<
From version < 41.9 >
edited by Xiaoling
on 2022/05/31 09:39
To version < 40.2 >
edited by Xiaoling
on 2022/05/27 09:55
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,17 +3,12 @@
3 3  
4 4  {{toc/}}
5 5  
6 += 1. Introduction =
6 6  
7 -
8 -
9 -
10 -
11 -= **1. Introduction** =
12 -
13 13  This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
14 14  
15 15  
16 -== **1.1 Example 1: Connect to Leak relay and VFD** ==
11 +== 1.1 Example 1: Connect to Leak relay and VFD ==
17 17  
18 18  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
19 19  
... ... @@ -35,7 +35,7 @@
35 35  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
36 36  
37 37  
38 -== **1.2 Example 2: Connect to Pulse Counter** ==
33 +== 1.2 Example 2: Connect to Pulse Counter ==
39 39  
40 40  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
41 41  
... ... @@ -53,9 +53,9 @@
53 53  
54 54  == ==
55 55  
56 -== **1.3 Example3: Use RS485-LN with energy meters** ==
51 +== 1.3 Example3: Use RS485-LN with energy meters ==
57 57  
58 -=== **1.3.1 OverView** ===
53 +=== 1.3.1 OverView ===
59 59  
60 60  (((
61 61  **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.
... ... @@ -104,7 +104,7 @@
104 104  Connection3
105 105  
106 106  
107 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
102 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands ===
108 108  
109 109  If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter.
110 110  
... ... @@ -143,12 +143,12 @@
143 143  
144 144  )))
145 145  
146 -=== **1.3.3 How to configure RS485-LN and parse output commands** ===
141 +=== 1.3.3 How to configure RS485-LN and parse output commands ===
147 147  
148 148  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
149 149  
150 150  
151 -==== **1.3.3.1 via AT COMMAND:** ====
146 +==== 1.3.3.1 via AT COMMAND: ====
152 152  
153 153  First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct.
154 154  
... ... @@ -255,7 +255,7 @@
255 255  AT COMMAND
256 256  
257 257  
258 -==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
253 +==== 1.3.3.2 via LoRaWAN DOWNLINK ====
259 259  
260 260  [[image:image-20220527093358-15.png]]
261 261  
... ... @@ -347,7 +347,7 @@
347 347  DOWNLINK
348 348  
349 349  
350 -=== **1.3.4 How to configure and output commands for RS485 to USB** ===
345 +=== 1.3.4 How to configure and output commands for RS485 to USB ===
351 351  
352 352  (((
353 353  This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN.
... ... @@ -396,7 +396,7 @@
396 396  USB
397 397  
398 398  
399 -=== **1.3.5 How to configure multiple devices and modify device addresses** ===
394 +=== 1.3.5 How to configure multiple devices and modify device addresses ===
400 400  
401 401  If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01.
402 402  
... ... @@ -471,7 +471,6 @@
471 471  * 43 62 is the valid value of the meter with device address 01.
472 472  
473 473  
474 -
475 475  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
476 476  
477 477  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
... ... @@ -483,7 +483,6 @@
483 483  * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
484 484  
485 485  
486 -
487 487  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
488 488  
489 489  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
... ... @@ -492,6 +492,7 @@
492 492  
493 493  * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
494 494  
488 +
495 495  == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
496 496  
497 497  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
... ... @@ -498,6 +498,7 @@
498 498  
499 499  * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
500 500  
495 +
501 501  == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
502 502  
503 503  [[image:image-20220527094556-31.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0