Last modified by Karry Zhuang on 2024/07/11 11:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 16 added, 0 removed)
- image-20220601142044-1.png
- image-20220601142354-2.png
- image-20220601142452-3.png
- image-20220601142607-4.png
- image-20220601142805-5.png
- image-20220601142936-6.png
- image-20220601143046-7.png
- image-20220601143115-8.png
- image-20220601143201-9.png
- image-20220601143257-10.png
- image-20220601143519-1.png
- image-20220601143642-2.png
- image-20220601143803-3.png
- image-20220601143921-4.png
- image-20220601144053-5.png
- image-20220601144149-6.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -1,5 +1,4 @@ 1 -(% class="wikigeneratedid" %) 2 - **Contents:** 1 +**Table of Contents:** 3 3 4 4 {{toc/}} 5 5 ... ... @@ -10,67 +10,83 @@ 10 10 11 11 = 1. Introduction = 12 12 12 + 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 16 == 1.1 Example 1: Connect to Leak relay and VFD == 17 17 18 + 18 18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 19 19 20 -[[image:image-20220527091852-1.png]] 21 21 22 - Connection22 +[[image:image-20220527091852-1.png||height="547" width="994"]] 23 23 24 +**Connection** 24 24 25 25 27 + 26 26 [[image:image-20220527091942-2.png]](% style="display:none" %) 27 27 28 -Connection 30 +**Connection** 29 29 30 30 31 -Related documents: 33 +(% style="color:blue" %)**Related documents:** 32 32 33 -* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure 34 -* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 35 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 36 + 37 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 38 + 35 35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 36 36 37 37 == 1.2 Example 2: Connect to Pulse Counter == 38 38 43 + 39 39 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 40 40 41 -[[image:image-20220527092058-3.png]] 42 42 43 - Connection47 +[[image:image-20220527092058-3.png||height="552" width="905"]] 44 44 49 +**Connection** 45 45 46 -[[image:image-20220527092146-4.png]] 47 47 48 -Connection 49 49 50 -* [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 51 -* [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 53 +[[image:image-20220527092146-4.png||height="507" width="906"]] 52 52 53 - == ==55 +**Connection** 54 54 55 -== 1.3 Example3: Use RS485-LN with energy meters == 56 56 58 +(% style="color:blue" %)**Related documents:** 59 + 60 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 61 + 62 +* [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 63 + 64 +== 1.3 Example 3: Use RS485-LN with energy meters == 65 + 57 57 === 1.3.1 OverView === 58 58 68 + 59 59 ((( 60 -**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 70 +(% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.** 61 61 ))) 62 62 63 63 ((( 64 64 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 75 + 76 + 65 65 ))) 66 66 67 67 [[image:image-20220527092419-5.png]] 68 68 69 -Connection1 81 +**Connection1** 70 70 71 71 84 + 72 72 ((( 73 -How to connect with Energy Meter: 86 +(% style="color:blue" %)**How to connect with Energy Meter:** 87 + 88 + 74 74 ))) 75 75 76 76 ((( ... ... @@ -82,114 +82,124 @@ 82 82 ))) 83 83 84 84 ((( 85 -Power Source VIN to RS485-LN VIN+ 100 +Power Source **VIN** to RS485-LN **VIN+** 86 86 ))) 87 87 88 88 ((( 89 -Power Source GND to RS485-LN VIN- 104 +Power Source **GND** to RS485-LN **VIN-** 90 90 ))) 91 91 92 92 ((( 93 93 Once there is power, the RS485-LN will be on. 109 + 110 + 94 94 ))) 95 95 96 96 [[image:image-20220527092514-6.png]] 97 97 98 -Connection2 115 +**Connection2** 99 99 100 100 118 + 101 101 [[image:image-20220527092555-7.png]] 102 102 103 -Connection3 121 +**Connection3** 104 104 105 105 106 106 === 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 107 107 126 + 108 108 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 109 109 110 -[[image:image-20220 527092629-8.png]]129 +[[image:image-20220601143257-10.png]] 111 111 112 112 113 -(% class="box infomessage" %) 114 -((( 115 -**Example:** AT+COMMAND1=01 03 00 00 00 01 84 0A 116 -))) 132 +(% style="color:blue" %)**Example:**(%%) AT+COMMAND1=01 03 00 00 00 01 84 0A 117 117 118 118 * The first byte : slave address code (=001~247) 135 + 119 119 * The second byte : read register value function code 137 + 120 120 * 3rd and 4th bytes: start address of register to be read 139 + 121 121 * 5th and 6th bytes: Number of registers to read 141 + 122 122 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6. 