Last modified by Karry Zhuang on 2024/07/11 11:58
From version 1.5
edited by Xiaoling
on 2022/05/12 09:53
on 2022/05/12 09:53
Change comment:
There is no comment for this version
To version 61.1
edited by Bei Jinggeng
on 2023/08/08 15:16
on 2023/08/08 15:16
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 51 added, 0 removed)
- image-20220512104203-1.png
- image-20220512104238-2.png
- image-20220512104358-3.png
- image-20220512115601-1.png
- image-20220527091852-1.png
- image-20220527091942-2.png
- image-20220527092058-3.png
- image-20220527092146-4.png
- image-20220527092419-5.png
- image-20220527092514-6.png
- image-20220527092555-7.png
- image-20220527092629-8.png
- image-20220527092748-9.png
- image-20220527092936-10.png
- image-20220527093059-11.png
- image-20220527093133-12.png
- image-20220527093204-13.png
- image-20220527093251-14.png
- image-20220527093358-15.png
- image-20220527093430-16.png
- image-20220527093508-17.png
- image-20220527093530-18.png
- image-20220527093607-19.png
- image-20220527093628-20.png
- image-20220527093708-21.png
- image-20220527093747-22.png
- image-20220527093821-23.png
- image-20220527093849-24.png
- image-20220527093950-25.png
- image-20220527094028-26.png
- image-20220527094100-27.png
- image-20220527094150-28.png
- image-20220527094224-29.png
- image-20220527094330-30.png
- image-20220527094556-31.png
- image-20220601142044-1.png
- image-20220601142354-2.png
- image-20220601142452-3.png
- image-20220601142607-4.png
- image-20220601142805-5.png
- image-20220601142936-6.png
- image-20220601143046-7.png
- image-20220601143115-8.png
- image-20220601143201-9.png
- image-20220601143257-10.png
- image-20220601143519-1.png
- image-20220601143642-2.png
- image-20220601143803-3.png
- image-20220601143921-4.png
- image-20220601144053-5.png
- image-20220601144149-6.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -1,287 +1,496 @@ 1 +**Table of Contents:** 2 + 3 +{{toc/}} 4 + 5 + 6 + 7 + 8 + 9 + 1 1 = 1. Introduction = 2 2 12 + 3 3 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 4 4 15 + 5 5 == 1.1 Example 1: Connect to Leak relay and VFD == 6 6 18 + 7 7 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 8 8 9 -[[image:https://wiki.dragino.com/images/thumb/5/5c/RS485_01.png/600px-RS485_01.png||height="297" width="534"]] 10 10 11 - Connection22 +[[image:image-20220527091852-1.png||height="547" width="994"]] 12 12 13 - [[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %)24 +**Connection** 14 14 15 -Connection 16 16 17 -Related documents: 18 18 19 -* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure 20 -* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 28 +[[image:image-20220527091942-2.png]](% style="display:none" %) 29 + 30 +**Connection** 31 + 32 + 33 +(% style="color:blue" %)**Related documents:** 34 + 35 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 36 + 37 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 38 + 21 21 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 22 22 23 23 24 24 == 1.2 Example 2: Connect to Pulse Counter == 25 25 44 + 26 26 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 27 27 28 -[[image:https://wiki.dragino.com/images/thumb/3/34/RS485_02_1.png/600px-RS485_02_1.png||height="364" width="600"]] 29 29 30 - Connection48 +[[image:image-20220527092058-3.png||height="552" width="905"]] 31 31 32 - [[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]]50 +**Connection** 33 33 34 -Connection 35 35 36 -* [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 53 + 54 +[[image:image-20220527092146-4.png||height="507" width="906"]] 55 + 56 +**Connection** 57 + 58 + 59 +(% style="color:blue" %)**Related documents:** 60 + 61 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 62 + 37 37 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 38 38 39 39 40 -== 1.3 Example3: Use RS485-LN with energy meters == 66 +== 1.3 Example 3: Use RS485-LN with energy meters == 41 41 42 42 === 1.3.1 OverView === 43 43 70 + 44 44 ((( 45 -Note:The specifications of each energy meter are different, please refer to your own energy meter specifications. 72 +(% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.** 46 46 ))) 47 47 48 48 ((( 49 49 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 77 + 78 + 50 50 ))) 51 51 52 -[[image: https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height="800" width="600"]]81 +[[image:image-20220527092419-5.png]] 53 53 54 -Connection1 83 +**Connection1** 55 55 56 -How to connect with Energy Meter: 57 57 86 + 87 +((( 88 +(% style="color:blue" %)**How to connect with Energy Meter:** 89 + 90 + 91 +))) 92 + 93 +((( 58 58 Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively. 95 +))) 59 59 97 +((( 60 60 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 99 +))) 61 61 62 -Power Source VIN to RS485-LN VIN+ 101 +((( 102 +Power Source **VIN** to RS485-LN **VIN+** 103 +))) 63 63 64 -Power Source GND to RS485-LN VIN- 105 +((( 106 +Power Source **GND** to RS485-LN **VIN-** 107 +))) 65 65 109 +((( 66 66 Once there is power, the RS485-LN will be on. 67 67 68 -[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="450" width="600"]] 112 + 113 +))) 69 69 70 - Connection2115 +[[image:image-20220527092514-6.png]] 71 71 72 - [[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="800" width="600"]]117 +**Connection2** 73 73 74 -Connection3 75 75 76 76 121 +[[image:image-20220527092555-7.png]] 122 + 123 +**Connection3** 124 + 125 + 77 77 === 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 78 78 79 -If the user needs to read the parameters of the electric energy meter and use the modbus command, 80 80 81 -please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 129 +If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 82 82 83 -[[image: https://wiki.dragino.com/images/thumb/3/35/Meter4.png/600px-Meter4.png||alt="Meter4.png" height="193" width="600"]]131 +[[image:image-20220601143257-10.png]] 84 84 85 -Example:AT+COMMAND1=01 03 00 00 00 01 84 0A 86 86 134 +(% style="color:blue" %)**Example:**(%%) AT+COMMAND1=01 03 00 00 00 01 84 0A 135 + 87 87 * The first byte : slave address code (=001~247) 137 + 88 88 * The second byte : read register value function code 139 + 89 89 * 3rd and 4th bytes: start address of register to be read 141 + 90 90 * 5th and 6th bytes: Number of registers to read 143 + 91 91 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6. 92 92 146 +((( 147 + 148 + 149 + 93 93 How to parse the reading of the return command of the parameter: 94 94 95 -Example:RETURN1:01 03 02 08 FD 7E 05 152 +(% style="color:blue" %)**Example:**(%%) RETURN1:01 03 02 08 FD 7E 05 153 +))) 96 96 97 97 * The first byte ARD: slave address code (=001~254) 156 + 98 98 * The second byte: Return to read function code 158 + 99 99 * 3rd byte: total number of bytes 160 + 100 100 * 4th~5th bytes: register data 162 + 101 101 * The 6th and 7th bytes: CRC16 checksum 164 + 102 102 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 103 103 104 104 105 105 === 1.3.3 How to configure RS485-LN and parse output commands === 106 106 170 + 107 107 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 108 108 109 -==== via AT COMMAND: ==== 110 110 111 - First,wecanuseAT+CFGDEVto get the return value, and we can also judge whether the input parameters are correct.174 +==== **1.3.3.1 via AT COMMAND** ==== 112 112 176 + 177 +First, we can use (% style="color:blue" %)**AT+CFGDEV**(%%) to get the return value, and we can also judge whether the input parameters are correct. 178 + 179 +((( 113 113 If the configured parameters and commands are incorrect, the return value is not obtained. 114 114 115 -[[image:https://wiki.dragino.com/images/b/bc/AT_COMMAND1.png||height="358" width="456"]] 182 + 183 +))) 116 116 117 - AT COMMAND185 +[[image:image-20220601143201-9.png]] 118 118 119 -AT +DATACUTx :This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c187 +**AT COMMAND** 120 120 121 -a: length for the return of AT+COMMAND 122 122 123 -b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections. 190 +(% class="box infomessage" %) 191 +((( 192 + (% _mstmutation="1" %)**AT+DATACUTx **(%%): This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 193 +))) 124 124 125 - c:definethepositionforvalid value.195 +a: length for the return of AT+COMMAND 126 126 127 - [[image:https://wiki.dragino.com/images/7/7d/AT_COMMAND2.png||height="278" width="477"]]197 +b: 1: grab valid value by byte, max 6 bytes; 2: grab valid value by bytes section, max 3 sections. 128 128 129 - ATCOMMAND199 +c: define the position for valid value. 