... ... @@ -193,9 +193,7 @@
193 193  )))
194 194  
195 195  (((
196 -(% style="color:#4f81bd" %)**Example**:
197 -
198 -CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
196 +**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
199 199  )))
200 200  
201 201  (((
... ... @@ -204,8 +204,6 @@
204 204  
205 205  (((
206 206  AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload.
207 -
208 -
209 209  )))
210 210  
211 211  (((
... ... @@ -218,8 +218,6 @@
218 218  
219 219  (((
220 220  AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload.
221 -
222 -
223 223  )))
224 224  
225 225  (((
... ... @@ -263,7 +263,7 @@
263 263  )))
264 264  
265 265  (((
266 -(% style="color:#4f81bd" %)**Type Code 0xAF**
260 +**Type Code 0xAF**
267 267  )))
268 268  
269 269  (((
... ... @@ -310,11 +310,11 @@
310 310  )))
311 311  
312 312  (((
313 -(% style="color:#4f81bd" %)**Example:**
307 +Example:
314 314  )))
315 315  
316 316  (((
317 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
311 +AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1
318 318  )))
319 319  
320 320  [[image:image-20220527093430-16.png]]
... ... @@ -379,7 +379,7 @@
379 379  )))
380 380  
381 381  (((
382 -(% style="color:#4f81bd" %)**Example:**  (%%)input:01 03 00 31 00 02 95 c4
376 +**Example:**  input:01 03 00 31 00 02 95 c4
383 383  )))
384 384  
385 385  (((
... ... @@ -460,12 +460,11 @@
460 460  
461 461  [[image:image-20220527094224-29.png]]
462 462  
463 -**PAYLOAD:01 08 DF 43 62**
457 +PAYLOAD:01 08 DF 43 62
464 464  
465 465  * 08 DF is the valid value of the meter with device address 02.
466 466  * 43 62 is the valid value of the meter with device address 01.
467 467  
468 -
469 469  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
470 470  
471 471  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
... ... @@ -476,7 +476,6 @@
476 476  
477 477  * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
478 478  
479 -
480 480  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
481 481  
482 482  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
... ... @@ -485,7 +485,6 @@
485 485  
486 486  * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
487 487  
488 -
489 489  == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
490 490  
491 491  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
... ... @@ -492,7 +492,6 @@
492 492  
493 493  * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
494 494  
495 -
496 496  == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
497 497  
498 498  [[image:image-20220527094556-31.png]]