Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,7 +20,6 @@ 20 20 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 21 21 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 22 22 23 - 24 24 == 1.2 Example 2: Connect to Pulse Counter == 25 25 26 26 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -36,13 +36,12 @@ 36 36 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 37 37 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 38 38 39 - 40 40 == 1.3 Example3: Use RS485-LN with energy meters == 41 41 42 42 === 1.3.1 OverView === 43 43 44 44 ((( 45 -Note:The specifications of each energy meter are different, please refer to your own energy meter specifications. 43 +**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 46 46 ))) 47 47 48 48 ((( ... ... @@ -49,7 +49,7 @@ 49 49 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 50 50 ))) 51 51 52 -[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height=" 800" width="600"]]50 +[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height="726" width="545"]] 53 53 54 54 Connection1 55 55 ... ... @@ -65,7 +65,7 @@ 65 65 66 66 Once there is power, the RS485-LN will be on. 67 67 68 -[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="4 50" width="600"]]66 +[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]] 69 69 70 70 Connection2 71 71 ... ... @@ -76,13 +76,14 @@ 76 76 77 77 === 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 78 78 79 -If the user needs to read the parameters of the electric energy meter and use the modbus command, 77 +If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 80 80 81 -please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 82 - 83 83 [[image:https://wiki.dragino.com/images/thumb/3/35/Meter4.png/600px-Meter4.png||alt="Meter4.png" height="193" width="600"]] 84 84 81 +(% class="box infomessage" %) 82 +((( 85 85 Example:AT+COMMAND1=01 03 00 00 00 01 84 0A 84 +))) 86 86 87 87 * The first byte : slave address code (=001~247) 88 88 * The second byte : read register value function code ... ... @@ -92,7 +92,10 @@ 92 92 93 93 How to parse the reading of the return command of the parameter: 94 94 94 +(% class="box infomessage" %) 95 +((( 95 95 Example:RETURN1:01 03 02 08 FD 7E 05 97 +))) 96 96 97 97 * The first byte ARD: slave address code (=001~254) 98 98 * The second byte: Return to read function code ... ... @@ -101,22 +101,26 @@ 101 101 * The 6th and 7th bytes: CRC16 checksum 102 102 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 103 103 104 - 105 105 === 1.3.3 How to configure RS485-LN and parse output commands === 106 106 107 107 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 108 108 109 -==== via AT COMMAND: ==== 110 +==== 1.3.3.1 via AT COMMAND: ==== 110 110 111 -First, we can use AT+CFGDEV to get the return value, and we can also judge whether the input parameters are correct. 112 +First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct. 112 112 114 +((( 113 113 If the configured parameters and commands are incorrect, the return value is not obtained. 116 +))) 114 114 115 115 [[image:https://wiki.dragino.com/images/b/bc/AT_COMMAND1.png||height="358" width="456"]] 116 116 117 -AT COMMAND 120 +**AT COMMAND** 118 118 122 +(% class="box infomessage" %) 123 +((( 119 119 AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 125 +))) 120 120 121 121 a: length for the return of AT+COMMAND 122 122 ... ... @@ -130,6 +130,7 @@ 130 130 131 131 PAYLOAD is available after the valid value is intercepted. 132 132 139 + 133 133 [[image:https://wiki.dragino.com/images/3/3a/AT_COMMAND4.png||height="219" width="576"]] 134 134 135 135 AT COMMAND ... ... @@ -136,11 +136,12 @@ 136 136 137 137 You can get configured PAYLOAD on TTN. 138 138 146 + 139 139 [[image:https://wiki.dragino.com/images/thumb/c/c2/AT_COMMAND3.png/600px-AT_COMMAND3.png||height="138" width="600"]] 140 140 141 141 AT COMMAND 142 142 143 -Example: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 151 +**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 144 144 145 145 RETURN1:01 03 02 00 02 39 85 00 00(return data) 146 146 ... ... @@ -166,54 +166,91 @@ 166 166 167 167 01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy. 168 168 177 + 169 169 [[~[~[image:https://wiki.dragino.com/images/thumb/b/b8/AT_COMMAND11.png/600px-AT_COMMAND11.png~|~|height="271" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:AT_COMMAND11.png]] 170 170 171 171 AT COMMAND 172 172 173 -==== 1.3.3.1 via LoRaWAN DOWNLINK ==== 174 174 183 +==== 1.3.3.2 via LoRaWAN DOWNLINK ==== 184 + 175 175 [[image:https://wiki.dragino.com/images/thumb/f/fc/DOWNLINK_METER1.png/600px-DOWNLINK_METER1.png||height="423" width="600"]] 176 176 187 +((( 177 177 DOWNLINK 189 +))) 178 178 191 +((( 192 + 193 +))) 194 + 195 +((( 179 179 Type Code 0xAF 197 +))) 180 180 199 +((( 181 181 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 201 +))) 182 182 203 +((( 183 183 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 205 +))) 184 184 207 +((( 185 185 Format: AF MM NN LL XX XX XX XX YY 209 +))) 186 186 211 +((( 187 187 Where: 213 +))) 188 188 215 +((( 189 189 MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 217 +))) 190 190 219 +((( 191 191 NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 221 +))) 192 192 223 +((( 193 193 LL: The length of AT+COMMAND or AT+DATACUT command 225 +))) 194 194 227 +((( 195 195 XX XX XX XX: AT+COMMAND or AT+DATACUT command 229 +))) 196 196 231 +((( 197 197 YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN 233 +))) 198 198 235 +((( 199 199 will execute an uplink after got this command. 237 +))) 200 200 239 +((( 201 201 Example: 241 +))) 202 202 243 +((( 203 203 AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1 245 +))) 204 204 205 205 [[image:https://wiki.dragino.com/images/thumb/4/45/DOWNLINK_METER2.png/600px-DOWNLINK_METER2.png||height="208" width="600"]] 206 206 207 207 DOWNLINK 208 208 251 + 209 209 [[~[~[image:https://wiki.dragino.com/images/thumb/2/20/DOWNLINK_METER3.png/600px-DOWNLINK_METER3.png~|~|height="105" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER3.png]] 210 210 211 211 DOWNLINK 212 212 256 + 213 213 [[image:https://wiki.dragino.com/images/thumb/2/27/DOWNLINK_METER4.png/600px-DOWNLINK_METER4.png||height="210" width="600"]] 214 214 215 215 DOWNLINK 216 216 261 + 217 217 [[~[~[image:https://wiki.dragino.com/images/thumb/3/39/DOWNLINK_METER5.png/600px-DOWNLINK_METER5.png~|~|height="176" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER5.png]] 218 218 219 219 DOWNLINK ... ... @@ -307,7 +307,6 @@ 307 307 * 08 DF is the valid value of the meter with device address 02. 308 308 * 43 62 is the valid value of the meter with device address 01. 309 309 310 - 311 311 == 1.4 Example 4: Circuit Breaker Remote Open Close == 312 312 313 313 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -318,7 +318,6 @@ 318 318 319 319 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 320 320 321 - 322 322 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 323 323 324 324 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -327,7 +327,6 @@ 327 327 328 328 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 329 329 330 - 331 331 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 332 332 333 333 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -334,7 +334,6 @@ 334 334 335 335 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 336 336 337 - 338 338 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 339 339 340 340 [[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]]