130 130 201 +[[image:image-20220601143115-8.png]] 202 + 203 +**AT COMMAND** 204 + 205 + 206 + 131 131 PAYLOAD is available after the valid value is intercepted. 132 132 133 -[[image: https://wiki.dragino.com/images/3/3a/AT_COMMAND4.png||height="219" width="576"]]209 +[[image:image-20220601143046-7.png]] 134 134 135 -AT COMMAND 211 +**AT COMMAND** 136 136 213 + 214 + 137 137 You can get configured PAYLOAD on TTN. 138 138 139 -[[image: https://wiki.dragino.com/images/thumb/c/c2/AT_COMMAND3.png/600px-AT_COMMAND3.png||height="138" width="600"]]217 +[[image:image-20220601143519-1.png]] 140 140 141 -AT COMMAND 219 +((( 220 +**AT COMMAND** 221 +))) 142 142 143 -Example: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 223 +((( 224 + 225 +))) 144 144 145 -RETURN1:01 03 02 00 02 39 85 00 00(return data) 227 +((( 228 +(% style="color:blue" %)**Example**: 146 146 147 -AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 230 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 231 +))) 148 148 149 -CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1 233 +((( 234 +RETURN1: 01 03 02 00 02 39 85 00 00(return data) 235 +))) 150 150 151 -RETURN2:01 03 02 08 DC BE 1D(return data) 237 +((( 238 +AT+DATACUT1: 9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 152 152 153 -AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 240 + 241 +))) 154 154 155 -CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 243 +((( 244 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 245 +))) 156 156 157 -RETURN3:01 03 04 00 00 00 44 FA 00(return data) 247 +((( 248 +RETURN2: 01 03 02 08 DC BE 1D(return data) 249 +))) 158 158 159 -AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 251 +((( 252 +AT+DATACUT2: 7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 160 160 161 -Payload:01 00 02 39 85 08 DC 00 00 00 44 254 + 255 +))) 162 162 163 -[[image:https://wiki.dragino.com/images/thumb/9/9b/AT_COMMAND10.png/600px-AT_COMMAND10.png||height="278" width="600"]] 257 +((( 258 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 259 +))) 164 164 261 +((( 262 +RETURN3: 01 03 04 00 00 00 44 FA 00(return data) 263 +))) 264 + 265 +((( 266 +AT+DATACUT3: 9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 267 +))) 268 + 269 +((( 270 +Payload: 01 00 02 39 85 08 DC 00 00 00 44 271 +))) 272 + 273 +[[image:image-20220601142936-6.png]] 274 + 165 165 AT COMMAND 166 166 167 -01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy. 168 168 169 -[[~[~[image:https://wiki.dragino.com/images/thumb/b/b8/AT_COMMAND11.png/600px-AT_COMMAND11.png~|~|height="271" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:AT_COMMAND11.png]] 170 170 279 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 280 + 281 + 282 +[[image:image-20220601143642-2.png]] 283 + 171 171 AT COMMAND 172 172 173 -==== 1.3.3.1 via LoRaWAN DOWNLINK ==== 174 174 175 -[[image:https://wiki.dragino.com/images/thumb/f/fc/DOWNLINK_METER1.png/600px-DOWNLINK_METER1.png||height="423" width="600"]] 176 176 177 -DOWNLINK 288 +==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 178 178 179 -Type Code 0xAF 180 180 291 +[[image:image-20220527093358-15.png]] 292 + 293 +((( 294 +**DOWNLINK** 295 +))) 296 + 297 + 298 + 299 +((( 300 +(% style="color:blue" %)**Type Code 0xAF** 301 +))) 302 + 303 +((( 304 +(% class="box infomessage" %) 305 +((( 181 181 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 307 +))) 308 +))) 182 182 183 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 310 +((( 311 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 312 +))) 184 184 314 +((( 185 185 Format: AF MM NN LL XX XX XX XX YY 316 +))) 186 186 318 +((( 187 187 Where: 320 +))) 188 188 322 +((( 189 189 MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 324 +))) 190 190 326 +((( 191 191 NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 328 +))) 192 192 330 +((( 193 193 LL: The length of AT+COMMAND or AT+DATACUT command 332 +))) 194 194 334 +((( 195 195 XX XX XX XX: AT+COMMAND or AT+DATACUT command 336 +))) 196 196 338 +((( 197 197 YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN 340 +))) 198 198 342 +((( 199 199 will execute an uplink after got this command. 344 +))) 200 200 201 -Example: 202 202 203 -AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1 347 +((( 348 +(% style="color:blue" %)**Example:** 349 +))) 204 204 205 -[[image:https://wiki.dragino.com/images/thumb/4/45/DOWNLINK_METER2.png/600px-DOWNLINK_METER2.png||height="208" width="600"]] 351 +((( 352 +**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 353 +))) 206 206 207 - DOWNLINK355 +[[image:image-20220601144149-6.png]] 208 208 209 - [[~[~[image:https://wiki.dragino.com/images/thumb/2/20/DOWNLINK_METER3.png/600px-DOWNLINK_METER3.png~|~|height="105" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER3.png]]357 +**DOWNLINK** 210 210 211 -DOWNLINK 212 212 213 -[[image:https://wiki.dragino.com/images/thumb/2/27/DOWNLINK_METER4.png/600px-DOWNLINK_METER4.png||height="210" width="600"]] 214 214 215 - DOWNLINK361 +[[image:image-20220601143803-3.png]] 216 216 217 - [[~[~[image:https://wiki.dragino.com/images/thumb/3/39/DOWNLINK_METER5.png/600px-DOWNLINK_METER5.png~|~|height="176" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER5.png]]363 +**DOWNLINK** 218 218 219 -DOWNLINK 220 220 221 -[[image:https://wiki.dragino.com/images/thumb/a/a2/DOWNLINK_METER6.png/600px-DOWNLINK_METER6.png||height="365" width="600"]] 222 222 223 -DOWNLINK 224 - 367 +[[image:image-20220601144053-5.png]] 225 225 369 +**DOWNLINK** 370 + 371 + 372 + 373 +[[image:image-20220601143921-4.png]] 374 + 375 +**DOWNLINK** 376 + 377 + 378 + 379 +[[image:image-20220601142805-5.png]] 380 + 381 +**DOWNLINK** 382 + 383 + 226 226 === 1.3.4 How to configure and output commands for RS485 to USB === 227 227 386 + 387 +((( 228 228 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN. 389 +))) 229 229 391 +((( 230 230 First, connect the A+ and A- of the USB to the 485 A and 485 B of the energy meter. 393 +))) 231 231 395 +((( 232 232 Open the serial port debugging, set the send and receive to HEX. 397 +))) 233 233 399 +((( 234 234 Baud rate: 9600 401 +))) 235 235 403 +((( 236 236 check digit: Even 237 237 238 -[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="800" width="600"]] 406 + 407 +))) 239 239 240 - USB409 +[[image:image-20220527093708-21.png]] 241 241 242 - [[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="800" width="600"]]411 +**USB** 243 243 244 -USB 245 245 414 + 415 +[[image:image-20220527093747-22.png]] 416 + 417 +**USB** 418 + 419 + 420 + 421 +((( 246 246 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 423 +))) 247 247 248 -Example:input:01 03 00 31 00 02 95 c4 425 +((( 426 +(% style="color:blue" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4 427 +))) 249 249 250 - {{{ output:01 03 04 00 00 00 42 7A 02251 - }}}429 +((( 430 + output:01 03 04 00 00 00 42 7A 02 252 252 253 -[[image:https://wiki.dragino.com/images/thumb/b/b3/Usb_meter3.jpg/600px-Usb_meter3.jpg||height="466" width="600"]] 432 + 433 +))) 254 254 255 - USB435 +[[image:image-20220527093821-23.png]] 256 256 437 +**USB** 438 + 439 + 440 + 257 257 === 1.3.5 How to configure multiple devices and modify device addresses === 258 258 443 + 259 259 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 260 260 446 +((( 447 +((( 261 261 Set the device address according to the parameters in the appendix of the MODBUS communication protocol. 449 +))) 450 +))) 262 262 263 -[[image: https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]]452 +[[image:image-20220601142044-1.png]] 264 264 265 -Example:These two meters are examples of setting parameters and device addresses. 266 266 267 - [[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg"height="800"width="600"]]455 +(% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 268 268 269 -[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="800" width="600"]] 270 270 458 +[[image:image-20220527093950-25.png]] 459 + 460 + 461 +[[image:image-20220527094028-26.png]] 462 + 463 + 464 +((( 465 +((( 271 271 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. 467 +))) 468 +))) 272 272 273 -We can use AT+CFGDEV to set the device address. 470 +((( 471 +((( 472 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address. 473 +))) 474 +))) 274 274 476 +((( 477 +((( 275 275 We modify the device address 01 of the first energy meter to 02. 