Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 16 added, 0 removed)
- image-20220601142044-1.png
- image-20220601142354-2.png
- image-20220601142452-3.png
- image-20220601142607-4.png
- image-20220601142805-5.png
- image-20220601142936-6.png
- image-20220601143046-7.png
- image-20220601143115-8.png
- image-20220601143201-9.png
- image-20220601143257-10.png
- image-20220601143519-1.png
- image-20220601143642-2.png
- image-20220601143803-3.png
- image-20220601143921-4.png
- image-20220601144053-5.png
- image-20220601144149-6.png
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,4 @@ 1 -(% class="wikigeneratedid" %) 2 - **Contents:** 1 +**Table of Contents:** 3 3 4 4 {{toc/}} 5 5 ... ... @@ -10,13 +10,17 @@ 10 10 11 11 = **1. Introduction** = 12 12 12 + 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 + 16 16 == **1.1 Example 1: Connect to Leak relay and VFD** == 17 17 19 + 18 18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 19 19 22 + 20 20 [[image:image-20220527091852-1.png]] 21 21 22 22 Connection ... ... @@ -28,10 +28,10 @@ 28 28 Connection 29 29 30 30 31 -Related documents: 34 +(% style="color:blue" %)**Related documents:** 32 32 33 -* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/ ]] : SystemStructure34 -* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/ ]] : Explanationon howto integrate toNode-red andtothe MobilePhone,andwith link to the Github code.36 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 37 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 35 35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 36 36 37 37 ... ... @@ -38,8 +38,10 @@ 38 38 39 39 == **1.2 Example 2: Connect to Pulse Counter** == 40 40 44 + 41 41 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 42 42 47 + 43 43 [[image:image-20220527092058-3.png]] 44 44 45 45 Connection ... ... @@ -51,21 +51,27 @@ 51 51 Connection 52 52 53 53 54 -* [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 59 +(% style="color:blue" %)**Related documents:** 60 + 61 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 55 55 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 56 56 57 -== == 58 58 65 + 59 59 == **1.3 Example3: Use RS485-LN with energy meters** == 60 60 68 + 61 61 === **1.3.1 OverView** === 62 62 71 + 63 63 ((( 64 -**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 73 +(% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.** 65 65 ))) 66 66 67 67 ((( 68 68 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 78 + 79 + 69 69 ))) 70 70 71 71 [[image:image-20220527092419-5.png]] ... ... @@ -75,7 +75,9 @@ 75 75 76 76 77 77 ((( 78 -How to connect with Energy Meter: 89 +(% style="color:blue" %)**How to connect with Energy Meter:** 90 + 91 + 79 79 ))) 80 80 81 81 ((( ... ... @@ -96,6 +96,8 @@ 96 96 97 97 ((( 98 98 Once there is power, the RS485-LN will be on. 112 + 113 + 99 99 ))) 100 100 101 101 [[image:image-20220527092514-6.png]] ... ... @@ -109,17 +109,16 @@ 109 109 Connection3 110 110 111 111 127 + 112 112 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 113 113 130 + 114 114 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 115 115 116 -[[image:image-20220 527092629-8.png]]133 +[[image:image-20220601143257-10.png]] 117 117 118 118 119 -(% class="box infomessage" %) 120 -((( 121 -**Example:** AT+COMMAND1=01 03 00 00 00 01 84 0A 122 -))) 136 +(% style="color:blue" %)**Example:**(%%) AT+COMMAND1=01 03 00 00 00 01 84 0A 123 123 124 124 * The first byte : slave address code (=001~247) 125 125 * The second byte : read register value function code ... ... @@ -128,12 +128,12 @@ 128 128 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6. 129 129 130 130 ((( 145 + 146 + 147 + 131 131 How to parse the reading of the return command of the parameter: 132 -))) 133 133 134 -(% class="box infomessage" %) 135 -((( 136 -**Example:** RETURN1:01 03 02 08 FD 7E 05 150 +(% style="color:blue" %)**Example:**(%%) RETURN1:01 03 02 08 FD 7E 05 137 137 ))) 138 138 139 139 * The first byte ARD: slave address code (=001~254) ... ... @@ -146,22 +146,30 @@ 146 146 (% class="wikigeneratedid" %) 147 147 ((( 148 148 163 + 164 + 165 + 149 149 ))) 150 150 151 151 === **1.3.3 How to configure RS485-LN and parse output commands** === 152 152 170 + 153 153 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 154 154 155 155 156 -==== **1.3.3.1 via AT COMMAND:** ==== 157 157 158 - First,wecanuse **AT+CFGDEV**to get the return value, and we can also judge whether the input parameters are correct.175 +==== **1.3.3.1 via AT COMMAND** ==== 159 159 177 + 178 +First, we can use (% style="color:blue" %)**AT+CFGDEV**(%%) to get the return value, and we can also judge whether the input parameters are correct. 179 + 160 160 ((( 161 161 If the configured parameters and commands are incorrect, the return value is not obtained. 