Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,6 +20,7 @@ 20 20 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 21 21 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 22 22 23 + 23 23 == 1.2 Example 2: Connect to Pulse Counter == 24 24 25 25 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -35,6 +35,7 @@ 35 35 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 36 36 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 37 37 39 + 38 38 == 1.3 Example3: Use RS485-LN with energy meters == 39 39 40 40 === 1.3.1 OverView === ... ... @@ -47,7 +47,7 @@ 47 47 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 48 48 ))) 49 49 50 -[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height=" 726" width="545"]]52 +[[image:https://wiki.dragino.com/images/thumb/f/f4/Meter1.jpg/600px-Meter1.jpg||height="800" width="600"]] 51 51 52 52 Connection1 53 53 ... ... @@ -63,13 +63,12 @@ 63 63 64 64 Once there is power, the RS485-LN will be on. 65 65 66 -[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="4 33" width="577"]]68 +[[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="450" width="600"]] 67 67 68 68 Connection2 69 69 72 +[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="800" width="600"]] 70 70 71 -[[image:https://wiki.dragino.com/images/thumb/a/a5/Meter3.jpg/600px-Meter3.jpg||height="763" width="573"]] 72 - 73 73 Connection3 74 74 75 75 ... ... @@ -90,9 +90,7 @@ 90 90 * 5th and 6th bytes: Number of registers to read 91 91 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6. 92 92 93 -((( 94 94 How to parse the reading of the return command of the parameter: 95 -))) 96 96 97 97 (% class="box infomessage" %) 98 98 ((( ... ... @@ -106,6 +106,7 @@ 106 106 * The 6th and 7th bytes: CRC16 checksum 107 107 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage. 108 108 108 + 109 109 === 1.3.3 How to configure RS485-LN and parse output commands === 110 110 111 111 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. ... ... @@ -120,7 +120,7 @@ 120 120 121 121 [[image:https://wiki.dragino.com/images/b/bc/AT_COMMAND1.png||height="358" width="456"]] 122 122 123 -AT COMMAND 123 +**AT COMMAND** 124 124 125 125 (% class="box infomessage" %) 126 126 ((( ... ... @@ -149,49 +149,27 @@ 149 149 150 150 [[image:https://wiki.dragino.com/images/thumb/c/c2/AT_COMMAND3.png/600px-AT_COMMAND3.png||height="138" width="600"]] 151 151 152 -((( 153 153 AT COMMAND 154 -))) 155 155 156 -((( 157 157 **Example**: CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 158 -))) 159 159 160 -((( 161 161 RETURN1:01 03 02 00 02 39 85 00 00(return data) 162 -))) 163 163 164 -((( 165 165 AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 166 -))) 167 167 168 -((( 169 169 CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1 170 -))) 171 171 172 -((( 173 173 RETURN2:01 03 02 08 DC BE 1D(return data) 174 -))) 175 175 176 -((( 177 177 AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 178 -))) 179 179 180 -((( 181 181 CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 182 -))) 183 183 184 -((( 185 185 RETURN3:01 03 04 00 00 00 44 FA 00(return data) 186 -))) 187 187 188 -((( 189 189 AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 190 -))) 191 191 192 -((( 193 193 Payload:01 00 02 39 85 08 DC 00 00 00 44 194 -))) 195 195 196 196 [[image:https://wiki.dragino.com/images/thumb/9/9b/AT_COMMAND10.png/600px-AT_COMMAND10.png||height="278" width="600"]] 197 197 ... ... @@ -377,6 +377,7 @@ 377 377 * 08 DF is the valid value of the meter with device address 02. 378 378 * 43 62 is the valid value of the meter with device address 01. 379 379 358 + 380 380 == 1.4 Example 4: Circuit Breaker Remote Open Close == 381 381 382 382 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -387,6 +387,7 @@ 387 387 388 388 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 389 389 369 + 390 390 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 391 391 392 392 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: ... ... @@ -395,6 +395,7 @@ 395 395 396 396 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 397 397 378 + 398 398 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 399 399 400 400 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -401,6 +401,7 @@ 401 401 402 402 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 403 403 385 + 404 404 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 405 405 406 406 [[image:https://wiki.dragino.com/images/thumb/9/97/PLC_M221.png/600px-PLC_M221.png||height="353" width="600"]]