Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 14 added, 0 removed)
- image-20220601142044-1.png
- image-20220601142354-2.png
- image-20220601142452-3.png
- image-20220601142607-4.png
- image-20220601142805-5.png
- image-20220601142936-6.png
- image-20220601143046-7.png
- image-20220601143115-8.png
- image-20220601143201-9.png
- image-20220601143257-10.png
- image-20220601143519-1.png
- image-20220601143642-2.png
- image-20220601143803-3.png
- image-20220601143921-4.png
Details
- Page properties
-
- Content
-
... ... @@ -35,7 +35,6 @@ 35 35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 36 36 37 37 38 - 39 39 == **1.2 Example 2: Connect to Pulse Counter** == 40 40 41 41 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -113,7 +113,7 @@ 113 113 114 114 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 115 115 116 -[[image:image-20220 527092629-8.png]]115 +[[image:image-20220601143257-10.png]] 117 117 118 118 119 119 (% class="box infomessage" %) ... ... @@ -161,7 +161,7 @@ 161 161 If the configured parameters and commands are incorrect, the return value is not obtained. 162 162 ))) 163 163 164 -[[image:image-20220 527092748-9.png]]163 +[[image:image-20220601143201-9.png]] 165 165 166 166 AT COMMAND 167 167 ... ... @@ -171,28 +171,30 @@ 171 171 AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 172 172 ))) 173 173 174 -a: length for the return of AT+COMMAND 173 +a: length for the return of AT+COMMAND 175 175 176 -b:1: grab valid value by byte, max 6 bytes .2: grab valid value by bytes section, max 3 sections.175 +b: 1: grab valid value by byte, max 6 bytes; 2: grab valid value by bytes section, max 3 sections. 177 177 178 -c: define the position for valid value. 177 +c: define the position for valid value. 179 179 180 -[[image:image-20220 527092936-10.png]]179 +[[image:image-20220601143115-8.png]] 181 181 182 182 AT COMMAND 183 183 184 184 184 + 185 185 PAYLOAD is available after the valid value is intercepted. 186 186 187 187 188 -[[image:image-20220 527093059-11.png]]188 +[[image:image-20220601143046-7.png]] 189 189 190 190 AT COMMAND 191 191 192 192 193 + 193 193 You can get configured PAYLOAD on TTN. 194 194 195 -[[image:image-20220 527093133-12.png]]196 +[[image:image-20220601143519-1.png]] 196 196 197 197 ((( 198 198 AT COMMAND ... ... @@ -248,7 +248,7 @@ 248 248 Payload:01 00 02 39 85 08 DC 00 00 00 44 249 249 ))) 250 250 251 -[[image:image-20220 527093204-13.png]]252 +[[image:image-20220601142936-6.png]] 252 252 253 253 AT COMMAND 254 254 ... ... @@ -255,8 +255,10 @@ 255 255 256 256 (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 257 257 258 -[[image:image-20220527093251-14.png]] 259 259 260 + 261 +[[image:image-20220601143642-2.png]] 262 + 260 260 AT COMMAND 261 261 262 262 ... ... @@ -320,6 +320,8 @@ 320 320 ))) 321 321 322 322 ((( 326 + 327 + 323 323 (% style="color:#4f81bd" %)**Example:** 324 324 ))) 325 325 ... ... @@ -332,23 +332,27 @@ 332 332 DOWNLINK 333 333 334 334 335 -[[image:image-20220527093508-17.png]] 336 336 341 +[[image:image-20220601143803-3.png]] 342 + 337 337 DOWNLINK 338 338 339 339 346 + 340 340 [[image:image-20220527093530-18.png]] 341 341 342 342 DOWNLINK 343 343 344 344 352 + 345 345 [[image:image-20220527093607-19.png]] 346 346 347 347 DOWNLINK 348 348 349 349 350 -[[image:image-20220527093628-20.png]] 351 351 359 +[[image:image-20220601142805-5.png]] 360 + 352 352 DOWNLINK 353 353 354 354 ... ... @@ -379,11 +379,13 @@ 379 379 USB 380 380 381 381 391 + 382 382 [[image:image-20220527093747-22.png]] 383 383 384 384 USB 385 385 386 386 397 + 387 387 ((( 388 388 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 389 389 ))) ... ... @@ -411,7 +411,7 @@ 411 411 ))) 412 412 ))) 413 413 414 -[[image:image-20220 527093849-24.png]]425 +[[image:image-20220601142044-1.png]] 415 415 416 416 417 417 **Example**:These two meters are examples of setting parameters and device addresses. ... ... @@ -438,7 +438,7 @@ 438 438 ))) 439 439 ))) 440 440 441 -[[image:image-20220 527094100-27.png]]452 +[[image:image-20220601142354-2.png]] 442 442 443 443 (% class="box infomessage" %) 444 444 ((( ... ... @@ -465,10 +465,10 @@ 465 465 466 466 Its default device address is 01, and the following are the parameters for configuring two energy meters. 467 467 468 -[[image:image-20220 527094150-28.png]]479 +[[image:image-20220601142452-3.png]] 469 469 470 470 471 -[[image:image-20220 527094224-29.png]]482 +[[image:image-20220601142607-4.png]] 472 472 473 473 **PAYLOAD:01 08 DF 43 62** 474 474 ... ... @@ -475,7 +475,6 @@ 475 475 * 08 DF is the valid value of the meter with device address 02. 476 476 * 43 62 is the valid value of the meter with device address 01. 477 477 478 - 479 479 == 1.4 Example 4: Circuit Breaker Remote Open Close == 480 480 481 481 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -486,7 +486,6 @@ 486 486 487 487 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 488 488 489 - 490 490 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 491 491 492 492 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -495,6 +495,7 @@ 495 495 496 496 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 497 497 507 + 498 498 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 499 499 500 500 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -501,6 +501,7 @@ 501 501 502 502 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 503 503 514 + 504 504 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 505 505 506 506 [[image:image-20220527094556-31.png]]
- image-20220601142044-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.7 KB - Content
- image-20220601142354-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.8 KB - Content
- image-20220601142452-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.1 KB - Content
- image-20220601142607-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.9 KB - Content
- image-20220601142805-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- image-20220601142936-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.7 KB - Content
- image-20220601143046-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.2 KB - Content
- image-20220601143115-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.9 KB - Content
- image-20220601143201-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content
- image-20220601143257-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- image-20220601143519-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- image-20220601143642-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.4 KB - Content
- image-20220601143803-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content
- image-20220601143921-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content