + 268 268 [[image:image-20220601143642-2.png]] 269 269 270 270 AT COMMAND ... ... @@ -295,7 +295,7 @@ 295 295 ))) 296 296 297 297 ((( 298 - (% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.299 +Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 299 299 ))) 300 300 301 301 ((( ... ... @@ -333,7 +333,7 @@ 333 333 ((( 334 334 335 335 336 -(% style="color:b lue" %)**Example:**337 +(% style="color:#4f81bd" %)**Example:** 337 337 ))) 338 338 339 339 ((( ... ... @@ -389,8 +389,6 @@ 389 389 390 390 ((( 391 391 check digit: Even 392 - 393 - 394 394 ))) 395 395 396 396 [[image:image-20220527093708-21.png]] ... ... @@ -407,18 +407,14 @@ 407 407 408 408 ((( 409 409 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 410 - 411 - 412 412 ))) 413 413 414 414 ((( 415 -(% style="color:b lue" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4412 +(% style="color:#4f81bd" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4 416 416 ))) 417 417 418 418 ((( 419 419 output:01 03 04 00 00 00 42 7A 02 420 - 421 - 422 422 ))) 423 423 424 424 [[image:image-20220527093821-23.png]] ... ... @@ -428,7 +428,6 @@ 428 428 429 429 === **1.3.5 How to configure multiple devices and modify device addresses** === 430 430 431 - 432 432 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 433 433 434 434 ((( ... ... @@ -440,7 +440,7 @@ 440 440 [[image:image-20220601142044-1.png]] 441 441 442 442 443 - (% style="color:blue" %)**Example**(%%):437 +**Example**:These two meters are examples of setting parameters and device addresses. 444 444 445 445 [[image:image-20220527093950-25.png]] 446 446