29 29  * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
30 30  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
31 31  
32 -
33 33  == 1.2 Example 2: Connect to Pulse Counter ==
34 34  
35 35  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
... ... @@ -193,7 +193,9 @@
193 193  )))
194 194  
195 195  (((
196 -**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
195 +(% style="color:#4f81bd" %)**Example**:
196 +
197 +CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
197 197  )))
198 198  
199 199  (((
... ... @@ -202,6 +202,8 @@
202 202  
203 203  (((
204 204  AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload.
206 +
207 +
205 205  )))
206 206  
207 207  (((
... ... @@ -214,6 +214,8 @@
214 214  
215 215  (((
216 216  AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload.
220 +
221 +
217 217  )))
218 218  
219 219  (((
... ... @@ -257,7 +257,7 @@
257 257  )))
258 258  
259 259  (((
260 -**Type Code 0xAF**
265 +(% style="color:#4f81bd" %)**Type Code 0xAF**
261 261  )))
262 262  
263 263  (((
... ... @@ -304,11 +304,11 @@
304 304  )))
305 305  
306 306  (((
307 -Example:
312 +(% style="color:#4f81bd" %)**Example:**
308 308  )))
309 309  
310 310  (((
311 -AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1
316 +**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
312 312  )))
313 313  
314 314  [[image:image-20220527093430-16.png]]
... ... @@ -373,7 +373,7 @@
373 373  )))
374 374  
375 375  (((
376 -**Example:**  input:01 03 00 31 00 02 95 c4
381 +(% style="color:#4f81bd" %)**Example:**  (%%)input:01 03 00 31 00 02 95 c4
377 377  )))
378 378  
379 379  (((
... ... @@ -454,11 +454,12 @@
454 454  
455 455  [[image:image-20220527094224-29.png]]
456 456  
457 -PAYLOAD:01 08 DF 43 62
462 +**PAYLOAD:01 08 DF 43 62**
458 458  
459 459  * 08 DF is the valid value of the meter with device address 02.
460 460  * 43 62 is the valid value of the meter with device address 01.
461 461  
467 +
462 462  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
463 463  
464 464  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
... ... @@ -469,6 +469,7 @@
469 469  
470 470  * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
471 471  
478 +
472 472  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
473 473  
474 474  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
... ... @@ -477,6 +477,7 @@
477 477  
478 478  * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
479 479  
487 +
480 480  == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
481 481  
482 482  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
... ... @@ -483,6 +483,7 @@
483 483  
484 484  * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
485 485  
494 +
486 486  == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
487 487  
488 488  [[image:image-20220527094556-31.png]]