Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,7 +20,6 @@ 20 20 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 21 21 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 22 22 23 - 24 24 == 1.2 Example 2: Connect to Pulse Counter == 25 25 26 26 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -36,7 +36,6 @@ 36 36 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 37 37 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 38 38 39 - 40 40 == 1.3 Example3: Use RS485-LN with energy meters == 41 41 42 42 === 1.3.1 OverView === ... ... @@ -49,7 +49,7 @@ 49 49 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 50 50 ))) 51 51 52 -[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height=" 800" width="600"]]50 +[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height="726" width="545"]] 53 53 54 54 Connection1 55 55 ... ... @@ -65,7 +65,7 @@ 65 65 66 66 Once there is power, the RS485-LN will be on. 67 67 68 -[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="4 50" width="600"]]66 +[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]] 69 69 70 70 Connection2 71 71 ... ... @@ -105,7 +105,6 @@ 105 105 * The 6th and 7th bytes: CRC16 checksum 106 106 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 107 107 108 - 109 109 === 1.3.3 How to configure RS485-LN and parse output commands === 110 110 111 111 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. ... ... @@ -355,7 +355,6 @@ 355 355 * 08 DF is the valid value of the meter with device address 02. 356 356 * 43 62 is the valid value of the meter with device address 01. 357 357 358 - 359 359 == 1.4 Example 4: Circuit Breaker Remote Open Close == 360 360 361 361 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -366,7 +366,6 @@ 366 366 367 367 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 368 368 369 - 370 370 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 371 371 372 372 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -375,7 +375,6 @@ 375 375 376 376 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 377 377 378 - 379 379 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 380 380 381 381 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -382,7 +382,6 @@ 382 382 383 383 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 384 384 385 - 386 386 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 387 387 388 388 [[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]]