123 123 124 124 ((( 145 + 146 + 147 + 125 125 How to parse the reading of the return command of the parameter: 126 -))) 127 127 128 -(% class="box infomessage" %) 129 -((( 130 -**Example:** RETURN1:01 03 02 08 FD 7E 05 150 +(% style="color:blue" %)**Example:**(%%) RETURN1:01 03 02 08 FD 7E 05 131 131 ))) 132 132 133 133 * The first byte ARD: slave address code (=001~254) 154 + 134 134 * The second byte: Return to read function code 156 + 135 135 * 3rd byte: total number of bytes 158 + 136 136 * 4th~5th bytes: register data 160 + 137 137 * The 6th and 7th bytes: CRC16 checksum 162 + 138 138 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 139 139 140 -(% class="wikigeneratedid" %) 141 -((( 142 - 143 -))) 165 +=== 1.3.3 How to configure RS485-LN and parse output commands === 144 144 145 -=== **1.3.3 How to configure RS485-LN and parse output commands** === 146 146 147 147 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 148 148 149 149 150 -==== **1.3.3.1 via AT COMMAND :** ====171 +==== **1.3.3.1 via AT COMMAND** ==== 151 151 152 -First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct. 153 153 174 +First, we can use (% style="color:blue" %)**AT+CFGDEV**(%%) to get the return value, and we can also judge whether the input parameters are correct. 175 + 154 154 ((( 155 155 If the configured parameters and commands are incorrect, the return value is not obtained. 178 + 179 + 156 156 ))) 157 157 158 -[[image:image-20220 527092748-9.png]]182 +[[image:image-20220601143201-9.png]] 159 159 160 -AT COMMAND 184 +**AT COMMAND** 161 161 162 162 163 163 (% class="box infomessage" %) 164 164 ((( 165 - AT+DATACUTx 189 + (% _mstmutation="1" %)**AT+DATACUTx **(%%): This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 166 166 ))) 167 167 168 -a: length for the return of AT+COMMAND 192 +a: length for the return of AT+COMMAND 169 169 170 -b:1: grab valid value by byte, max 6 bytes .2: grab valid value by bytes section, max 3 sections.194 +b: 1: grab valid value by byte, max 6 bytes; 2: grab valid value by bytes section, max 3 sections. 171 171 172 -c: define the position for valid value. 196 +c: define the position for valid value. 173 173 174 -[[image:image-20220 527092936-10.png]]198 +[[image:image-20220601143115-8.png]] 175 175 176 -AT COMMAND 200 +**AT COMMAND** 177 177 178 178 203 + 179 179 PAYLOAD is available after the valid value is intercepted. 180 180 206 +[[image:image-20220601143046-7.png]] 181 181 182 - [[image:image-20220527093059-11.png]]208 +**AT COMMAND** 183 183 184 -AT COMMAND 185 185 186 186 187 187 You can get configured PAYLOAD on TTN. 188 188 189 -[[image:image-20220 527093133-12.png]]214 +[[image:image-20220601143519-1.png]] 190 190 191 191 ((( 192 -AT COMMAND 217 +**AT COMMAND** 193 193 ))) 194 194 195 195 ((( ... ... @@ -197,77 +197,79 @@ 197 197 ))) 198 198 199 199 ((( 200 -(% style="color: #4f81bd" %)**Example**:225 +(% style="color:blue" %)**Example**: 201 201 202 -CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 227 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 203 203 ))) 204 204 205 205 ((( 206 -RETURN1:01 03 02 00 02 39 85 00 00(return data) 231 +RETURN1: 01 03 02 00 02 39 85 00 00(return data) 207 207 ))) 208 208 209 209 ((( 210 -AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 235 +AT+DATACUT1: 9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 211 211 212 212 213 213 ))) 214 214 215 215 ((( 216 -CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1 241 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 217 217 ))) 218 218 219 219 ((( 220 -RETURN2:01 03 02 08 DC BE 1D(return data) 245 +RETURN2: 01 03 02 08 DC BE 1D(return data) 221 221 ))) 222 222 223 223 ((( 224 -AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 249 +AT+DATACUT2: 7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 225 225 226 226 227 227 ))) 228 228 229 229 ((( 230 -CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 255 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 231 231 ))) 232 232 233 233 ((( 234 -RETURN3:01 03 04 00 00 00 44 FA 00(return data) 259 +RETURN3: 01 03 04 00 00 00 44 FA 00(return data) 235 235 ))) 236 236 237 237 ((( 238 -AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 263 +AT+DATACUT3: 9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 239 239 ))) 240 240 241 241 ((( 242 -Payload:01 00 02 39 85 08 DC 00 00 00 44 267 +Payload: 01 00 02 39 85 08 DC 00 00 00 44 243 243 ))) 244 244 245 -[[image:image-20220 527093204-13.png]]270 +[[image:image-20220601142936-6.png]] 246 246 247 247 AT COMMAND 