... ... @@ -10,7 +10,6 @@
10 10  
11 11  Connection
12 12  
13 -
14 14  [[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %)
15 15  
16 16  Connection
... ... @@ -29,7 +29,6 @@
29 29  
30 30  Connection
31 31  
32 -
33 33  [[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]]
34 34  
35 35  Connection
... ... @@ -69,9 +69,8 @@
69 69  
70 70  Connection2
71 71  
70 +[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="800" width="600"]]
72 72  
73 -[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="712" width="534"]]
74 -
75 75  Connection3
76 76  
77 77  
... ... @@ -92,9 +92,7 @@
92 92  * 5th and 6th bytes: Number of registers to read
93 93  * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6.
94 94  
95 -(((
96 96  How to parse the reading of the return command of the parameter:
97 -)))
98 98  
99 99  (% class="box infomessage" %)
100 100  (((
... ... @@ -122,7 +122,7 @@
122 122  
123 123  [[image:https://wiki.dragino.com/images/b/bc/AT_COMMAND1.png||height="358" width="456"]]
124 124  
125 -AT COMMAND
120 +**AT COMMAND**
126 126  
127 127  (% class="box infomessage" %)
128 128  (((
... ... @@ -151,53 +151,27 @@
151 151  
152 152  [[image:https://wiki.dragino.com/images/thumb/c/c2/AT_COMMAND3.png/600px-AT_COMMAND3.png||height="138" width="600"]]
153 153  
154 -(((
155 155  AT COMMAND
156 -)))
157 157  
158 -(((
159 -
160 -)))
161 -
162 -(((
163 163  **Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
164 -)))
165 165  
166 -(((
167 167  RETURN1:01 03 02 00 02 39 85 00 00(return data)
168 -)))
169 169  
170 -(((
171 171  AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload.
172 -)))
173 173  
174 -(((
175 175  CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1
176 -)))
177 177  
178 -(((
179 179  RETURN2:01 03 02 08 DC BE 1D(return data)
180 -)))
181 181  
182 -(((
183 183  AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload.
184 -)))
185 185  
186 -(((
187 187  CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
188 -)))
189 189  
190 -(((
191 191  RETURN3:01 03 04 00 00 00 44 FA 00(return data)
192 -)))
193 193  
194 -(((
195 195  AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload.
196 -)))
197 197  
198 -(((
199 199  Payload:01 00 02 39 85 08 DC 00 00 00 44
200 -)))
201 201  
202 202  [[image:https://wiki.dragino.com/images/thumb/9/9b/AT_COMMAND10.png/600px-AT_COMMAND10.png||height="278" width="600"]]
203 203  
... ... @@ -294,7 +294,6 @@
294 294  
295 295  DOWNLINK
296 296  
297 -
298 298  [[image:https://wiki.dragino.com/images/thumb/a/a2/DOWNLINK_METER6.png/600px-DOWNLINK_METER6.png||height="365" width="600"]]
299 299  
300 300  DOWNLINK
... ... @@ -302,47 +302,30 @@
302 302  
303 303  === 1.3.4 How to configure and output commands for RS485 to USB ===
304 304  
305 -(((
306 306  This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN.
307 -)))
308 308  
309 -(((
310 310  First, connect the A+ and A- of the USB to the 485 A and 485 B of the energy meter.
311 -)))
312 312  
313 -(((
314 314  Open the serial port debugging, set the send and receive to HEX.
315 -)))
316 316  
317 -(((
318 318  Baud rate: 9600
319 -)))
320 320  
321 -(((
322 322  check digit: Even
323 -)))
324 324  
325 -[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="725" width="544"]]
283 +[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="800" width="600"]]
326 326  
327 327  USB
328 328  
287 +[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="800" width="600"]]
329 329  
330 -[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="728" width="546"]]
331 -
332 332  USB
333 333  
334 -
335 -(((
336 336  The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command.
337 -)))
338 338  
339 -(((
340 -**Example:**  input:01 03 00 31 00 02 95 c4
341 -)))
293 +Example:input:01 03 00 31 00 02 95 c4
342 342  
343 -(((
344 - output:01 03 04 00 00 00 42 7A 02
345 -)))
295 +{{{ output:01 03 04 00 00 00 42 7A 02
296 +}}}
346 346  
347 347  [[image:https://wiki.dragino.com/images/thumb/b/b3/Usb_meter3.jpg/600px-Usb_meter3.jpg||height="466" width="600"]]
348 348  
... ... @@ -352,37 +352,21 @@
352 352  
353 353  If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01.
354 354  
355 -(((
356 -(((
357 357  Set the device address according to the parameters in the appendix of the MODBUS communication protocol.
358 -)))
359 -)))
360 360  
361 361  [[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]]
362 362  
363 -**Example**:These two meters are examples of setting parameters and device addresses.
310 +Example:These two meters are examples of setting parameters and device addresses.
364 364  
365 -[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="737" width="553"]]
312 +[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="800" width="600"]]
366 366  
367 -[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]]
314 +[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="800" width="600"]]
368 368  
369 -(((
370 -(((
371 371  First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address.
372 -)))
373 -)))
374 374  
375 -(((
376 -(((
377 377  We can use AT+CFGDEV to set the device address.
378 -)))
379 -)))
380 380  
381 -(((
382 -(((
383 383  We modify the device address 01 of the first energy meter to 02.
384 -)))
385 -)))
386 386  
387 387  [[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]]
388 388  