Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 14 removed)
- image-20220512104203-1.png
- image-20220512104238-2.png
- image-20220512104358-3.png
- image-20220512115601-1.png
- image-20220527091852-1.png
- image-20220527091942-2.png
- image-20220527092058-3.png
- image-20220527092146-4.png
- image-20220527092419-5.png
- image-20220527092514-6.png
- image-20220527092555-7.png
- image-20220527092629-8.png
- image-20220527092748-9.png
- image-20220527092936-10.png
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +6,3 @@ 1 -(% class="wikigeneratedid" %) 2 - **Contents:** 3 - 4 -{{toc/}} 5 - 6 6 = 1. Introduction = 7 7 8 8 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. ... ... @@ -11,17 +11,14 @@ 11 11 12 12 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 13 13 14 -[[image:image -20220527091852-1.png]]9 +[[image:https://wiki.dragino.com/images/thumb/5/5c/RS485_01.png/600px-RS485_01.png||height="297" width="534"]] 15 15 16 16 Connection 17 17 13 +[[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %) 18 18 19 - 20 -[[image:image-20220527091942-2.png]](% style="display:none" %) 21 - 22 22 Connection 23 23 24 - 25 25 Related documents: 26 26 27 27 * [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure ... ... @@ -33,20 +33,17 @@ 33 33 34 34 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 35 35 36 -[[image:image -20220527092058-3.png]]28 +[[image:https://wiki.dragino.com/images/thumb/3/34/RS485_02_1.png/600px-RS485_02_1.png||height="364" width="600"]] 37 37 38 38 Connection 39 39 32 +[[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]] 40 40 41 -[[image:image-20220527092146-4.png]] 42 - 43 43 Connection 44 44 45 45 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 46 46 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 47 47 48 -(% class="wikigeneratedid" %) 49 -== == 50 50 51 51 == 1.3 Example3: Use RS485-LN with energy meters == 52 52 ... ... @@ -53,7 +53,7 @@ 53 53 === 1.3.1 OverView === 54 54 55 55 ((( 56 - **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.45 +Note:The specifications of each energy meter are different, please refer to your own energy meter specifications. 57 57 ))) 58 58 59 59 ((( ... ... @@ -60,54 +60,40 @@ 60 60 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 61 61 ))) 62 62 63 -[[image:image -20220527092419-5.png]]52 +[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height="800" width="600"]] 64 64 65 65 Connection1 66 66 67 - 68 -((( 69 69 How to connect with Energy Meter: 70 -))) 71 71 72 -((( 73 73 Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively. 74 -))) 75 75 76 -((( 77 77 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 78 -))) 79 79 80 -((( 81 81 Power Source VIN to RS485-LN VIN+ 82 -))) 83 83 84 -((( 85 85 Power Source GND to RS485-LN VIN- 86 -))) 87 87 88 -((( 89 89 Once there is power, the RS485-LN will be on. 90 -))) 91 91 92 -[[image:image -20220527092514-6.png]]68 +[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="450" width="600"]] 93 93 94 94 Connection2 95 95 72 +[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="800" width="600"]] 96 96 97 - 98 98 Connection3 99 99 100 100 101 101 === 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 102 102 103 -If the user needs to read the parameters of the electric energy meter and use the modbus command, please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter.79 +If the user needs to read the parameters of the electric energy meter and use the modbus command, 104 104 81 +please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 82 + 105 105 [[image:https://wiki.dragino.com/images/thumb/3/35/Meter4.png/600px-Meter4.png||alt="Meter4.png" height="193" width="600"]] 106 106 107 -(% class="box infomessage" %) 108 -((( 109 109 Example:AT+COMMAND1=01 03 00 00 00 01 84 0A 110 -))) 111 111 112 112 * The first byte : slave address code (=001~247) 113 113 * The second byte : read register value function code ... ... @@ -115,14 +115,9 @@ 115 115 * 5th and 6th bytes: Number of registers to read 116 116 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6. 117 117 118 -((( 119 119 How to parse the reading of the return command of the parameter: 120 -))) 121 121 122 -(% class="box infomessage" %) 123 -((( 124 124 Example:RETURN1:01 03 02 08 FD 7E 05 125 -))) 126 126 127 127 * The first byte ARD: slave address code (=001~254) 128 128 * The second byte: Return to read function code ... ... @@ -131,26 +131,22 @@ 131 131 * The 6th and 7th bytes: CRC16 checksum 132 132 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 133 133 104 + 134 134 === 1.3.3 How to configure RS485-LN and parse output commands === 135 135 136 136 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 137 137 138 -==== 1.3.3.1via AT COMMAND: ====109 +==== via AT COMMAND: ==== 139 139 140 -First, we can use **AT+CFGDEV**to get the return value, and we can also judge whether the input parameters are correct.111 +First, we can use AT+CFGDEV to get the return value, and we can also judge whether the input parameters are correct. 141 141 142 -((( 143 143 If the configured parameters and commands are incorrect, the return value is not obtained. 144 -))) 145 145 146 146 [[image:https://wiki.dragino.com/images/b/bc/AT_COMMAND1.png||height="358" width="456"]] 147 147 148 148 AT COMMAND 149 149 150 -(% class="box infomessage" %) 151 -((( 152 - AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 153 -))) 119 +AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 154 154 155 155 a: length for the return of AT+COMMAND 156 156 ... ... @@ -164,7 +164,6 @@ 164 164 165 165 PAYLOAD is available after the valid value is intercepted. 166 166 167 - 168 168 [[image:https://wiki.dragino.com/images/3/3a/AT_COMMAND4.png||height="219" width="576"]] 169 169 170 170 AT COMMAND ... ... @@ -171,56 +171,29 @@ 171 171 172 172 You can get configured PAYLOAD on TTN. 173 173 174 - 175 175 [[image:https://wiki.dragino.com/images/thumb/c/c2/AT_COMMAND3.png/600px-AT_COMMAND3.png||height="138" width="600"]] 176 176 177 -((( 178 178 AT COMMAND 179 -))) 180 180 181 -((( 182 - 183 -))) 143 +Example: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 184 184 185 -((( 186 -**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 187 -))) 188 - 189 -((( 190 190 RETURN1:01 03 02 00 02 39 85 00 00(return data) 191 -))) 192 192 193 -((( 194 194 AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 195 -))) 196 196 197 -((( 198 198 CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1 199 -))) 200 200 201 -((( 202 202 RETURN2:01 03 02 08 DC BE 1D(return data) 203 -))) 204 204 205 -((( 206 206 AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 207 -))) 208 208 209 -((( 210 210 CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 211 -))) 212 212 213 -((( 214 214 RETURN3:01 03 04 00 00 00 44 FA 00(return data) 215 -))) 216 216 217 -((( 218 218 AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 219 -))) 220 220 221 -((( 222 222 Payload:01 00 02 39 85 08 DC 00 00 00 44 223 -))) 224 224 225 225 [[image:https://wiki.dragino.com/images/thumb/9/9b/AT_COMMAND10.png/600px-AT_COMMAND10.png||height="278" width="600"]] 226 226 ... ... @@ -228,99 +228,58 @@ 228 228 229 229 01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy. 230 230 231 - 232 232 [[~[~[image:https://wiki.dragino.com/images/thumb/b/b8/AT_COMMAND11.png/600px-AT_COMMAND11.png~|~|height="271" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:AT_COMMAND11.png]] 233 233 234 234 AT COMMAND 235 235 173 +==== 1.3.3.1 via LoRaWAN DOWNLINK ==== 236 236 237 - ==== 1.3.3.2 viaLoRaWAN===175 +[[image:https://wiki.dragino.com/images/thumb/f/fc/DOWNLINK_METER1.png/600px-DOWNLINK_METER1.png||height="423" width="600"]] 238 238 239 -[[image:image-20220512104358-3.png]] 240 - 241 -((( 242 242 DOWNLINK 243 -))) 244 244 245 -((( 246 - 247 -))) 179 +Type Code 0xAF 248 248 249 -((( 250 -**Type Code 0xAF** 251 -))) 252 - 253 -((( 254 -(% class="box infomessage" %) 255 -((( 256 256 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 257 -))) 258 -))) 259 259 260 -((( 261 261 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 262 -))) 263 263 264 -((( 265 265 Format: AF MM NN LL XX XX XX XX YY 266 -))) 267 267 268 -((( 269 269 Where: 270 -))) 271 271 272 -((( 273 273 MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 274 -))) 275 275 276 -((( 277 277 NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 278 -))) 279 279 280 -((( 281 281 LL: The length of AT+COMMAND or AT+DATACUT command 282 -))) 283 283 284 -((( 285 285 XX XX XX XX: AT+COMMAND or AT+DATACUT command 286 -))) 287 287 288 -((( 289 289 YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN 290 -))) 291 291 292 -((( 293 293 will execute an uplink after got this command. 294 -))) 295 295 296 -((( 297 297 Example: 298 -))) 299 299 300 -((( 301 301 AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1 302 -))) 303 303 304 304 [[image:https://wiki.dragino.com/images/thumb/4/45/DOWNLINK_METER2.png/600px-DOWNLINK_METER2.png||height="208" width="600"]] 305 305 306 306 DOWNLINK 307 307 308 - 309 309 [[~[~[image:https://wiki.dragino.com/images/thumb/2/20/DOWNLINK_METER3.png/600px-DOWNLINK_METER3.png~|~|height="105" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER3.png]] 310 310 311 311 DOWNLINK 312 312 313 - 314 314 [[image:https://wiki.dragino.com/images/thumb/2/27/DOWNLINK_METER4.png/600px-DOWNLINK_METER4.png||height="210" width="600"]] 315 315 316 316 DOWNLINK 317 317 318 - 319 319 [[~[~[image:https://wiki.dragino.com/images/thumb/3/39/DOWNLINK_METER5.png/600px-DOWNLINK_METER5.png~|~|height="176" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER5.png]] 320 320 321 321 DOWNLINK 322 322 323 - 324 324 [[image:https://wiki.dragino.com/images/thumb/a/a2/DOWNLINK_METER6.png/600px-DOWNLINK_METER6.png||height="365" width="600"]] 325 325 326 326 DOWNLINK ... ... @@ -328,47 +328,30 @@ 328 328 329 329 === 1.3.4 How to configure and output commands for RS485 to USB === 330 330 331 -((( 332 332 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN. 333 -))) 334 334 335 -((( 336 336 First, connect the A+ and A- of the USB to the 485 A and 485 B of the energy meter. 