479 +))) 480 +))) 276 276 277 -[[image: https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]]482 +[[image:image-20220601142354-2.png]] 278 278 279 -AT+CFGDEV:01 10 00 61 00 01 02 00 02,1 280 280 281 -* 01:device adaress 485 +(% class="box infomessage" %) 486 +((( 487 +**AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** 488 +))) 282 282 283 -* 10:functioncode490 +* 01: device adaress 284 284 492 +* 10: function code 493 + 285 285 * 00 61:Register address 286 286 287 287 * 00 01:Number of Registers ... ... @@ -298,47 +298,73 @@ 298 298 299 299 Its default device address is 01, and the following are the parameters for configuring two energy meters. 300 300 301 -[[image: https://wiki.dragino.com/images/1/13/Meter11.png||alt="Meter11.png" height="576" width="379"]]510 +[[image:image-20220601142452-3.png]] 302 302 303 -[[image:https://wiki.dragino.com/images/thumb/7/7e/Meter12.png/600px-Meter12.png||alt="Meter12.png" height="262" width="600"]] 304 304 305 - PAYLOAD:0108 DF 4362513 +[[image:image-20220601142607-4.png]] 306 306 515 + 516 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62** 517 + 307 307 * 08 DF is the valid value of the meter with device address 02. 308 308 * 43 62 is the valid value of the meter with device address 01. 309 309 521 +(% style="display:none" %) (%%) 310 310 523 + 311 311 == 1.4 Example 4: Circuit Breaker Remote Open Close == 312 312 313 -This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: 314 314 315 - [[image:https://wiki.dragino.com/images/thumb/f/fa/RS485_04_2.png/600px-RS485_04_2.png||height="336"width="600"]]527 +This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. 316 316 317 - Connection529 +The structure is like below: 318 318 319 - *[[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]: Configure Documen531 +[[image:image-20220527094330-30.png]] 320 320 533 +**Connection** 321 321 535 + 536 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 537 + 538 + 322 322 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 323 323 541 + 324 324 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 325 325 326 -* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf ]] : Configure Document ForRS485-BL544 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 327 327 328 -* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf ]] : Configure Documentfor RS485-LN546 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 329 329 330 330 331 -== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 549 +== 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 332 332 551 + 333 333 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 334 334 335 -* [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf ]] : Configure Document ForRS485-LN554 +* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 336 336 337 337 338 -== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 557 +== 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 339 339 340 -[[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]] 341 341 560 +[[image:image-20220527094556-31.png]] 561 + 562 + 342 342 Network Structure 343 343 344 344 * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]] 566 + 567 +== == 568 + 569 +== 1.8 Example 8: This sketch is supposed to test Dragino RS485-BL (Modbus master), using an Arduino UNO as a Modbus slave. == 570 + 571 +This sketch uses 4 registers: some of them can be set by Dragino with a command, another is used to store value from a DS18B20 temperature sensor, or a random generated number. All data is 16bit uint, but the sketch shows also how to represent booleans and negative numbers. 572 + 573 +In the next days I will be adding more documentation, but I think it already explains users how to build their own modbus sensor to pair with Dragino RS485-BL. 574 + 575 +This is released the code under GNU LGPL licence on Github: 576 + 577 +[[https:~~/~~/github.com/zorbaproject/ArduinoModbusForDraginoRS485>>url:https://github.com/zorbaproject/ArduinoModbusForDraginoRS485]] 578 + 579 +
- image-20220512104203-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.5 KB - Content
- image-20220512104238-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +81.2 KB - Content
- image-20220512104358-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +80.8 KB - Content
- image-20220512115601-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- image-20220527091852-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +542.6 KB - Content
