Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,7 +7,6 @@ 7 7 8 8 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 9 9 10 - 11 11 == 1.1 Example 1: Connect to Leak relay and VFD == 12 12 13 13 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: ... ... @@ -29,7 +29,6 @@ 29 29 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 30 30 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 31 31 32 - 33 33 == 1.2 Example 2: Connect to Pulse Counter == 34 34 35 35 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -459,6 +459,7 @@ 459 459 * 08 DF is the valid value of the meter with device address 02. 460 460 * 43 62 is the valid value of the meter with device address 01. 461 461 460 + 462 462 == 1.4 Example 4: Circuit Breaker Remote Open Close == 463 463 464 464 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -469,6 +469,7 @@ 469 469 470 470 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 471 471 471 + 472 472 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 473 473 474 474 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -485,7 +485,7 @@ 485 485 486 486 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 487 487 488 -[[image:image -20220527094556-31.png]]488 +[[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]] 489 489 490 490 Network Structure 491 491