<
From version < 41.17 >
edited by Xiaoling
on 2022/06/01 14:15
To version < 41.6 >
edited by Xiaoling
on 2022/05/30 11:26
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,12 +8,12 @@
8 8  
9 9  
10 10  
11 -= **1. Introduction** =
11 += 1. Introduction =
12 12  
13 13  This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
14 14  
15 15  
16 -== **1.1 Example 1: Connect to Leak relay and VFD** ==
16 +== 1.1 Example 1: Connect to Leak relay and VFD ==
17 17  
18 18  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
19 19  
... ... @@ -36,7 +36,7 @@
36 36  
37 37  
38 38  
39 -== **1.2 Example 2: Connect to Pulse Counter** ==
39 +== 1.2 Example 2: Connect to Pulse Counter ==
40 40  
41 41  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
42 42  
... ... @@ -45,20 +45,18 @@
45 45  Connection
46 46  
47 47  
48 -
49 49  [[image:image-20220527092146-4.png]]
50 50  
51 51  Connection
52 52  
53 -
54 54  * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document
55 55  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
56 56  
57 57  == ==
58 58  
59 -== **1.3 Example3: Use RS485-LN with energy meters** ==
57 +== 1.3 Example3: Use RS485-LN with energy meters ==
60 60  
61 -=== **1.3.1 OverView** ===
59 +=== 1.3.1 OverView ===
62 62  
63 63  (((
64 64  **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.
... ... @@ -73,7 +73,6 @@
73 73  Connection1
74 74  
75 75  
76 -
77 77  (((
78 78  How to connect with Energy Meter:
79 79  )))
... ... @@ -103,13 +103,12 @@
103 103  Connection2
104 104  
105 105  
106 -
107 107  [[image:image-20220527092555-7.png]]
108 108  
109 109  Connection3
110 110  
111 111  
112 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
108 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands ===
113 113  
114 114  If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter.
115 115  
... ... @@ -171,11 +171,11 @@
171 171   AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
172 172  )))
173 173  
174 -a:  length for the return of AT+COMMAND
170 +a: length for the return of AT+COMMAND
175 175  
176 -b: 1: grab valid value by byte, max 6 bytes 2: grab valid value by bytes section, max 3 sections.
172 +b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.
177 177  
178 -c:  define the position for valid value.
174 +c: define the position for valid value.
179 179  
180 180  [[image:image-20220527092936-10.png]]
181 181  
... ... @@ -182,7 +182,6 @@
182 182  AT COMMAND
183 183  
184 184  
185 -
186 186  PAYLOAD is available after the valid value is intercepted.
187 187  
188 188  
... ... @@ -191,7 +191,6 @@
191 191  AT COMMAND
192 192  
193 193  
194 -
195 195  You can get configured PAYLOAD on TTN.
196 196  
197 197  [[image:image-20220527093133-12.png]]
... ... @@ -257,8 +257,6 @@
257 257  
258 258  (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
259 259  
260 -
261 -
262 262  [[image:image-20220527093251-14.png]]
263 263  
264 264  AT COMMAND
... ... @@ -499,6 +499,7 @@
499 499  
500 500  * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
501 501  
494 +
502 502  == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
503 503  
504 504  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
... ... @@ -505,6 +505,7 @@
505 505  
506 506  * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
507 507  
501 +
508 508  == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
509 509  
510 510  [[image:image-20220527094556-31.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0