Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,12 +8,12 @@ 8 8 9 9 10 10 11 -= **1. Introduction**=11 += 1. Introduction = 12 12 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 -== **1.1 Example 1: Connect to Leak relay and VFD**==16 +== 1.1 Example 1: Connect to Leak relay and VFD == 17 17 18 18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 19 19 ... ... @@ -34,10 +34,8 @@ 34 34 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 35 35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 36 36 37 +== 1.2 Example 2: Connect to Pulse Counter == 37 37 38 - 39 -== **1.2 Example 2: Connect to Pulse Counter** == 40 - 41 41 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 42 42 43 43 [[image:image-20220527092058-3.png]] ... ... @@ -45,20 +45,18 @@ 45 45 Connection 46 46 47 47 48 - 49 49 [[image:image-20220527092146-4.png]] 50 50 51 51 Connection 52 52 53 - 54 54 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 55 55 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 56 56 57 57 == == 58 58 59 -== **1.3 Example3: Use RS485-LN with energy meters**==55 +== 1.3 Example3: Use RS485-LN with energy meters == 60 60 61 -=== **1.3.1 OverView**===57 +=== 1.3.1 OverView === 62 62 63 63 ((( 64 64 **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. ... ... @@ -73,7 +73,6 @@ 73 73 Connection1 74 74 75 75 76 - 77 77 ((( 78 78 How to connect with Energy Meter: 79 79 ))) ... ... @@ -103,13 +103,12 @@ 103 103 Connection2 104 104 105 105 106 - 107 107 [[image:image-20220527092555-7.png]] 108 108 109 109 Connection3 110 110 111 111 112 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands**===106 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 113 113 114 114 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 115 115 ... ... @@ -171,11 +171,11 @@ 171 171 AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 172 172 ))) 173 173 174 -a: 168 +a: length for the return of AT+COMMAND 175 175 176 -b: ;2: grab valid value by bytes section, max 3 sections.170 +b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections. 177 177 178 -c: 172 +c: define the position for valid value. 179 179 180 180 [[image:image-20220527092936-10.png]] 181 181 ... ... @@ -182,7 +182,6 @@ 182 182 AT COMMAND 183 183 184 184 185 - 186 186 PAYLOAD is available after the valid value is intercepted. 187 187 188 188 ... ... @@ -191,7 +191,6 @@ 191 191 AT COMMAND 192 192 193 193 194 - 195 195 You can get configured PAYLOAD on TTN. 196 196 197 197 [[image:image-20220527093133-12.png]] ... ... @@ -257,8 +257,6 @@ 257 257 258 258 (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 259 259 260 - 261 - 262 262 [[image:image-20220527093251-14.png]] 263 263 264 264 AT COMMAND ... ... @@ -324,8 +324,6 @@ 324 324 ))) 325 325 326 326 ((( 327 - 328 - 329 329 (% style="color:#4f81bd" %)**Example:** 330 330 ))) 331 331 ... ... @@ -338,7 +338,6 @@ 338 338 DOWNLINK 339 339 340 340 341 - 342 342 [[image:image-20220527093508-17.png]] 343 343 344 344 DOWNLINK ... ... @@ -483,6 +483,7 @@ 483 483 * 43 62 is the valid value of the meter with device address 01. 484 484 485 485 473 + 486 486 == 1.4 Example 4: Circuit Breaker Remote Open Close == 487 487 488 488 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -494,6 +494,7 @@ 494 494 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 495 495 496 496 485 + 497 497 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 498 498 499 499 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -502,6 +502,8 @@ 502 502 503 503 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 504 504 494 + 495 + 505 505 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 506 506 507 507 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: