Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -192,7 +192,9 @@ 192 192 ))) 193 193 194 194 ((( 195 -**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 195 +(% style="color:#4f81bd" %)**Example**: 196 + 197 +CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 196 196 ))) 197 197 198 198 ((( ... ... @@ -201,6 +201,8 @@ 201 201 202 202 ((( 203 203 AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 206 + 207 + 204 204 ))) 205 205 206 206 ((( ... ... @@ -213,6 +213,8 @@ 213 213 214 214 ((( 215 215 AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 220 + 221 + 216 216 ))) 217 217 218 218 ((( ... ... @@ -256,7 +256,7 @@ 256 256 ))) 257 257 258 258 ((( 259 -**Type Code 0xAF** 265 +(% style="color:#4f81bd" %)**Type Code 0xAF** 260 260 ))) 261 261 262 262 ((( ... ... @@ -303,11 +303,11 @@ 303 303 ))) 304 304 305 305 ((( 306 -Example: 312 +(% style="color:#4f81bd" %)**Example:** 307 307 ))) 308 308 309 309 ((( 310 -AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1 316 +**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 311 311 ))) 312 312 313 313 [[image:image-20220527093430-16.png]] ... ... @@ -372,7 +372,7 @@ 372 372 ))) 373 373 374 374 ((( 375 -**Example:** input:01 03 00 31 00 02 95 c4 381 +(% style="color:#4f81bd" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4 376 376 ))) 377 377 378 378 ((( ... ... @@ -453,11 +453,12 @@ 453 453 454 454 [[image:image-20220527094224-29.png]] 455 455 456 -PAYLOAD:01 08 DF 43 62 462 +**PAYLOAD:01 08 DF 43 62** 457 457 458 458 * 08 DF is the valid value of the meter with device address 02. 459 459 * 43 62 is the valid value of the meter with device address 01. 460 460 467 + 461 461 == 1.4 Example 4: Circuit Breaker Remote Open Close == 462 462 463 463 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: