Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,11 +6,11 @@ 6 6 7 7 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 8 8 9 -[[image:https://wiki.dragino.com/images/thumb/5/5c/RS485_01.png/600px-RS485_01.png||height=" 334" width="600"]]9 +[[image:https://wiki.dragino.com/images/thumb/5/5c/RS485_01.png/600px-RS485_01.png||height="297" width="534"]] 10 10 11 11 Connection 12 12 13 -[[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height=" 844" width="600"]]13 +[[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %) 14 14 15 15 Connection 16 16 ... ... @@ -20,7 +20,6 @@ 20 20 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 21 21 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 22 22 23 - 24 24 == 1.2 Example 2: Connect to Pulse Counter == 25 25 26 26 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -36,16 +36,19 @@ 36 36 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 37 37 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 38 38 39 - 40 40 == 1.3 Example3: Use RS485-LN with energy meters == 41 41 42 42 === 1.3.1 OverView === 43 43 44 -Note:The specifications of each energy meter are different, please refer to your own energy meter specifications. 42 +((( 43 +**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 44 +))) 45 45 46 +((( 46 46 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 48 +))) 47 47 48 -[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height=" 800" width="600"]]50 +[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height="726" width="545"]] 49 49 50 50 Connection1 51 51 ... ... @@ -61,7 +61,7 @@ 61 61 62 62 Once there is power, the RS485-LN will be on. 63 63 64 -[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="4 50" width="600"]]66 +[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]] 65 65 66 66 Connection2 67 67 ... ... @@ -72,13 +72,14 @@ 72 72 73 73 === 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 74 74 75 -If the user needs to read the parameters of the electric energy meter and use the modbus command, 77 +If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 76 76 77 -please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 78 - 79 79 [[image:https://wiki.dragino.com/images/thumb/3/35/Meter4.png/600px-Meter4.png||alt="Meter4.png" height="193" width="600"]] 80 80 81 +(% class="box infomessage" %) 82 +((( 81 81 Example:AT+COMMAND1=01 03 00 00 00 01 84 0A 84 +))) 82 82 83 83 * The first byte : slave address code (=001~247) 84 84 * The second byte : read register value function code ... ... @@ -88,7 +88,10 @@ 88 88 89 89 How to parse the reading of the return command of the parameter: 90 90 94 +(% class="box infomessage" %) 95 +((( 91 91 Example:RETURN1:01 03 02 08 FD 7E 05 97 +))) 92 92 93 93 * The first byte ARD: slave address code (=001~254) 94 94 * The second byte: Return to read function code ... ... @@ -97,22 +97,26 @@ 97 97 * The 6th and 7th bytes: CRC16 checksum 98 98 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 99 99 100 - 101 101 === 1.3.3 How to configure RS485-LN and parse output commands === 102 102 103 103 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 104 104 105 -==== via AT COMMAND: ==== 110 +==== 1.3.3.1 via AT COMMAND: ==== 106 106 107 -First, we can use AT+CFGDEV to get the return value, and we can also judge whether the input parameters are correct. 112 +First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct. 108 108 114 +((( 109 109 If the configured parameters and commands are incorrect, the return value is not obtained. 116 +))) 110 110 111 111 [[image:https://wiki.dragino.com/images/b/bc/AT_COMMAND1.png||height="358" width="456"]] 112 112 113 -AT COMMAND 120 +**AT COMMAND** 114 114 122 +(% class="box infomessage" %) 123 +((( 115 115 AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 125 +))) 116 116 117 117 a: length for the return of AT+COMMAND 118 118 ... ... @@ -126,6 +126,7 @@ 126 126 127 127 PAYLOAD is available after the valid value is intercepted. 