<
From version < 39.1 >
edited by Xiaoling
on 2022/05/27 09:47
To version < 39.6 >
edited by Xiaoling
on 2022/05/27 09:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -192,7 +192,9 @@
192 192  )))
193 193  
194 194  (((
195 -**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
195 +(% style="color:#4f81bd" %)**Example**:
196 +
197 +CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
196 196  )))
197 197  
198 198  (((
... ... @@ -201,6 +201,8 @@
201 201  
202 202  (((
203 203  AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload.
206 +
207 +
204 204  )))
205 205  
206 206  (((
... ... @@ -213,6 +213,8 @@
213 213  
214 214  (((
215 215  AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload.
220 +
221 +
216 216  )))
217 217  
218 218  (((
... ... @@ -256,7 +256,7 @@
256 256  )))
257 257  
258 258  (((
259 -**Type Code 0xAF**
265 +(% style="color:#4f81bd" %)**Type Code 0xAF**
260 260  )))
261 261  
262 262  (((
... ... @@ -303,11 +303,11 @@
303 303  )))
304 304  
305 305  (((
306 -Example:
312 +(% style="color:#4f81bd" %)**Example:**
307 307  )))
308 308  
309 309  (((
310 -AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1
316 +**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
311 311  )))
312 312  
313 313  [[image:image-20220527093430-16.png]]
... ... @@ -372,7 +372,7 @@
372 372  )))
373 373  
374 374  (((
375 -**Example:**  input:01 03 00 31 00 02 95 c4
381 +(% style="color:#4f81bd" %)**Example:**  (%%)input:01 03 00 31 00 02 95 c4
376 376  )))
377 377  
378 378  (((
... ... @@ -453,11 +453,12 @@
453 453  
454 454  [[image:image-20220527094224-29.png]]
455 455  
456 -PAYLOAD:01 08 DF 43 62
462 +**PAYLOAD:01 08 DF 43 62**
457 457  
458 458  * 08 DF is the valid value of the meter with device address 02.
459 459  * 43 62 is the valid value of the meter with device address 01.
460 460  
467 +
461 461  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
462 462  
463 463  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
... ... @@ -468,6 +468,7 @@
468 468  
469 469  * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
470 470  
478 +
471 471  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
472 472  
473 473  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
... ... @@ -476,6 +476,7 @@
476 476  
477 477  * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
478 478  
487 +
479 479  == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
480 480  
481 481  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0