<
From version < 1.15 >
edited by Xiaoling
on 2022/05/12 10:19
To version < 4.1 >
edited by Xiaoling
on 2022/05/12 10:43
>
Change comment: Uploaded new attachment "image-20220512104358-3.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -10,6 +10,7 @@
10 10  
11 11  Connection
12 12  
13 +
13 13  [[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %)
14 14  
15 15  Connection
... ... @@ -28,6 +28,7 @@
28 28  
29 29  Connection
30 30  
32 +
31 31  [[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]]
32 32  
33 33  Connection
... ... @@ -51,17 +51,29 @@
51 51  
52 52  Connection1
53 53  
56 +(((
54 54  How to connect with Energy Meter:
58 +)))
55 55  
60 +(((
56 56  Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively.
62 +)))
57 57  
64 +(((
58 58  The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
66 +)))
59 59  
68 +(((
60 60  Power Source VIN to RS485-LN VIN+
70 +)))
61 61  
72 +(((
62 62  Power Source GND to RS485-LN VIN-
74 +)))
63 63  
76 +(((
64 64  Once there is power, the RS485-LN will be on.
78 +)))
65 65  
66 66  [[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]]
67 67  
... ... @@ -124,7 +124,7 @@
124 124  
125 125  (% class="box infomessage" %)
126 126  (((
127 -AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
141 + AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
128 128  )))
129 129  
130 130  a: length for the return of AT+COMMAND
... ... @@ -358,23 +358,29 @@
358 358  
359 359  [[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]]
360 360  
361 -Example:These two meters are examples of setting parameters and device addresses.
375 +**Example**:These two meters are examples of setting parameters and device addresses.
362 362  
363 -[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="800" width="600"]]
377 +[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="737" width="553"]]
364 364  
365 365  [[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]]
366 366  
367 367  (((
382 +(((
368 368  First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address.
369 369  )))
385 +)))
370 370  
371 371  (((
388 +(((
372 372  We can use AT+CFGDEV to set the device address.
373 373  )))
391 +)))
374 374  
375 375  (((
394 +(((
376 376  We modify the device address 01 of the first energy meter to 02.
377 377  )))
397 +)))
378 378  
379 379  [[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]]
380 380  
image-20220512104203-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +77.5 KB
Content
image-20220512104238-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +81.2 KB
Content
image-20220512104358-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +80.8 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0