Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -29,6 +29,7 @@ 29 29 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 30 30 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 31 31 32 + 32 32 == 1.2 Example 2: Connect to Pulse Counter == 33 33 34 34 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -192,7 +192,7 @@ 192 192 ))) 193 193 194 194 ((( 195 - (% style="color:#4f81bd" %)**Example**:196 +**Example**: 196 196 197 197 CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 198 198 ))) ... ... @@ -262,7 +262,7 @@ 262 262 ))) 263 263 264 264 ((( 265 - (% style="color:#4f81bd" %)**Type Code 0xAF**266 +**Type Code 0xAF** 266 266 ))) 267 267 268 268 ((( ... ... @@ -309,11 +309,11 @@ 309 309 ))) 310 310 311 311 ((( 312 - (% style="color:#4f81bd" %)**Example:**313 +Example: 313 313 ))) 314 314 315 315 ((( 316 - **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1317 +AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1 317 317 ))) 318 318 319 319 [[image:image-20220527093430-16.png]] ... ... @@ -378,7 +378,7 @@ 378 378 ))) 379 379 380 380 ((( 381 - (% style="color:#4f81bd" %)**Example:**(%%)input:01 03 00 31 00 02 95 c4382 +**Example:** input:01 03 00 31 00 02 95 c4 382 382 ))) 383 383 384 384 ((( ... ... @@ -459,12 +459,11 @@ 459 459 460 460 [[image:image-20220527094224-29.png]] 461 461 462 - **PAYLOAD:01 08 DF 43 62**463 +PAYLOAD:01 08 DF 43 62 463 463 464 464 * 08 DF is the valid value of the meter with device address 02. 465 465 * 43 62 is the valid value of the meter with device address 01. 466 466 467 - 468 468 == 1.4 Example 4: Circuit Breaker Remote Open Close == 469 469 470 470 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: