Summary

Details

Page properties
Content
... ... @@ -7,7 +7,6 @@
7 7  
8 8  This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
9 9  
10 -
11 11  == 1.1 Example 1: Connect to Leak relay and VFD ==
12 12  
13 13  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
... ... @@ -29,7 +29,6 @@
29 29  * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
30 30  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
31 31  
32 -
33 33  == 1.2 Example 2: Connect to Pulse Counter ==
34 34  
35 35  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
... ... @@ -193,9 +193,7 @@
193 193  )))
194 194  
195 195  (((
196 -(% style="color:#4f81bd" %)**Example**:
197 -
198 -CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
194 +**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
199 199  )))
200 200  
201 201  (((
... ... @@ -204,8 +204,6 @@
204 204  
205 205  (((
206 206  AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload.
207 -
208 -
209 209  )))
210 210  
211 211  (((
... ... @@ -218,8 +218,6 @@
218 218  
219 219  (((
220 220  AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload.
221 -
222 -
223 223  )))
224 224  
225 225  (((
... ... @@ -263,7 +263,7 @@
263 263  )))
264 264  
265 265  (((
266 -(% style="color:#4f81bd" %)**Type Code 0xAF**
258 +**Type Code 0xAF**
267 267  )))
268 268  
269 269  (((
... ... @@ -310,11 +310,11 @@
310 310  )))
311 311  
312 312  (((
313 -(% style="color:#4f81bd" %)**Example:**
305 +Example:
314 314  )))
315 315  
316 316  (((
317 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
309 +AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1
318 318  )))
319 319  
320 320  [[image:image-20220527093430-16.png]]
... ... @@ -379,7 +379,7 @@
379 379  )))
380 380  
381 381  (((
382 -(% style="color:#4f81bd" %)**Example:**  (%%)input:01 03 00 31 00 02 95 c4
374 +**Example:**  input:01 03 00 31 00 02 95 c4
383 383  )))
384 384  
385 385  (((
... ... @@ -428,12 +428,9 @@
428 428  )))
429 429  )))
430 430  
431 -[[image:image-20220527094100-27.png]]
423 +[[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]]
432 432  
433 -(% class="box infomessage" %)
434 -(((
435 -**AT+CFGDEV:01 10 00 61 00 01 02 00 02,1**
436 -)))
425 +AT+CFGDEV:01 10 00 61 00 01 02 00 02,1
437 437  
438 438  * 01:device adaress
439 439  
... ... @@ -455,28 +455,25 @@
455 455  
456 456  Its default device address is 01, and the following are the parameters for configuring two energy meters.
457 457  
458 -[[image:image-20220527094150-28.png]]
447 +[[image:https://wiki.dragino.com/images/1/13/Meter11.png||alt="Meter11.png" height="576" width="379"]]
459 459  
449 +[[image:https://wiki.dragino.com/images/thumb/7/7e/Meter12.png/600px-Meter12.png||alt="Meter12.png" height="262" width="600"]]
460 460  
461 -[[image:image-20220527094224-29.png]]
451 +PAYLOAD:01 08 DF 43 62
462 462  
463 -**PAYLOAD:01 08 DF 43 62**
464 -
465 465  * 08 DF is the valid value of the meter with device address 02.
466 466  * 43 62 is the valid value of the meter with device address 01.
467 467  
468 -
469 469  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
470 470  
471 471  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
472 472  
473 -[[image:image-20220527094330-30.png]]
460 +[[image:https://wiki.dragino.com/images/thumb/f/fa/RS485_04_2.png/600px-RS485_04_2.png||height="336" width="600"]]
474 474  
475 475  Connection
476 476  
477 477  * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
478 478  
479 -
480 480  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
481 481  
482 482  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
... ... @@ -485,7 +485,6 @@
485 485  
486 486  * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
487 487  
488 -
489 489  == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
490 490  
491 491  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
... ... @@ -492,10 +492,9 @@
492 492  
493 493  * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
494 494  
495 -
496 496  == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
497 497  
498 -[[image:image-20220527094556-31.png]]
482 +[[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]]
499 499  
500 500  Network Structure
501 501  
image-20220527094150-28.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -27.7 KB
Content
image-20220527094224-29.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -25.8 KB
Content
image-20220527094330-30.png
Author
... ... @@ -1,1 +1,0 @@