<
From version < 41.12 >
edited by Xiaoling
on 2022/06/01 14:12
To version < 41.3 >
edited by Xiaoling
on 2022/05/30 11:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,12 +8,12 @@
8 8  
9 9  
10 10  
11 -= **1. Introduction** =
11 += 1. Introduction =
12 12  
13 13  This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
14 14  
15 15  
16 -== **1.1 Example 1: Connect to Leak relay and VFD** ==
16 +== 1.1 Example 1: Connect to Leak relay and VFD ==
17 17  
18 18  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
19 19  
... ... @@ -34,10 +34,8 @@
34 34  * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
35 35  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
36 36  
37 +== 1.2 Example 2: Connect to Pulse Counter ==
37 37  
38 -
39 -== **1.2 Example 2: Connect to Pulse Counter** ==
40 -
41 41  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
42 42  
43 43  [[image:image-20220527092058-3.png]]
... ... @@ -45,20 +45,18 @@
45 45  Connection
46 46  
47 47  
48 -
49 49  [[image:image-20220527092146-4.png]]
50 50  
51 51  Connection
52 52  
53 -
54 54  * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document
55 55  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
56 56  
57 57  == ==
58 58  
59 -== **1.3 Example3: Use RS485-LN with energy meters** ==
55 +== 1.3 Example3: Use RS485-LN with energy meters ==
60 60  
61 -=== **1.3.1 OverView** ===
57 +=== 1.3.1 OverView ===
62 62  
63 63  (((
64 64  **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.
... ... @@ -107,7 +107,7 @@
107 107  Connection3
108 108  
109 109  
110 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
106 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands ===
111 111  
112 112  If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter.
113 113  
... ... @@ -474,6 +474,7 @@
474 474  * 43 62 is the valid value of the meter with device address 01.
475 475  
476 476  
473 +
477 477  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
478 478  
479 479  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
... ... @@ -485,6 +485,7 @@
485 485  * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
486 486  
487 487  
485 +
488 488  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
489 489  
490 490  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
... ... @@ -493,6 +493,8 @@
493 493  
494 494  * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
495 495  
494 +
495 +
496 496  == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
497 497  
498 498  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0