<
From version < 1.12 >
edited by Xiaoling
on 2022/05/12 10:13
To version < 1.15 >
edited by Xiaoling
on 2022/05/12 10:19
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -68,7 +68,7 @@
68 68  Connection2
69 69  
70 70  
71 -[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="763" width="573"]]
71 +[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="712" width="534"]]
72 72  
73 73  Connection3
74 74  
... ... @@ -154,6 +154,10 @@
154 154  )))
155 155  
156 156  (((
157 +
158 +)))
159 +
160 +(((
157 157  **Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
158 158  )))
159 159  
... ... @@ -288,6 +288,7 @@
288 288  
289 289  DOWNLINK
290 290  
295 +
291 291  [[image:https://wiki.dragino.com/images/thumb/a/a2/DOWNLINK_METER6.png/600px-DOWNLINK_METER6.png||height="365" width="600"]]
292 292  
293 293  DOWNLINK
... ... @@ -295,30 +295,47 @@
295 295  
296 296  === 1.3.4 How to configure and output commands for RS485 to USB ===
297 297  
303 +(((
298 298  This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN.
305 +)))
299 299  
307 +(((
300 300  First, connect the A+ and A- of the USB to the 485 A and 485 B of the energy meter.
309 +)))
301 301  
311 +(((
302 302  Open the serial port debugging, set the send and receive to HEX.
313 +)))
303 303  
315 +(((
304 304  Baud rate: 9600
317 +)))
305 305  
319 +(((
306 306  check digit: Even
321 +)))
307 307  
308 -[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="800" width="600"]]
323 +[[image:https://wiki.dragino.com/images/thumb/8/8f/Usb_meter2.jpg/600px-Usb_meter2.jpg||height="725" width="544"]]
309 309  
310 310  USB
311 311  
312 -[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="800" width="600"]]
313 313  
328 +[[image:https://wiki.dragino.com/images/thumb/6/62/Usb_meter1.jpg/600px-Usb_meter1.jpg||height="728" width="546"]]
329 +
314 314  USB
315 315  
332 +
333 +(((
316 316  The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command.
335 +)))
317 317  
318 -Example:input:01 03 00 31 00 02 95 c4
337 +(((
338 +**Example:**  input:01 03 00 31 00 02 95 c4
339 +)))
319 319  
320 -{{{ output:01 03 04 00 00 00 42 7A 02
321 -}}}
341 +(((
342 + output:01 03 04 00 00 00 42 7A 02
343 +)))
322 322  
323 323  [[image:https://wiki.dragino.com/images/thumb/b/b3/Usb_meter3.jpg/600px-Usb_meter3.jpg||height="466" width="600"]]
324 324  
... ... @@ -328,7 +328,11 @@
328 328  
329 329  If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01.
330 330  
353 +(((
354 +(((
331 331  Set the device address according to the parameters in the appendix of the MODBUS communication protocol.
356 +)))
357 +)))
332 332  
333 333  [[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]]
334 334  
... ... @@ -336,13 +336,19 @@
336 336  
337 337  [[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="800" width="600"]]
338 338  
339 -[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="800" width="600"]]
365 +[[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]]
340 340  
367 +(((
341 341  First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address.
369 +)))
342 342  
371 +(((
343 343  We can use AT+CFGDEV to set the device address.
373 +)))
344 344  
375 +(((
345 345  We modify the device address 01 of the first energy meter to 02.
377 +)))
346 346  
347 347  [[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]]
348 348  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0