From version < 41.8 >
edited by Xiaoling
on 2022/05/31 09:39
To version < 41.12 >
edited by Xiaoling
on 2022/06/01 14:12
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -35,6 +35,7 @@
35 35  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
36 36  
37 37  
38 +
38 38  == **1.2 Example 2: Connect to Pulse Counter** ==
39 39  
40 40  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
... ... @@ -44,10 +44,12 @@
44 44  Connection
45 45  
46 46  
48 +
47 47  [[image:image-20220527092146-4.png]]
48 48  
49 49  Connection
50 50  
53 +
51 51  * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document
52 52  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
53 53  
... ... @@ -471,7 +471,6 @@
471 471  * 43 62 is the valid value of the meter with device address 01.
472 472  
473 473  
474 -
475 475  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
476 476  
477 477  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
... ... @@ -482,6 +482,7 @@
482 482  
483 483  * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
484 484  
487 +
485 485  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
486 486  
487 487  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0