Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,12 +8,12 @@ 8 8 9 9 10 10 11 -= **1. Introduction**=11 += 1. Introduction = 12 12 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 -== **1.1 Example 1: Connect to Leak relay and VFD**==16 +== 1.1 Example 1: Connect to Leak relay and VFD == 17 17 18 18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 19 19 ... ... @@ -34,9 +34,8 @@ 34 34 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 35 35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 36 36 37 +== 1.2 Example 2: Connect to Pulse Counter == 37 37 38 -== **1.2 Example 2: Connect to Pulse Counter** == 39 - 40 40 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 41 41 42 42 [[image:image-20220527092058-3.png]] ... ... @@ -53,9 +53,9 @@ 53 53 54 54 == == 55 55 56 -== **1.3 Example3: Use RS485-LN with energy meters**==55 +== 1.3 Example3: Use RS485-LN with energy meters == 57 57 58 -=== **1.3.1 OverView**===57 +=== 1.3.1 OverView === 59 59 60 60 ((( 61 61 **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. ... ... @@ -104,7 +104,7 @@ 104 104 Connection3 105 105 106 106 107 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands**===106 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 108 108 109 109 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 110 110 ... ... @@ -492,6 +492,8 @@ 492 492 493 493 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 494 494 494 + 495 + 495 495 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 496 496 497 497 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -498,6 +498,8 @@ 498 498 499 499 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 500 500 502 + 503 + 501 501 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 502 502 503 503 [[image:image-20220527094556-31.png]]