Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,7 +7,6 @@ 7 7 8 8 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 9 9 10 - 11 11 == 1.1 Example 1: Connect to Leak relay and VFD == 12 12 13 13 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: ... ... @@ -29,7 +29,6 @@ 29 29 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 30 30 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 31 31 32 - 33 33 == 1.2 Example 2: Connect to Pulse Counter == 34 34 35 35 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -193,9 +193,7 @@ 193 193 ))) 194 194 195 195 ((( 196 -**Example**: 197 - 198 -CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 194 +**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 199 199 ))) 200 200 201 201 ((( ... ... @@ -204,8 +204,6 @@ 204 204 205 205 ((( 206 206 AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 207 - 208 - 209 209 ))) 210 210 211 211 ((( ... ... @@ -218,8 +218,6 @@ 218 218 219 219 ((( 220 220 AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 221 - 222 - 223 223 ))) 224 224 225 225 ((( ... ... @@ -408,7 +408,7 @@ 408 408 409 409 [[image:image-20220527093950-25.png]] 410 410 411 -[[image:image -20220527094028-26.png]]403 +[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]] 412 412 413 413 ((( 414 414 ((( ... ... @@ -428,12 +428,9 @@ 428 428 ))) 429 429 ))) 430 430 431 -[[image:image -20220527094100-27.png]]423 +[[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]] 432 432 433 -(% class="box infomessage" %) 434 -((( 435 -**AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** 436 -))) 425 +AT+CFGDEV:01 10 00 61 00 01 02 00 02,1 437 437 438 438 * 01:device adaress 439 439 ... ... @@ -455,11 +455,10 @@ 455 455 456 456 Its default device address is 01, and the following are the parameters for configuring two energy meters. 457 457 458 -[[image:image -20220527094150-28.png]]447 +[[image:https://wiki.dragino.com/images/1/13/Meter11.png||alt="Meter11.png" height="576" width="379"]] 459 459 449 +[[image:https://wiki.dragino.com/images/thumb/7/7e/Meter12.png/600px-Meter12.png||alt="Meter12.png" height="262" width="600"]] 460 460 461 -[[image:image-20220527094224-29.png]] 462 - 463 463 PAYLOAD:01 08 DF 43 62 464 464 465 465 * 08 DF is the valid value of the meter with device address 02. ... ... @@ -469,7 +469,7 @@ 469 469 470 470 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: 471 471 472 -[[image:image -20220527094330-30.png]]460 +[[image:https://wiki.dragino.com/images/thumb/f/fa/RS485_04_2.png/600px-RS485_04_2.png||height="336" width="600"]] 473 473 474 474 Connection 475 475 ... ... @@ -491,7 +491,7 @@ 491 491 492 492 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 493 493 494 -[[image:image -20220527094556-31.png]]482 +[[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]] 495 495 496 496 Network Structure 497 497
- image-20220527094028-26.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -815.2 KB - Content
- image-20220527094100-27.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -2.3 KB - Content
- image-20220527094150-28.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.7 KB - Content
- image-20220527094224-29.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.8 KB - Content
- image-20220527094330-30.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -465.2 KB - Content
- image-20220527094556-31.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -162.5 KB - Content