Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 35 removed)
- image-20220512104203-1.png
- image-20220512104238-2.png
- image-20220512104358-3.png
- image-20220512115601-1.png
- image-20220527091852-1.png
- image-20220527091942-2.png
- image-20220527092058-3.png
- image-20220527092146-4.png
- image-20220527092419-5.png
- image-20220527092514-6.png
- image-20220527092555-7.png
- image-20220527092629-8.png
- image-20220527092748-9.png
- image-20220527092936-10.png
- image-20220527093059-11.png
- image-20220527093133-12.png
- image-20220527093204-13.png
- image-20220527093251-14.png
- image-20220527093358-15.png
- image-20220527093430-16.png
- image-20220527093508-17.png
- image-20220527093530-18.png
- image-20220527093607-19.png
- image-20220527093628-20.png
- image-20220527093708-21.png
- image-20220527093747-22.png
- image-20220527093821-23.png
- image-20220527093849-24.png
- image-20220527093950-25.png
- image-20220527094028-26.png
- image-20220527094100-27.png
- image-20220527094150-28.png
- image-20220527094224-29.png
- image-20220527094330-30.png
- image-20220527094556-31.png
Details
- Page properties
-
- Content
-
... ... @@ -1,28 +6,19 @@ 1 -(% class="wikigeneratedid" %) 2 - **Contents:** 3 - 4 -{{toc/}} 5 - 6 6 = 1. Introduction = 7 7 8 8 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 9 9 10 - 11 11 == 1.1 Example 1: Connect to Leak relay and VFD == 12 12 13 13 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 14 14 15 -[[image:image -20220527091852-1.png]]9 +[[image:https://wiki.dragino.com/images/thumb/5/5c/RS485_01.png/600px-RS485_01.png||height="297" width="534"]] 16 16 17 17 Connection 18 18 13 +[[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %) 19 19 20 - 21 -[[image:image-20220527091942-2.png]](% style="display:none" %) 22 - 23 23 Connection 24 24 25 - 26 26 Related documents: 27 27 28 28 * [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure ... ... @@ -33,20 +33,17 @@ 33 33 34 34 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 35 35 36 -[[image:image -20220527092058-3.png]]27 +[[image:https://wiki.dragino.com/images/thumb/3/34/RS485_02_1.png/600px-RS485_02_1.png||height="364" width="600"]] 37 37 38 38 Connection 39 39 31 +[[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]] 40 40 41 -[[image:image-20220527092146-4.png]] 42 - 43 43 Connection 44 44 45 45 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 46 46 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 47 47 48 -== == 49 - 50 50 == 1.3 Example3: Use RS485-LN with energy meters == 51 51 52 52 === 1.3.1 OverView === ... ... @@ -59,41 +59,28 @@ 59 59 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 60 60 ))) 61 61 62 -[[image:image -20220527092419-5.png]]50 +[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height="726" width="545"]] 63 63 64 64 Connection1 65 65 66 - 67 -((( 68 68 How to connect with Energy Meter: 69 -))) 70 70 71 -((( 72 72 Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively. 73 -))) 74 74 75 -((( 76 76 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 77 -))) 78 78 79 -((( 80 80 Power Source VIN to RS485-LN VIN+ 81 -))) 82 82 83 -((( 84 84 Power Source GND to RS485-LN VIN- 85 -))) 86 86 87 -((( 88 88 Once there is power, the RS485-LN will be on. 89 -))) 90 90 91 -[[image:image -20220527092514-6.png]]66 +[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]] 92 92 93 93 Connection2 94 94 95 95 96 -[[image:image -20220527092555-7.png]]71 +[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="763" width="573"]] 97 97 98 98 Connection3 99 99 ... ... @@ -102,12 +102,11 @@ 102 102 103 103 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 104 104 105 -[[image:image -20220527092629-8.png]]80 +[[image:https://wiki.dragino.com/images/thumb/3/35/Meter4.png/600px-Meter4.png||alt="Meter4.png" height="193" width="600"]] 106 106 107 - 108 108 (% class="box infomessage" %) 109 109 ((( 110 - **Example:**AT+COMMAND1=01 03 00 00 00 01 84 0A84 +Example:AT+COMMAND1=01 03 00 00 00 01 84 0A 111 111 ))) 112 112 113 113 * The first byte : slave address code (=001~247) ... ... @@ -122,7 +122,7 @@ 122 122 123 123 (% class="box infomessage" %) 124 124 ((( 125 - **Example:**RETURN1:01 03 02 08 FD 7E 0599 +Example:RETURN1:01 03 02 08 FD 7E 05 126 126 ))) 127 127 128 128 * The first byte ARD: slave address code (=001~254) ... ... @@ -132,16 +132,10 @@ 132 132 * The 6th and 7th bytes: CRC16 checksum 133 133 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 134 134 135 -(% class="wikigeneratedid" %) 136 -((( 137 - 138 -))) 139 - 140 140 === 1.3.3 How to configure RS485-LN and parse output commands === 141 141 142 142 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 143 143 144 - 145 145 ==== 1.3.3.1 via AT COMMAND: ==== 146 146 147 147 First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct. ... ... @@ -150,14 +150,13 @@ 150 150 If the configured parameters and commands are incorrect, the return value is not obtained. 151 151 ))) 152 152 153 -[[image:image -20220527092748-9.png]]121 +[[image:https://wiki.dragino.com/images/b/bc/AT_COMMAND1.png||height="358" width="456"]] 154 154 155 155 AT COMMAND 156 156 157 - 158 158 (% class="box infomessage" %) 159 159 ((( 160 - 127 +AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 161 161 ))) 162 162 163 163 a: length for the return of AT+COMMAND ... ... @@ -166,32 +166,27 @@ 166 166 167 167 c: define the position for valid value. 168 168 169 -[[image:image -20220527092936-10.png]]136 +[[image:https://wiki.dragino.com/images/7/7d/AT_COMMAND2.png||height="278" width="477"]] 170 170 171 171 AT COMMAND 172 172 173 - 174 174 PAYLOAD is available after the valid value is intercepted. 175 175 176 176 177 -[[image:image -20220527093059-11.png]]143 +[[image:https://wiki.dragino.com/images/3/3a/AT_COMMAND4.png||height="219" width="576"]] 178 178 179 179 AT COMMAND 180 180 181 - 182 182 You can get configured PAYLOAD on TTN. 183 183 184 -[[image:image-20220527093133-12.png]] 185 185 150 +[[image:https://wiki.dragino.com/images/thumb/c/c2/AT_COMMAND3.png/600px-AT_COMMAND3.png||height="138" width="600"]] 151 + 186 186 ((( 187 187 AT COMMAND 188 188 ))) 189 189 190 190 ((( 191 - 192 -))) 193 - 194 -((( 195 195 **Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 196 196 ))) 197 197 ... ... @@ -231,14 +231,14 @@ 231 231 Payload:01 00 02 39 85 08 DC 00 00 00 44 232 232 ))) 233 233 234 -[[image:image -20220527093204-13.png]]196 +[[image:https://wiki.dragino.com/images/thumb/9/9b/AT_COMMAND10.png/600px-AT_COMMAND10.png||height="278" width="600"]] 235 235 236 236 AT COMMAND 237 237 200 +01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy. 238 238 239 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 240 240 241 -[[image:image -20220527093251-14.png]]203 +[[~[~[image:https://wiki.dragino.com/images/thumb/b/b8/AT_COMMAND11.png/600px-AT_COMMAND11.png~|~|height="271" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:AT_COMMAND11.png]] 242 242 243 243 AT COMMAND 244 244 ... ... @@ -245,7 +245,7 @@ 245 245 246 246 ==== 1.3.3.2 via LoRaWAN DOWNLINK ==== 247 247 248 -[[image:image -20220527093358-15.png]]210 +[[image:https://wiki.dragino.com/images/thumb/f/fc/DOWNLINK_METER1.png/600px-DOWNLINK_METER1.png||height="423" width="600"]] 249 249 250 250 ((( 251 251 DOWNLINK ... ... @@ -256,15 +256,12 @@ 256 256 ))) 257 257 258 258 ((( 259 - **Type Code 0xAF**221 +Type Code 0xAF 260 260 ))) 261 261 262 262 ((( 263 -(% class="box infomessage" %) 264 -((( 265 265 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 266 266 ))) 267 -))) 268 268 269 269 ((( 270 270 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. ... ... @@ -310,123 +310,84 @@ 310 310 AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1 311 311 ))) 312 312 313 -[[image:image -20220527093430-16.png]]272 +[[image:https://wiki.dragino.com/images/thumb/4/45/DOWNLINK_METER2.png/600px-DOWNLINK_METER2.png||height="208" width="600"]] 314 314 315 315 DOWNLINK 316 316 317 317 318 -[[image:image -20220527093508-17.png]]277 +[[~[~[image:https://wiki.dragino.com/images/thumb/2/20/DOWNLINK_METER3.png/600px-DOWNLINK_METER3.png~|~|height="105" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER3.png]] 