Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% class="wikigeneratedid" %) 2 - **Contents:** 2 + ** Table of** **Contents:** 3 3 4 4 {{toc/}} 5 5 ... ... @@ -10,11 +10,13 @@ 10 10 11 11 = **1. Introduction** = 12 12 13 + 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 16 == **1.1 Example 1: Connect to Leak relay and VFD** == 17 17 19 + 18 18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 19 19 20 20 [[image:image-20220527091852-1.png]] ... ... @@ -35,10 +35,14 @@ 35 35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 36 36 37 37 40 + 41 + 38 38 == **1.2 Example 2: Connect to Pulse Counter** == 39 39 44 + 40 40 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 41 41 47 + 42 42 [[image:image-20220527092058-3.png]] 43 43 44 44 Connection ... ... @@ -50,11 +50,12 @@ 50 50 Connection 51 51 52 52 53 -* [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] :Configure Document59 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 54 54 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 55 55 56 -== == 57 57 63 + 64 + 58 58 == **1.3 Example3: Use RS485-LN with energy meters** == 59 59 60 60 === **1.3.1 OverView** === ... ... @@ -332,7 +332,7 @@ 332 332 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 333 333 ))) 334 334 335 -[[image:image-20220 527093430-16.png]]342 +[[image:image-20220601144149-6.png]] 336 336 337 337 DOWNLINK 338 338 ... ... @@ -344,7 +344,7 @@ 344 344 345 345 346 346 347 -[[image:image-20220 527093530-18.png]]354 +[[image:image-20220601144053-5.png]] 348 348 349 349 DOWNLINK 350 350 ... ... @@ -429,6 +429,7 @@ 429 429 430 430 [[image:image-20220527093950-25.png]] 431 431 439 + 432 432 [[image:image-20220527094028-26.png]] 433 433 434 434 ((( ... ... @@ -486,6 +486,7 @@ 486 486 * 08 DF is the valid value of the meter with device address 02. 487 487 * 43 62 is the valid value of the meter with device address 01. 488 488 497 + 489 489 == 1.4 Example 4: Circuit Breaker Remote Open Close == 490 490 491 491 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -504,7 +504,6 @@ 504 504 505 505 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 506 506 507 - 508 508 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 509 509 510 510 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -511,7 +511,6 @@ 511 511 512 512 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 513 513 514 - 515 515 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 516 516 517 517 [[image:image-20220527094556-31.png]]