182 + 183 + 162 162 ))) 163 163 164 -[[image:image-20220 527092748-9.png]]186 +[[image:image-20220601143201-9.png]] 165 165 166 166 AT COMMAND 167 167 ... ... @@ -168,7 +168,7 @@ 168 168 169 169 (% class="box infomessage" %) 170 170 ((( 171 - AT+DATACUTx 193 + (% _mstmutation="1" %)**AT+DATACUTx **(%%): This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 172 172 ))) 173 173 174 174 a: length for the return of AT+COMMAND ... ... @@ -177,7 +177,7 @@ 177 177 178 178 c: define the position for valid value. 179 179 180 -[[image:image-20220 527092936-10.png]]202 +[[image:image-20220601143115-8.png]] 181 181 182 182 AT COMMAND 183 183 ... ... @@ -186,7 +186,7 @@ 186 186 PAYLOAD is available after the valid value is intercepted. 187 187 188 188 189 -[[image:image-20220 527093059-11.png]]211 +[[image:image-20220601143046-7.png]] 190 190 191 191 AT COMMAND 192 192 ... ... @@ -194,7 +194,7 @@ 194 194 195 195 You can get configured PAYLOAD on TTN. 196 196 197 -[[image:image-20220 527093133-12.png]]219 +[[image:image-20220601143519-1.png]] 198 198 199 199 ((( 200 200 AT COMMAND ... ... @@ -202,70 +202,77 @@ 202 202 203 203 ((( 204 204 227 + 228 + 205 205 ))) 206 206 207 207 ((( 208 -(% style="color: #4f81bd" %)**Example**:232 +(% style="color:blue" %)**Example**: 209 209 210 -CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 234 + 235 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 211 211 ))) 212 212 213 213 ((( 214 -RETURN1:01 03 02 00 02 39 85 00 00(return data) 239 +RETURN1: 01 03 02 00 02 39 85 00 00(return data) 215 215 ))) 216 216 217 217 ((( 218 -AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 243 +AT+DATACUT1: 9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 219 219 220 220 221 221 ))) 222 222 223 223 ((( 224 -CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1 249 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 225 225 ))) 226 226 227 227 ((( 228 -RETURN2:01 03 02 08 DC BE 1D(return data) 253 +RETURN2: 01 03 02 08 DC BE 1D(return data) 229 229 ))) 230 230 231 231 ((( 232 -AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 257 +AT+DATACUT2: 7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 233 233 234 234 235 235 ))) 236 236 237 237 ((( 238 -CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 263 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 239 239 ))) 240 240 241 241 ((( 242 -RETURN3:01 03 04 00 00 00 44 FA 00(return data) 267 +RETURN3: 01 03 04 00 00 00 44 FA 00(return data) 243 243 ))) 244 244 245 245 ((( 246 -AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 271 +AT+DATACUT3: 9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 247 247 ))) 248 248 249 249 ((( 250 -Payload:01 00 02 39 85 08 DC 00 00 00 44 275 +Payload: 01 00 02 39 85 08 DC 00 00 00 44 276 + 277 + 251 251 ))) 252 252 253 -[[image:image-20220 527093204-13.png]]280 +[[image:image-20220601142936-6.png]] 254 254 255 255 AT COMMAND 256 256 257 257 258 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 259 259 286 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 260 260 261 261 262 -[[image:image-20220 527093251-14.png]]289 +[[image:image-20220601143642-2.png]] 263 263 264 264 AT COMMAND 265 265 266 266 294 + 267 267 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 268 268 297 + 269 269 [[image:image-20220527093358-15.png]] 270 270 271 271 ((( ... ... @@ -288,7 +288,9 @@ 288 288 ))) 289 289 290 290 ((( 291 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 320 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 321 + 322 + 292 292 ))) 293 293 294 294 ((( ... ... @@ -326,7 +326,7 @@ 326 326 ((( 327 327 328 328 329 -(% style="color: #4f81bd" %)**Example:**360 +(% style="color:blue" %)**Example:** 330 330 ))) 331 331 332 332 ((( ... ... @@ -333,36 +333,39 @@ 333 333 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 334 334 ))) 335 335 336 -[[image:image-20220 527093430-16.png]]367 +[[image:image-20220601144149-6.png]] 337 337 338 338 DOWNLINK 339 339 340 340 341 341 342 -[[image:image-20220 527093508-17.png]]373 +[[image:image-20220601143803-3.png]] 343 343 344 344 DOWNLINK 345 345 346 346 347 347 348 -[[image:image-20220 527093530-18.png]]379 +[[image:image-20220601144053-5.png]] 349 349 350 350 DOWNLINK 351 351 352 352 353 353 354 -[[image:image-20220 527093607-19.png]]385 +[[image:image-20220601143921-4.png]] 355 355 356 356 DOWNLINK 357 357 358 358 359 -[[image:image-20220527093628-20.png]] 360 360 391 +[[image:image-20220601142805-5.png]] 392 + 361 361 DOWNLINK 362 362 363 363 396 + 364 364 === **1.3.4 How to configure and output commands for RS485 to USB** === 365 365 399 + 366 366 ((( 367 367 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN. 368 368 ))) ... ... @@ -381,6 +381,8 @@ 381 381 382 382 ((( 383 383 check digit: Even 418 + 419 + 384 384 ))) 385 385 386 386 [[image:image-20220527093708-21.png]] ... ... @@ -388,21 +388,27 @@ 388 388 USB 389 389 390 390 427 + 391 391 [[image:image-20220527093747-22.png]] 392 392 393 393 USB 394 394 395 395 433 + 396 396 ((( 397 397 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 436 + 437 + 398 398 ))) 399 399 400 400 ((( 401 -(% style="color: #4f81bd" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4441 +(% style="color:blue" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4 402 402 ))) 403 403 404 404 ((( 405 405 output:01 03 04 00 00 00 42 7A 02 446 + 447 + 406 406 ))) 407 407 408 408 [[image:image-20220527093821-23.png]] ... ... @@ -410,8 +410,10 @@ 410 410 USB 411 411 412 412 455 + 413 413 === **1.3.5 How to configure multiple devices and modify device addresses** === 414 414 458 + 415 415 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 416 416 417 417 ((( ... ... @@ -420,15 +420,17 @@ 420 420 ))) 421 421 ))) 422 422 423 -[[image:image-20220 527093849-24.png]]467 +[[image:image-20220601142044-1.png]] 424 424 425 425 426 -**Example**:These two meters are examples of setting parameters and device addresses. 