<
From version < 1.13 >
edited by Xiaoling
on 2022/05/12 10:15
To version < 3.1 >
edited by Xiaoling
on 2022/05/12 10:42
>
Change comment: Uploaded new attachment "image-20220512104238-2.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -10,6 +10,7 @@
10 10  
11 11  Connection
12 12  
13 +
13 13  [[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %)
14 14  
15 15  Connection
... ... @@ -28,6 +28,7 @@
28 28  
29 29  Connection
30 30  
32 +
31 31  [[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]]
32 32  
33 33  Connection
... ... @@ -51,17 +51,29 @@
51 51  
52 52  Connection1
53 53  
56 +(((
54 54  How to connect with Energy Meter:
58 +)))
55 55  
60 +(((
56 56  Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively.
62 +)))
57 57  
64 +(((
58 58  The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
66 +)))
59 59  
68 +(((
60 60  Power Source VIN to RS485-LN VIN+
70 +)))
61 61  
72 +(((
62 62  Power Source GND to RS485-LN VIN-
74 +)))
63 63  
76 +(((
64 64  Once there is power, the RS485-LN will be on.
78 +)))
65 65  
66 66  [[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]]
67 67  
... ... @@ -68,7 +68,7 @@
68 68  Connection2
69 69  
70 70  
71 -[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="763" width="573"]]
85 +[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="712" width="534"]]
72 72  
73 73  Connection3
74 74  
... ... @@ -124,7 +124,7 @@
124 124  
125 125  (% class="box infomessage" %)
126 126  (((
127 -AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
141 + AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
128 128  )))
129 129  
130 130  a: length for the return of AT+COMMAND
... ... @@ -292,6 +292,7 @@
292 292  
293 293  DOWNLINK
294 294  
309 +
295 295  [[image:https://wiki.dragino.com/images/thumb/a/a2/DOWNLINK_METER6.png/600px-DOWNLINK_METER6.png||height="365" width="600"]]
296 296  
297 297  DOWNLINK
... ... @@ -319,12 +319,12 @@
319 319  check digit: Even
320 320  )))
321 321  
322 -[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="800" width="600"]]
337 +[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="725" width="544"]]
323 323  
324 324  USB
325 325  
326 326  
327 -[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="800" width="600"]]
342 +[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="728" width="546"]]
328 328  
329 329  USB
330 330  
... ... @@ -349,21 +349,37 @@
349 349  
350 350  If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01.
351 351  
367 +(((
368 +(((
352 352  Set the device address according to the parameters in the appendix of the MODBUS communication protocol.
370 +)))
371 +)))
353 353  
354 354  [[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]]
355 355  
356 -Example:These two meters are examples of setting parameters and device addresses.
375 +**Example**:These two meters are examples of setting parameters and device addresses.
357 357  
358 -[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="800" width="600"]]
377 +[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="737" width="553"]]
359 359  
360 -[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="800" width="600"]]
379 +[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]]
361 361  
381 +(((
382 +(((
362 362  First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address.
384 +)))
385 +)))
363 363  
387 +(((
388 +(((
364 364  We can use AT+CFGDEV to set the device address.
390 +)))
391 +)))
365 365  
393 +(((
394 +(((
366 366  We modify the device address 01 of the first energy meter to 02.
396 +)))
397 +)))
367 367  
368 368  [[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]]
369 369  
image-20220512104203-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +77.5 KB
Content
image-20220512104238-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +81.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0