Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,15 +11,17 @@ 11 11 12 12 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 13 13 14 -[[image: https://wiki.dragino.com/images/thumb/5/5c/RS485_01.png/600px-RS485_01.png||height="297" width="534"]]14 +[[image:image-20220527091852-1.png]] 15 15 16 16 Connection 17 17 18 18 19 -[[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %) 20 20 20 +[[image:image-20220527091942-2.png]](% style="display:none" %) 21 + 21 21 Connection 22 22 24 + 23 23 Related documents: 24 24 25 25 * [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure ... ... @@ -26,16 +26,17 @@ 26 26 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 27 27 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 28 28 31 + 29 29 == 1.2 Example 2: Connect to Pulse Counter == 30 30 31 31 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 32 32 33 -[[image: https://wiki.dragino.com/images/thumb/3/34/RS485_02_1.png/600px-RS485_02_1.png||height="364" width="600"]]36 +[[image:image-20220527092058-3.png]] 34 34 35 35 Connection 36 36 37 37 38 -[[image: https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]]41 +[[image:image-20220527092146-4.png]] 39 39 40 40 Connection 41 41 ... ... @@ -42,6 +42,9 @@ 42 42 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 43 43 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 44 44 48 +(% class="wikigeneratedid" %) 49 +== == 50 + 45 45 == 1.3 Example3: Use RS485-LN with energy meters == 46 46 47 47 === 1.3.1 OverView ===
- image-20220527092419-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +519.8 KB - Content