Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -398,9 +398,9 @@ 398 398 399 399 **Example**:These two meters are examples of setting parameters and device addresses. 400 400 401 -[[image: https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="737" width="553"]]401 +[[image:image-20220527093950-25.png]] 402 402 403 -[[image: https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]]403 +[[image:image-20220527094028-26.png]] 404 404 405 405 ((( 406 406 ((( ... ... @@ -420,9 +420,12 @@ 420 420 ))) 421 421 ))) 422 422 423 -[[image: https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]]423 +[[image:image-20220527094100-27.png]] 424 424 425 -AT+CFGDEV:01 10 00 61 00 01 02 00 02,1 425 +(% class="box infomessage" %) 426 +((( 427 +**AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** 428 +))) 426 426 427 427 * 01:device adaress 428 428 ... ... @@ -444,15 +444,17 @@ 444 444 445 445 Its default device address is 01, and the following are the parameters for configuring two energy meters. 446 446 447 -[[image: https://wiki.dragino.com/images/1/13/Meter11.png||alt="Meter11.png" height="576" width="379"]]450 +[[image:image-20220527094150-28.png]] 448 448 449 -[[image:https://wiki.dragino.com/images/thumb/7/7e/Meter12.png/600px-Meter12.png||alt="Meter12.png" height="262" width="600"]] 450 450 453 +[[image:image-20220527094224-29.png]] 454 + 451 451 PAYLOAD:01 08 DF 43 62 452 452 453 453 * 08 DF is the valid value of the meter with device address 02. 454 454 * 43 62 is the valid value of the meter with device address 01. 455 455 460 + 456 456 == 1.4 Example 4: Circuit Breaker Remote Open Close == 457 457 458 458 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
- image-20220527093950-25.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +624.4 KB - Content
- image-20220527094028-26.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +815.2 KB - Content
- image-20220527094100-27.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.3 KB - Content
- image-20220527094150-28.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.7 KB - Content
- image-20220527094224-29.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.8 KB - Content