319 319 320 320 DOWNLINK 321 321 322 322 323 -[[image:image -20220527093530-18.png]]282 +[[image:https://wiki.dragino.com/images/thumb/2/27/DOWNLINK_METER4.png/600px-DOWNLINK_METER4.png||height="210" width="600"]] 324 324 325 325 DOWNLINK 326 326 327 327 328 -[[image:image -20220527093607-19.png]]287 +[[~[~[image:https://wiki.dragino.com/images/thumb/3/39/DOWNLINK_METER5.png/600px-DOWNLINK_METER5.png~|~|height="176" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER5.png]] 329 329 330 330 DOWNLINK 331 331 291 +[[image:https://wiki.dragino.com/images/thumb/a/a2/DOWNLINK_METER6.png/600px-DOWNLINK_METER6.png||height="365" width="600"]] 332 332 333 -[[image:image-20220527093628-20.png]] 334 - 335 335 DOWNLINK 336 336 337 337 338 338 === 1.3.4 How to configure and output commands for RS485 to USB === 339 339 340 -((( 341 341 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN. 342 -))) 343 343 344 -((( 345 345 First, connect the A+ and A- of the USB to the 485 A and 485 B of the energy meter. 346 -))) 347 347 348 -((( 349 349 Open the serial port debugging, set the send and receive to HEX. 350 -))) 351 351 352 -((( 353 353 Baud rate: 9600 354 -))) 355 355 356 -((( 357 357 check digit: Even 358 -))) 359 359 360 -[[image:image -20220527093708-21.png]]308 +[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="800" width="600"]] 361 361 362 362 USB 363 363 312 +[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="800" width="600"]] 364 364 365 -[[image:image-20220527093747-22.png]] 366 - 367 367 USB 368 368 369 - 370 -((( 371 371 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 372 -))) 373 373 374 -((( 375 -**Example:** input:01 03 00 31 00 02 95 c4 376 -))) 318 +Example:input:01 03 00 31 00 02 95 c4 377 377 378 -((( 379 - output:01 03 04 00 00 00 42 7A 02 380 -))) 320 +{{{ output:01 03 04 00 00 00 42 7A 02 321 +}}} 381 381 382 -[[image:image -20220527093821-23.png]]323 +[[image:https://wiki.dragino.com/images/thumb/b/b3/Usb_meter3.jpg/600px-Usb_meter3.jpg||height="466" width="600"]] 383 383 384 384 USB 385 385 386 - 387 387 === 1.3.5 How to configure multiple devices and modify device addresses === 388 388 389 389 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 390 390 391 -((( 392 -((( 393 393 Set the device address according to the parameters in the appendix of the MODBUS communication protocol. 394 -))) 395 -))) 396 396 397 -[[image:image -20220527093849-24.png]]333 +[[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]] 398 398 335 +Example:These two meters are examples of setting parameters and device addresses. 399 399 400 - **Example**:Thesetwors arexamples of settingparametersand deviceaddresses.337 +[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="800" width="600"]] 401 401 402 -[[image:image -20220527093950-25.png]]339 +[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="800" width="600"]] 403 403 404 -[[image:image-20220527094028-26.png]] 405 - 406 -((( 407 -((( 408 408 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. 409 -))) 410 -))) 411 411 412 -((( 413 -((( 414 414 We can use AT+CFGDEV to set the device address. 415 -))) 416 -))) 417 417 418 -((( 419 -((( 420 420 We modify the device address 01 of the first energy meter to 02. 421 -))) 422 -))) 423 423 424 -[[image:image -20220527094100-27.png]]347 +[[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]] 425 425 426 -(% class="box infomessage" %) 427 -((( 428 -**AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** 429 -))) 349 +AT+CFGDEV:01 10 00 61 00 01 02 00 02,1 430 430 431 431 * 01:device adaress 432 432 ... ... @@ -448,11 +448,10 @@ 448 448 449 449 Its default device address is 01, and the following are the parameters for configuring two energy meters. 