248 248 249 249 250 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 251 251 252 - [[image:image-20220527093251-14.png]]276 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 253 253 278 + 279 +[[image:image-20220601143642-2.png]] 280 + 254 254 AT COMMAND 255 255 256 256 284 + 257 257 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 258 258 287 + 259 259 [[image:image-20220527093358-15.png]] 260 260 261 261 ((( 262 -DOWNLINK 291 +**DOWNLINK** 263 263 ))) 264 264 265 -((( 266 - 267 -))) 268 268 295 + 269 269 ((( 270 -(% style="color: #4f81bd" %)**Type Code 0xAF**297 +(% style="color:blue" %)**Type Code 0xAF** 271 271 ))) 272 272 273 273 ((( ... ... @@ -278,7 +278,7 @@ 278 278 ))) 279 279 280 280 ((( 281 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 308 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 282 282 ))) 283 283 284 284 ((( ... ... @@ -313,8 +313,9 @@ 313 313 will execute an uplink after got this command. 314 314 ))) 315 315 343 + 316 316 ((( 317 -(% style="color: #4f81bd" %)**Example:**345 +(% style="color:blue" %)**Example:** 318 318 ))) 319 319 320 320 ((( ... ... @@ -321,33 +321,38 @@ 321 321 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 322 322 ))) 323 323 324 -[[image:image-20220 527093430-16.png]]352 +[[image:image-20220601144149-6.png]] 325 325 326 -DOWNLINK 354 +**DOWNLINK** 327 327 328 328 329 -[[image:image-20220527093508-17.png]] 330 330 331 - DOWNLINK358 +[[image:image-20220601143803-3.png]] 332 332 360 +**DOWNLINK** 333 333 334 -[[image:image-20220527093530-18.png]] 335 335 336 -DOWNLINK 337 337 364 +[[image:image-20220601144053-5.png]] 338 338 339 - [[image:image-20220527093607-19.png]]366 +**DOWNLINK** 340 340 341 -DOWNLINK 342 342 343 343 344 -[[image:image-20220 527093628-20.png]]370 +[[image:image-20220601143921-4.png]] 345 345 346 -DOWNLINK 347 - 372 +**DOWNLINK** 348 348 349 -=== **1.3.4 How to configure and output commands for RS485 to USB** === 350 350 375 + 376 +[[image:image-20220601142805-5.png]] 377 + 378 +**DOWNLINK** 379 + 380 + 381 +=== 1.3.4 How to configure and output commands for RS485 to USB === 382 + 383 + 351 351 ((( 352 352 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN. 353 353 ))) ... ... @@ -366,37 +366,45 @@ 366 366 367 367 ((( 368 368 check digit: Even 402 + 403 + 369 369 ))) 370 370 371 371 [[image:image-20220527093708-21.png]] 372 372 373 -USB 408 +**USB** 374 374 375 375 411 + 376 376 [[image:image-20220527093747-22.png]] 377 377 378 -USB 414 +**USB** 379 379 380 380 417 + 381 381 ((( 382 382 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 383 383 ))) 384 384 385 385 ((( 386 -(% style="color: #4f81bd" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4423 +(% style="color:blue" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4 387 387 ))) 388 388 389 389 ((( 390 390 output:01 03 04 00 00 00 42 7A 02 428 + 429 + 391 391 ))) 392 392 393 393 [[image:image-20220527093821-23.png]] 394 394 395 -USB 434 +**USB** 396 396 397 397 398 -=== **1.3.5 How to configure multiple devices and modify device addresses** === 399 399 438 +=== 1.3.5 How to configure multiple devices and modify device addresses === 439 + 440 + 400 400 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 401 401 402 402 ((( ... ... @@ -405,15 +405,18 @@ 405 405 ))) 406 406 ))) 407 407 408 -[[image:image-20220 527093849-24.png]]449 +[[image:image-20220601142044-1.png]] 409 409 410 410 411 -**Example**:These two meters are examples of setting parameters and device addresses. 452 +(% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 412 412 454 + 413 413 [[image:image-20220527093950-25.png]] 414 414 457 + 415 415 [[image:image-20220527094028-26.png]] 416 416 460 + 417 417 ((( 418 418 ((( 419 419 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. ... ... @@ -422,7 +422,7 @@ 422 422 423 423 ((( 424 424 ((( 425 -We can use AT+CFGDEV to set the device address. 469 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address. 426 426 ))) 427 427 ))) 428 428 ... ... @@ -432,16 +432,17 @@ 432 432 ))) 433 433 ))) 434 434 435 -[[image:image-20220 527094100-27.png]]479 +[[image:image-20220601142354-2.png]] 436 436 481 + 437 437 (% class="box infomessage" %) 438 438 ((( 439 439 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** 440 440 ))) 441 441 442 -* 01:device adaress 487 +* 01: device adaress 443 443 444 -* 10:function code 489 +* 10: function code 445 445 446 446 * 00 61:Register address 447 447 ... ... @@ -459,50 +459,68 @@ 459 459 460 460 Its default device address is 01, and the following are the parameters for configuring two energy meters. 