<
From version < 4.3 >
edited by Xiaoling
on 2022/05/12 10:44
To version < 1.14 >
edited by Xiaoling
on 2022/05/12 10:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,7 +10,6 @@
10 10  
11 11  Connection
12 12  
13 -
14 14  [[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %)
15 15  
16 16  Connection
... ... @@ -29,7 +29,6 @@
29 29  
30 30  Connection
31 31  
32 -
33 33  [[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]]
34 34  
35 35  Connection
... ... @@ -53,29 +53,17 @@
53 53  
54 54  Connection1
55 55  
56 -(((
57 57  How to connect with Energy Meter:
58 -)))
59 59  
60 -(((
61 61  Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively.
62 -)))
63 63  
64 -(((
65 65  The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
66 -)))
67 67  
68 -(((
69 69  Power Source VIN to RS485-LN VIN+
70 -)))
71 71  
72 -(((
73 73  Power Source GND to RS485-LN VIN-
74 -)))
75 75  
76 -(((
77 77  Once there is power, the RS485-LN will be on.
78 -)))
79 79  
80 80  [[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]]
81 81  
... ... @@ -82,7 +82,7 @@
82 82  Connection2
83 83  
84 84  
85 -[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="712" width="534"]]
71 +[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="763" width="573"]]
86 86  
87 87  Connection3
88 88  
... ... @@ -138,7 +138,7 @@
138 138  
139 139  (% class="box infomessage" %)
140 140  (((
141 - AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
127 +AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
142 142  )))
143 143  
144 144  a: length for the return of AT+COMMAND
... ... @@ -225,7 +225,7 @@
225 225  
226 226  ==== 1.3.3.2 via LoRaWAN DOWNLINK ====
227 227  
228 -[[image:image-20220512104358-3.png]]
214 +[[image:https://wiki.dragino.com/images/thumb/f/fc/DOWNLINK_METER1.png/600px-DOWNLINK_METER1.png||height="423" width="600"]]
229 229  
230 230  (((
231 231  DOWNLINK
... ... @@ -236,15 +236,12 @@
236 236  )))
237 237  
238 238  (((
239 -**Type Code 0xAF**
225 +Type Code 0xAF
240 240  )))
241 241  
242 242  (((
243 -(% class="box infomessage" %)
244 -(((
245 245  0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
246 246  )))
247 -)))
248 248  
249 249  (((
250 250  Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
... ... @@ -309,7 +309,6 @@
309 309  
310 310  DOWNLINK
311 311  
312 -
313 313  [[image:https://wiki.dragino.com/images/thumb/a/a2/DOWNLINK_METER6.png/600px-DOWNLINK_METER6.png||height="365" width="600"]]
314 314  
315 315  DOWNLINK
... ... @@ -337,12 +337,12 @@
337 337  check digit: Even
338 338  )))
339 339  
340 -[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="725" width="544"]]
322 +[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="800" width="600"]]
341 341  
342 342  USB
343 343  
344 344  
345 -[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="728" width="546"]]
327 +[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="800" width="600"]]
346 346  
347 347  USB
348 348  
... ... @@ -368,36 +368,28 @@
368 368  If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01.
369 369  
370 370  (((
371 -(((
372 372  Set the device address according to the parameters in the appendix of the MODBUS communication protocol.
373 373  )))
374 -)))
375 375  
376 376  [[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]]
377 377  
378 -**Example**:These two meters are examples of setting parameters and device addresses.
358 +Example:These two meters are examples of setting parameters and device addresses.
379 379  
380 -[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="737" width="553"]]
360 +[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="800" width="600"]]
381 381  
382 382  [[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]]
383 383  
384 384  (((
385 -(((
386 386  First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address.
387 387  )))
388 -)))
389 389  
390 390  (((
391 -(((
392 392  We can use AT+CFGDEV to set the device address.
393 393  )))
394 -)))
395 395  
396 396  (((
397 -(((
398 398  We modify the device address 01 of the first energy meter to 02.
399 399  )))
400 -)))
401 401  
402 402  [[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]]
403 403  
image-20220512104203-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -77.5 KB
Content
image-20220512104238-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -81.2 KB
Content
image-20220512104358-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -80.8 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0