337 -))) 338 338 339 -((( 340 340 Open the serial port debugging, set the send and receive to HEX. 341 -))) 342 342 343 -((( 344 344 Baud rate: 9600 345 -))) 346 346 347 -((( 348 348 check digit: Even 349 -))) 350 350 351 -[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height=" 725" width="544"]]238 +[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="800" width="600"]] 352 352 353 353 USB 354 354 242 +[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="800" width="600"]] 355 355 356 -[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="728" width="546"]] 357 - 358 358 USB 359 359 360 - 361 -((( 362 362 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 363 -))) 364 364 365 -((( 366 -**Example:** input:01 03 00 31 00 02 95 c4 367 -))) 248 +Example:input:01 03 00 31 00 02 95 c4 368 368 369 -((( 370 - output:01 03 04 00 00 00 42 7A 02 371 -))) 250 +{{{ output:01 03 04 00 00 00 42 7A 02 251 +}}} 372 372 373 373 [[image:https://wiki.dragino.com/images/thumb/b/b3/Usb_meter3.jpg/600px-Usb_meter3.jpg||height="466" width="600"]] 374 374 ... ... @@ -378,37 +378,21 @@ 378 378 379 379 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 380 380 381 -((( 382 -((( 383 383 Set the device address according to the parameters in the appendix of the MODBUS communication protocol. 384 -))) 385 -))) 386 386 387 387 [[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]] 388 388 389 - **Example**:These two meters are examples of setting parameters and device addresses.265 +Example:These two meters are examples of setting parameters and device addresses. 390 390 391 -[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height=" 737" width="553"]]267 +[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="800" width="600"]] 392 392 393 -[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height=" 733" width="550"]]269 +[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="800" width="600"]] 394 394 395 -((( 396 -((( 397 397 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. 398 -))) 399 -))) 400 400 401 -((( 402 -((( 403 403 We can use AT+CFGDEV to set the device address. 404 -))) 405 -))) 406 406 407 -((( 408 -((( 409 409 We modify the device address 01 of the first energy meter to 02. 410 -))) 411 -))) 412 412 413 413 [[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]] 414 414 ... ... @@ -443,6 +443,7 @@ 443 443 * 08 DF is the valid value of the meter with device address 02. 444 444 * 43 62 is the valid value of the meter with device address 01. 445 445 310 + 446 446 == 1.4 Example 4: Circuit Breaker Remote Open Close == 447 447 448 448 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -453,6 +453,7 @@ 453 453 454 454 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 455 455 321 + 456 456 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 457 457 458 458 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -461,6 +461,7 @@ 461 461 462 462 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 463 463 330 + 464 464 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 465 465 466 466 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -467,6 +467,7 @@ 467 467 468 468 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 469 469 337 + 470 470 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 471 471 472 472 [[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]]
- image-20220512104203-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -77.5 KB - Content
- image-20220512104238-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -81.2 KB - Content
- image-20220512104358-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -80.8 KB - Content
- image-20220512115601-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.4 KB - Content
- image-20220527091852-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -542.6 KB - Content
- image-20220527091942-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -608.5 KB - Content
- image-20220527092058-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -740.9 KB - Content
- image-20220527092146-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -686.5 KB - Content
- image-20220527092419-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -519.8 KB - Content
- image-20220527092514-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -819.1 KB - Content
- image-20220527092555-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -537.6 KB - Content
- image-20220527092629-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -9.1 KB - Content
- image-20220527092748-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.3 KB - Content
- image-20220527092936-10.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -11.3 KB - Content