461 461 462 -[[image:image-20220 527094150-28.png]]507 +[[image:image-20220601142452-3.png]] 463 463 464 464 465 -[[image:image-20220 527094224-29.png]]510 +[[image:image-20220601142607-4.png]] 466 466 467 -**PAYLOAD:01 08 DF 43 62** 468 468 513 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62** 514 + 469 469 * 08 DF is the valid value of the meter with device address 02. 470 470 * 43 62 is the valid value of the meter with device address 01. 471 471 518 +(% style="display:none" %) (%%) 472 472 473 473 474 474 == 1.4 Example 4: Circuit Breaker Remote Open Close == 475 475 476 -This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: 477 477 478 - [[image:image-20220527094330-30.png]]524 +This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. 479 479 480 - Connection526 +The structure is like below: 481 481 482 - *[[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]: Configure Documen528 +[[image:image-20220527094330-30.png]] 483 483 530 +**Connection** 484 484 485 485 533 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 534 + 486 486 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 487 487 537 + 488 488 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 489 489 490 -* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf ]] : Configure Document ForRS485-BL540 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 491 491 492 -* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf ]] : Configure Documentfor RS485-LN542 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 493 493 544 +== 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 494 494 495 495 496 -== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 497 - 498 498 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 499 499 500 -* [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf ]] : Configure Document ForRS485-LN549 +* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 501 501 502 -== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 551 +== 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 503 503 553 + 504 504 [[image:image-20220527094556-31.png]] 505 505 556 + 506 506 Network Structure 507 507 508 508 * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]] 560 + 561 +== 1.8 Example 8: This sketch is supposed to test Dragino RS485-BL (Modbus master), using an Arduino UNO as a Modbus slave. == 562 + 563 +This sketch uses 4 registers: some of them can be set by Dragino with a command, another is used to store value from a DS18B20 temperature sensor, or a random generated number. All data is 16bit uint, but the sketch shows also how to represent booleans and negative numbers. 564 + 565 +In the next days I will be adding more documentation, but I think it already explains users how to build their own modbus sensor to pair with Dragino RS485-BL. 566 + 567 +This is released the code under GNU LGPL licence on Github: 568 + 569 +[[https:~~/~~/github.com/zorbaproject/ArduinoModbusForDraginoRS485>>url:https://github.com/zorbaproject/ArduinoModbusForDraginoRS485]] 570 + 571 +
- image-20220601142044-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.7 KB - Content
- image-20220601142354-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.8 KB - Content
- image-20220601142452-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.1 KB - Content
- image-20220601142607-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.9 KB - Content
- image-20220601142805-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- image-20220601142936-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.7 KB - Content
- image-20220601143046-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.2 KB - Content
- image-20220601143115-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.9 KB - Content
- image-20220601143201-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content
- image-20220601143257-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- image-20220601143519-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- image-20220601143642-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.4 KB - Content
- image-20220601143803-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content
- image-20220601143921-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- image-20220601144053-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.1 KB - Content
- image-20220601144149-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content