- image-20220527091942-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +608.5 KB - Content
- image-20220527092058-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +740.9 KB - Content
- image-20220527092146-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +686.5 KB - Content
- image-20220527092419-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +519.8 KB - Content
- image-20220527092514-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +819.1 KB - Content
- image-20220527092555-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +537.6 KB - Content
- image-20220527092629-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- image-20220527092748-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.3 KB - Content
- image-20220527092936-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.3 KB - Content
- image-20220527093059-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.9 KB - Content
- image-20220527093133-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.1 KB - Content
- image-20220527093204-13.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content
- image-20220527093251-14.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- image-20220527093358-15.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.9 KB - Content
- image-20220527093430-16.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.9 KB - Content
- image-20220527093508-17.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.5 KB - Content
- image-20220527093530-18.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content
- image-20220527093607-19.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.3 KB - Content
- image-20220527093628-20.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.6 KB - Content
- image-20220527093708-21.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +569.4 KB - Content
- image-20220527093747-22.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +672.8 KB - Content
- image-20220527093821-23.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +161.5 KB - Content
- image-20220527093849-24.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.4 KB - Content
- image-20220527093950-25.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +624.4 KB - Content
- image-20220527094028-26.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +815.2 KB - Content
- image-20220527094100-27.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.3 KB - Content
- image-20220527094150-28.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.7 KB - Content
- image-20220527094224-29.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.8 KB - Content
- image-20220527094330-30.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +465.2 KB - Content
- image-20220527094556-31.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +162.5 KB - Content
- image-20220601142044-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.7 KB - Content
- image-20220601142354-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.8 KB - Content
- image-20220601142452-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.1 KB - Content
- image-20220601142607-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.9 KB - Content
- image-20220601142805-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- image-20220601142936-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.7 KB - Content
- image-20220601143046-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.2 KB - Content
- image-20220601143115-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.9 KB - Content
- image-20220601143201-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content
- image-20220601143257-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- image-20220601143519-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- image-20220601143642-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.4 KB - Content
- image-20220601143803-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content
- image-20220601143921-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- image-20220601144053-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.1 KB - Content
- image-20220601144149-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content