... ... @@ -192,7 +192,9 @@
192 192  )))
193 193  
194 194  (((
195 -**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
195 +(% style="color:#4f81bd" %)**Example**:
196 +
197 +CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
196 196  )))
197 197  
198 198  (((
... ... @@ -201,6 +201,8 @@
201 201  
202 202  (((
203 203  AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload.
206 +
207 +
204 204  )))
205 205  
206 206  (((
... ... @@ -213,6 +213,8 @@
213 213  
214 214  (((
215 215  AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload.
220 +
221 +
216 216  )))
217 217  
218 218  (((
... ... @@ -256,7 +256,7 @@
256 256  )))
257 257  
258 258  (((
259 -**Type Code 0xAF**
265 +(% style="color:#4f81bd" %)**Type Code 0xAF**
260 260  )))
261 261  
262 262  (((
... ... @@ -303,11 +303,11 @@
303 303  )))
304 304  
305 305  (((
306 -Example:
312 +(% style="color:#4f81bd" %)**Example:**
307 307  )))
308 308  
309 309  (((
310 -AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1
316 +**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
311 311  )))
312 312  
313 313  [[image:image-20220527093430-16.png]]
... ... @@ -372,7 +372,7 @@
372 372  )))
373 373  
374 374  (((
375 -**Example:**  input:01 03 00 31 00 02 95 c4
381 +(% style="color:#4f81bd" %)**Example:**  (%%)input:01 03 00 31 00 02 95 c4
376 376  )))
377 377  
378 378  (((
... ... @@ -453,11 +453,12 @@
453 453  
454 454  [[image:image-20220527094224-29.png]]
455 455  
456 -PAYLOAD:01 08 DF 43 62
462 +**PAYLOAD:01 08 DF 43 62**
457 457  
458 458  * 08 DF is the valid value of the meter with device address 02.
459 459  * 43 62 is the valid value of the meter with device address 01.
460 460  
467 +
461 461  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
462 462  
463 463  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: