<
From version < 20.2 >
edited by Xiaoling
on 2022/05/27 09:32
To version < 23.1 >
edited by Xiaoling
on 2022/05/27 09:35
>
Change comment: Uploaded new attachment "image-20220527093508-17.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -28,7 +28,6 @@
28 28  * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
29 29  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
30 30  
31 -
32 32  == 1.2 Example 2: Connect to Pulse Counter ==
33 33  
34 34  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
... ... @@ -45,7 +45,6 @@
45 45  * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document
46 46  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
47 47  
48 -(% class="wikigeneratedid" %)
49 49  == ==
50 50  
51 51  == 1.3 Example3: Use RS485-LN with energy meters ==
... ... @@ -237,7 +237,7 @@
237 237  AT COMMAND
238 238  
239 239  
240 -01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.
238 +(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
241 241  
242 242  [[image:image-20220527093251-14.png]]
243 243  
... ... @@ -246,7 +246,7 @@
246 246  
247 247  ==== 1.3.3.2 via LoRaWAN DOWNLINK ====
248 248  
249 -[[image:image-20220512104358-3.png]]
247 +[[image:image-20220527093358-15.png]]
250 250  
251 251  (((
252 252  DOWNLINK
... ... @@ -311,7 +311,7 @@
311 311  AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1
312 312  )))
313 313  
314 -[[image:https://wiki.dragino.com/images/thumb/4/45/DOWNLINK_METER2.png/600px-DOWNLINK_METER2.png||height="208" width="600"]]
312 +[[image:image-20220527093430-16.png]]
315 315  
316 316  DOWNLINK
317 317  
image-20220527093358-15.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +62.9 KB
Content
image-20220527093430-16.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +16.9 KB
Content
image-20220527093508-17.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +21.5 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0