From version < 23.1 >
edited by Xiaoling
on 2022/05/27 09:35
To version < 21.1 >
edited by Xiaoling
on 2022/05/27 09:33
>
Change comment: Uploaded new attachment "image-20220527093358-15.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -28,6 +28,7 @@
28 28  * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
29 29  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
30 30  
31 +
31 31  == 1.2 Example 2: Connect to Pulse Counter ==
32 32  
33 33  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
... ... @@ -44,6 +44,7 @@
44 44  * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document
45 45  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
46 46  
48 +(% class="wikigeneratedid" %)
47 47  == ==
48 48  
49 49  == 1.3 Example3: Use RS485-LN with energy meters ==
... ... @@ -235,7 +235,7 @@
235 235  AT COMMAND
236 236  
237 237  
238 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
240 +01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.
239 239  
240 240  [[image:image-20220527093251-14.png]]
241 241  
... ... @@ -244,7 +244,7 @@
244 244  
245 245  ==== 1.3.3.2 via LoRaWAN DOWNLINK ====
246 246  
247 -[[image:image-20220527093358-15.png]]
249 +[[image:image-20220512104358-3.png]]
248 248  
249 249  (((
250 250  DOWNLINK
... ... @@ -309,7 +309,7 @@
309 309  AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1
310 310  )))
311 311  
312 -[[image:image-20220527093430-16.png]]
314 +[[image:https://wiki.dragino.com/images/thumb/4/45/DOWNLINK_METER2.png/600px-DOWNLINK_METER2.png||height="208" width="600"]]
313 313  
314 314  DOWNLINK
315 315  
image-20220527093430-16.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -16.9 KB
Content
image-20220527093508-17.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -21.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0