Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,6 +10,7 @@ 10 10 11 11 Connection 12 12 13 + 13 13 [[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %) 14 14 15 15 Connection ... ... @@ -28,6 +28,7 @@ 28 28 29 29 Connection 30 30 32 + 31 31 [[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]] 32 32 33 33 Connection ... ... @@ -51,17 +51,29 @@ 51 51 52 52 Connection1 53 53 56 +((( 54 54 How to connect with Energy Meter: 58 +))) 55 55 60 +((( 56 56 Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively. 62 +))) 57 57 64 +((( 58 58 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 66 +))) 59 59 68 +((( 60 60 Power Source VIN to RS485-LN VIN+ 70 +))) 61 61 72 +((( 62 62 Power Source GND to RS485-LN VIN- 74 +))) 63 63 76 +((( 64 64 Once there is power, the RS485-LN will be on. 78 +))) 65 65 66 66 [[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]] 67 67 ... ... @@ -124,7 +124,7 @@ 124 124 125 125 (% class="box infomessage" %) 126 126 ((( 127 -AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 141 + AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 128 128 ))) 129 129 130 130 a: length for the return of AT+COMMAND ... ... @@ -358,23 +358,29 @@ 358 358 359 359 [[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]] 360 360 361 -Example:These two meters are examples of setting parameters and device addresses. 375 +**Example**:These two meters are examples of setting parameters and device addresses. 362 362 363 -[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height=" 800" width="600"]]377 +[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="737" width="553"]] 364 364 365 365 [[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]] 366 366 367 367 ((( 382 +((( 368 368 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. 369 369 ))) 385 +))) 370 370 371 371 ((( 388 +((( 372 372 We can use AT+CFGDEV to set the device address. 373 373 ))) 391 +))) 374 374 375 375 ((( 394 +((( 376 376 We modify the device address 01 of the first energy meter to 02. 377 377 ))) 397 +))) 378 378 379 379 [[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]] 380 380
- image-20220512104203-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.5 KB - Content