470 +(% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 427 427 428 428 [[image:image-20220527093950-25.png]] 429 429 474 + 430 430 [[image:image-20220527094028-26.png]] 431 431 477 + 432 432 ((( 433 433 ((( 434 434 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. ... ... @@ -437,7 +437,7 @@ 437 437 438 438 ((( 439 439 ((( 440 -We can use AT+CFGDEV to set the device address. 486 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address. 441 441 ))) 442 442 ))) 443 443 ... ... @@ -447,8 +447,9 @@ 447 447 ))) 448 448 ))) 449 449 450 -[[image:image-20220 527094100-27.png]]496 +[[image:image-20220601142354-2.png]] 451 451 498 + 452 452 (% class="box infomessage" %) 453 453 ((( 454 454 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** ... ... @@ -474,46 +474,52 @@ 474 474 475 475 Its default device address is 01, and the following are the parameters for configuring two energy meters. 476 476 477 -[[image:image-20220 527094150-28.png]]524 +[[image:image-20220601142452-3.png]] 478 478 479 479 480 -[[image:image-20220 527094224-29.png]]527 +[[image:image-20220601142607-4.png]] 481 481 482 -**PAYLOAD:01 08 DF 43 62** 483 483 530 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62** 531 + 484 484 * 08 DF is the valid value of the meter with device address 02. 485 485 * 43 62 is the valid value of the meter with device address 01. 486 486 487 - 488 488 == 1.4 Example 4: Circuit Breaker Remote Open Close == 489 489 490 -This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: 491 491 538 +This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. 539 + 540 +The structure is like below: 541 + 492 492 [[image:image-20220527094330-30.png]] 493 493 494 494 Connection 495 495 496 -* [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 497 497 547 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 498 498 499 499 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 500 500 551 + 501 501 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 502 502 503 -* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf]] : Configure Document For RS485-BL 554 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 555 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 504 504 505 - *[[Connectto SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] :Configure Document forRS485-LN557 +== 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 506 506 507 -== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 508 508 509 509 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 510 510 511 -* [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf ]] : Configure Document ForRS485-LN562 +* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 512 512 513 -== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 564 +== 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 514 514 566 + 515 515 [[image:image-20220527094556-31.png]] 516 516 517 517 Network Structure 518 518 571 + 519 519 * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]]
- image-20220601142044-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.7 KB - Content
- image-20220601142354-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.8 KB - Content
- image-20220601142452-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.1 KB - Content
- image-20220601142607-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.9 KB - Content
- image-20220601142805-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- image-20220601142936-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.7 KB - Content
- image-20220601143046-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.2 KB - Content
- image-20220601143115-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.9 KB - Content
- image-20220601143201-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content
- image-20220601143257-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- image-20220601143519-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- image-20220601143642-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.4 KB - Content
- image-20220601143803-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content
- image-20220601143921-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- image-20220601144053-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.1 KB - Content
- image-20220601144149-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content