<
From version < 1.17 >
edited by Xiaoling
on 2022/05/12 10:21
To version < 4.7 >
edited by Xiaoling
on 2022/05/12 10:46
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,6 +10,7 @@
10 10  
11 11  Connection
12 12  
13 +
13 13  [[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %)
14 14  
15 15  Connection
... ... @@ -28,6 +28,7 @@
28 28  
29 29  Connection
30 30  
32 +
31 31  [[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]]
32 32  
33 33  Connection
... ... @@ -51,17 +51,29 @@
51 51  
52 52  Connection1
53 53  
56 +(((
54 54  How to connect with Energy Meter:
58 +)))
55 55  
60 +(((
56 56  Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively.
62 +)))
57 57  
64 +(((
58 58  The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
66 +)))
59 59  
68 +(((
60 60  Power Source VIN to RS485-LN VIN+
70 +)))
61 61  
72 +(((
62 62  Power Source GND to RS485-LN VIN-
74 +)))
63 63  
76 +(((
64 64  Once there is power, the RS485-LN will be on.
78 +)))
65 65  
66 66  [[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]]
67 67  
... ... @@ -124,7 +124,7 @@
124 124  
125 125  (% class="box infomessage" %)
126 126  (((
127 -AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
141 + AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
128 128  )))
129 129  
130 130  a: length for the return of AT+COMMAND
... ... @@ -211,7 +211,7 @@
211 211  
212 212  ==== 1.3.3.2 via LoRaWAN DOWNLINK ====
213 213  
214 -[[image:https://wiki.dragino.com/images/thumb/f/fc/DOWNLINK_METER1.png/600px-DOWNLINK_METER1.png||height="423" width="600"]]
228 +[[image:image-20220512104358-3.png]]
215 215  
216 216  (((
217 217  DOWNLINK
... ... @@ -222,12 +222,15 @@
222 222  )))
223 223  
224 224  (((
225 -Type Code 0xAF
239 +**Type Code 0xAF**
226 226  )))
227 227  
228 228  (((
243 +(% class="box infomessage" %)
244 +(((
229 229  0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
230 230  )))
247 +)))
231 231  
232 232  (((
233 233  Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
... ... @@ -339,7 +339,7 @@
339 339  )))
340 340  
341 341  (((
342 - output:01 03 04 00 00 00 42 7A 02
359 + output01 03 04 00 00 00 42 7A 02
343 343  )))
344 344  
345 345  [[image:https://wiki.dragino.com/images/thumb/b/b3/Usb_meter3.jpg/600px-Usb_meter3.jpg||height="466" width="600"]]
image-20220512104203-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +77.5 KB
Content
image-20220512104238-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +81.2 KB
Content
image-20220512104358-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +80.8 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0