450 450 451 -[[image:image -20220527094150-28.png]]371 +[[image:https://wiki.dragino.com/images/1/13/Meter11.png||alt="Meter11.png" height="576" width="379"]] 452 452 373 +[[image:https://wiki.dragino.com/images/thumb/7/7e/Meter12.png/600px-Meter12.png||alt="Meter12.png" height="262" width="600"]] 453 453 454 -[[image:image-20220527094224-29.png]] 455 - 456 456 PAYLOAD:01 08 DF 43 62 457 457 458 458 * 08 DF is the valid value of the meter with device address 02. ... ... @@ -462,7 +462,7 @@ 462 462 463 463 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: 464 464 465 -[[image:image -20220527094330-30.png]]384 +[[image:https://wiki.dragino.com/images/thumb/f/fa/RS485_04_2.png/600px-RS485_04_2.png||height="336" width="600"]] 466 466 467 467 Connection 468 468 ... ... @@ -484,7 +484,7 @@ 484 484 485 485 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 486 486 487 -[[image:image -20220527094556-31.png]]406 +[[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]] 488 488 489 489 Network Structure 490 490
- image-20220512104203-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -77.5 KB - Content
- image-20220512104238-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -81.2 KB - Content
- image-20220512104358-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -80.8 KB - Content
- image-20220512115601-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.4 KB - Content
- image-20220527091852-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -542.6 KB - Content
- image-20220527091942-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -608.5 KB - Content
- image-20220527092058-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -740.9 KB - Content
- image-20220527092146-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -686.5 KB - Content
- image-20220527092419-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -519.8 KB - Content
- image-20220527092514-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -819.1 KB - Content
- image-20220527092555-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -537.6 KB - Content
- image-20220527092629-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -9.1 KB - Content
- image-20220527092748-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.3 KB - Content
- image-20220527092936-10.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -11.3 KB - Content
- image-20220527093059-11.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -10.9 KB - Content
- image-20220527093133-12.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -12.1 KB - Content
- image-20220527093204-13.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.5 KB - Content
- image-20220527093251-14.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -39.3 KB - Content
- image-20220527093358-15.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -62.9 KB - Content
- image-20220527093430-16.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.9 KB - Content
- image-20220527093508-17.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.5 KB - Content
- image-20220527093530-18.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.5 KB - Content
- image-20220527093607-19.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.3 KB - Content
- image-20220527093628-20.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.6 KB - Content
- image-20220527093708-21.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -569.4 KB - Content
- image-20220527093747-22.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -672.8 KB - Content
- image-20220527093821-23.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -161.5 KB - Content
- image-20220527093849-24.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.4 KB - Content
- image-20220527093950-25.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -624.4 KB - Content
- image-20220527094028-26.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -815.2 KB - Content
- image-20220527094100-27.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -2.3 KB - Content
- image-20220527094150-28.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.7 KB - Content
- image-20220527094224-29.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.8 KB - Content
- image-20220527094330-30.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -465.2 KB - Content
- image-20220527094556-31.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -162.5 KB - Content