Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,12 +8,12 @@ 8 8 9 9 10 10 11 -= **1. Introduction**=11 += 1. Introduction = 12 12 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 -== **1.1 Example 1: Connect to Leak relay and VFD**==16 +== 1.1 Example 1: Connect to Leak relay and VFD == 17 17 18 18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 19 19 ... ... @@ -36,7 +36,7 @@ 36 36 37 37 38 38 39 -== **1.2 Example 2: Connect to Pulse Counter**==39 +== 1.2 Example 2: Connect to Pulse Counter == 40 40 41 41 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 42 42 ... ... @@ -45,20 +45,18 @@ 45 45 Connection 46 46 47 47 48 - 49 49 [[image:image-20220527092146-4.png]] 50 50 51 51 Connection 52 52 53 - 54 54 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 55 55 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 56 56 57 57 == == 58 58 59 -== **1.3 Example3: Use RS485-LN with energy meters**==57 +== 1.3 Example3: Use RS485-LN with energy meters == 60 60 61 -=== **1.3.1 OverView**===59 +=== 1.3.1 OverView === 62 62 63 63 ((( 64 64 **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. ... ... @@ -73,7 +73,6 @@ 73 73 Connection1 74 74 75 75 76 - 77 77 ((( 78 78 How to connect with Energy Meter: 79 79 ))) ... ... @@ -103,13 +103,12 @@ 103 103 Connection2 104 104 105 105 106 - 107 107 [[image:image-20220527092555-7.png]] 108 108 109 109 Connection3 110 110 111 111 112 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands**===108 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 113 113 114 114 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 115 115 ... ... @@ -171,11 +171,11 @@ 171 171 AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 172 172 ))) 173 173 174 -a: 170 +a: length for the return of AT+COMMAND 175 175 176 -b: ;2: grab valid value by bytes section, max 3 sections.172 +b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections. 177 177 178 -c: 174 +c: define the position for valid value. 179 179 180 180 [[image:image-20220527092936-10.png]] 181 181 ... ... @@ -182,7 +182,6 @@ 182 182 AT COMMAND 183 183 184 184 185 - 186 186 PAYLOAD is available after the valid value is intercepted. 187 187 188 188 ... ... @@ -496,6 +496,7 @@ 496 496 497 497 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 498 498 494 + 499 499 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 500 500 501 501 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -502,6 +502,7 @@ 502 502 503 503 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 504 504 501 + 505 505 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 506 506 507 507 [[image:image-20220527094556-31.png]]