128 128 139 + 129 129 [[image:https://wiki.dragino.com/images/3/3a/AT_COMMAND4.png||height="219" width="576"]] 130 130 131 131 AT COMMAND ... ... @@ -132,11 +132,12 @@ 132 132 133 133 You can get configured PAYLOAD on TTN. 134 134 146 + 135 135 [[image:https://wiki.dragino.com/images/thumb/c/c2/AT_COMMAND3.png/600px-AT_COMMAND3.png||height="138" width="600"]] 136 136 137 137 AT COMMAND 138 138 139 -Example: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 151 +**Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 140 140 141 141 RETURN1:01 03 02 00 02 39 85 00 00(return data) 142 142 ... ... @@ -162,54 +162,91 @@ 162 162 163 163 01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy. 164 164 177 + 165 165 [[~[~[image:https://wiki.dragino.com/images/thumb/b/b8/AT_COMMAND11.png/600px-AT_COMMAND11.png~|~|height="271" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:AT_COMMAND11.png]] 166 166 167 167 AT COMMAND 168 168 169 -==== 1.3.3.1 via LoRaWAN DOWNLINK ==== 170 170 183 +==== 1.3.3.2 via LoRaWAN DOWNLINK ==== 184 + 171 171 [[image:https://wiki.dragino.com/images/thumb/f/fc/DOWNLINK_METER1.png/600px-DOWNLINK_METER1.png||height="423" width="600"]] 172 172 187 +((( 173 173 DOWNLINK 189 +))) 174 174 191 +((( 192 + 193 +))) 194 + 195 +((( 175 175 Type Code 0xAF 197 +))) 176 176 199 +((( 177 177 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 201 +))) 178 178 203 +((( 179 179 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 205 +))) 180 180 207 +((( 181 181 Format: AF MM NN LL XX XX XX XX YY 209 +))) 182 182 211 +((( 183 183 Where: 213 +))) 184 184 215 +((( 185 185 MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 217 +))) 186 186 219 +((( 187 187 NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 221 +))) 188 188 223 +((( 189 189 LL: The length of AT+COMMAND or AT+DATACUT command 225 +))) 190 190 227 +((( 191 191 XX XX XX XX: AT+COMMAND or AT+DATACUT command 229 +))) 192 192 231 +((( 193 193 YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN 233 +))) 194 194 235 +((( 195 195 will execute an uplink after got this command. 237 +))) 196 196 239 +((( 197 197 Example: 241 +))) 198 198 243 +((( 199 199 AF 03 01 06 0A 05 00 04 00 01 00: Same as AT+COMMAND3=0A 05 00 04 00 01,1 245 +))) 200 200 201 201 [[image:https://wiki.dragino.com/images/thumb/4/45/DOWNLINK_METER2.png/600px-DOWNLINK_METER2.png||height="208" width="600"]] 202 202 203 203 DOWNLINK 204 204 251 + 205 205 [[~[~[image:https://wiki.dragino.com/images/thumb/2/20/DOWNLINK_METER3.png/600px-DOWNLINK_METER3.png~|~|height="105" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER3.png]] 206 206 207 207 DOWNLINK 208 208 256 + 209 209 [[image:https://wiki.dragino.com/images/thumb/2/27/DOWNLINK_METER4.png/600px-DOWNLINK_METER4.png||height="210" width="600"]] 210 210 211 211 DOWNLINK 212 212 261 + 213 213 [[~[~[image:https://wiki.dragino.com/images/thumb/3/39/DOWNLINK_METER5.png/600px-DOWNLINK_METER5.png~|~|height="176" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:DOWNLINK_METER5.png]] 214 214 215 215 DOWNLINK ... ... @@ -303,7 +303,6 @@ 303 303 * 08 DF is the valid value of the meter with device address 02. 304 304 * 43 62 is the valid value of the meter with device address 01. 305 305 306 - 307 307 == 1.4 Example 4: Circuit Breaker Remote Open Close == 308 308 309 309 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -314,7 +314,6 @@ 314 314 315 315 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 316 316 317 - 318 318 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 319 319 320 320 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -323,7 +323,6 @@ 323 323 324 324 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 325 325 326 - 327 327 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 328 328 329 329 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -330,7 +330,6 @@ 330 330 331 331 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 332 332 333 - 334 334 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 335 335 336 336 [[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]]