Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,12 +8,12 @@ 8 8 9 9 10 10 11 -= **1. Introduction**=11 += 1. Introduction = 12 12 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 -== **1.1 Example 1: Connect to Leak relay and VFD**==16 +== 1.1 Example 1: Connect to Leak relay and VFD == 17 17 18 18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 19 19 ... ... @@ -34,10 +34,8 @@ 34 34 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 35 35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 36 36 37 +== 1.2 Example 2: Connect to Pulse Counter == 37 37 38 - 39 -== **1.2 Example 2: Connect to Pulse Counter** == 40 - 41 41 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 42 42 43 43 [[image:image-20220527092058-3.png]] ... ... @@ -45,20 +45,18 @@ 45 45 Connection 46 46 47 47 48 - 49 49 [[image:image-20220527092146-4.png]] 50 50 51 51 Connection 52 52 53 - 54 54 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 55 55 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 56 56 57 57 == == 58 58 59 -== **1.3 Example3: Use RS485-LN with energy meters**==55 +== 1.3 Example3: Use RS485-LN with energy meters == 60 60 61 -=== **1.3.1 OverView**===57 +=== 1.3.1 OverView === 62 62 63 63 ((( 64 64 **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. ... ... @@ -73,7 +73,6 @@ 73 73 Connection1 74 74 75 75 76 - 77 77 ((( 78 78 How to connect with Energy Meter: 79 79 ))) ... ... @@ -108,7 +108,7 @@ 108 108 Connection3 109 109 110 110 111 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands**===106 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 112 112 113 113 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 114 114 ... ... @@ -475,6 +475,7 @@ 475 475 * 43 62 is the valid value of the meter with device address 01. 476 476 477 477 473 + 478 478 == 1.4 Example 4: Circuit Breaker Remote Open Close == 479 479 480 480 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -486,6 +486,7 @@ 486 486 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 487 487 488 488 485 + 489 489 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 490 490 491 491 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -494,6 +494,8 @@ 494 494 495 495 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 496 496 494 + 495 + 497 497 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 498 498 499 499 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -500,6 +500,8 @@ 500 500 501 501 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 502 502 502 + 503 + 503 503 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 504 504 505 505 [[image:image-20220527094556-31.png]]