9
10
11 = **1. Introduction** =
12
13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
14
15
16 == **1.1 Example 1: Connect to Leak relay and VFD** ==
17
18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
19
20 [[image:image-20220527091852-1.png]]
21
22 Connection
23
24
25
26 [[image:image-20220527091942-2.png]](% style="display:none" %)
27
28 Connection
29
30
31 Related documents:
32
33 * [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure
34 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
36
37
38
39 == **1.2 Example 2: Connect to Pulse Counter** ==
40
41 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
42
43 [[image:image-20220527092058-3.png]]
44
45 Connection
46
47
48
49 [[image:image-20220527092146-4.png]]
50
51 Connection
52
53
54 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document
55 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
56
57 == ==
58
59 == **1.3 Example3: Use RS485-LN with energy meters** ==
60
61 === **1.3.1 OverView** ===
62
63 (((
64 **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.
65 )))
66
67 (((
68 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter.
69 )))
70
71 [[image:image-20220527092419-5.png]]
72
73 Connection1
74
75
76
77 (((
78 How to connect with Energy Meter:
79 )))
80
81 (((
82 Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively.
83 )))
84
85 (((
86 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
87 )))
88
89 (((
90 Power Source VIN to RS485-LN VIN+
91 )))
92
93 (((
94 Power Source GND to RS485-LN VIN-
95 )))
96
97 (((
98 Once there is power, the RS485-LN will be on.
99 )))
100
101 [[image:image-20220527092514-6.png]]
102
103 Connection2
104
105
106
107 [[image:image-20220527092555-7.png]]
108
109 Connection3
110
111
112 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
113
114 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter.
115
116 [[image:image-20220527092629-8.png]]
117
118
119 (% class="box infomessage" %)
120 (((
121 **Example:** AT+COMMAND1=01 03 00 00 00 01 84 0A
122 )))
123
124 * The first byte : slave address code (=001~247)
125 * The second byte : read register value function code
126 * 3rd and 4th bytes: start address of register to be read
127 * 5th and 6th bytes: Number of registers to read
128 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6.
129
130 (((
131 How to parse the reading of the return command of the parameter:
132 )))
133
134 (% class="box infomessage" %)
135 (((
136 **Example:** RETURN1:01 03 02 08 FD 7E 05
137 )))
138
139 * The first byte ARD: slave address code (=001~254)
140 * The second byte: Return to read function code
141 * 3rd byte: total number of bytes
142 * 4th~5th bytes: register data
143 * The 6th and 7th bytes: CRC16 checksum
144 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage.
145
146 (% class="wikigeneratedid" %)
147 (((
148
149 )))
150
151 === **1.3.3 How to configure RS485-LN and parse output commands** ===
152
153 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
154
155
156 ==== **1.3.3.1 via AT COMMAND:** ====
157
158 First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct.
159
160 (((
161 If the configured parameters and commands are incorrect, the return value is not obtained.
162 )))
163
164 [[image:image-20220527092748-9.png]]
165
166 AT COMMAND
167
168
169 (% class="box infomessage" %)
170 (((
171 AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
172 )))
173
174 a:  length for the return of AT+COMMAND
175
176 b: 1: grab valid value by byte, max 6 bytes;  2: grab valid value by bytes section, max 3 sections.
177
178 c:  define the position for valid value.
179
180 [[image:image-20220527092936-10.png]]
181
182 AT COMMAND
183
184
185
186 PAYLOAD is available after the valid value is intercepted.
187
188
189 [[image:image-20220527093059-11.png]]
190
191 AT COMMAND
192
193
194
195 You can get configured PAYLOAD on TTN.
196
197 [[image:image-20220527093133-12.png]]
198
199 (((
200 AT COMMAND
201 )))
202
203 (((
204
205 )))
206
207 (((
208 (% style="color:#4f81bd" %)**Example**:
209
210 CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
211 )))
212
213 (((
214 RETURN1:01 03 02 00 02 39 85 00 00(return data)
215 )))
216
217 (((
218 AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload.
219
220
221 )))
222
223 (((
224 CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1
225 )))
226
227 (((
228 RETURN2:01 03 02 08 DC BE 1D(return data)
229 )))
230
231 (((
232 AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload.
233
234
235 )))
236
237 (((
238 CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
239 )))
240
241 (((
242 RETURN3:01 03 04 00 00 00 44 FA 00(return data)
243 )))
244
245 (((
246 AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload.
247 )))
248
249 (((
250 Payload:01 00 02 39 85 08 DC 00 00 00 44
251 )))
252
253 [[image:image-20220527093204-13.png]]
254
255 AT COMMAND
256
257
258 (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
259
260 [[image:image-20220527093251-14.png]]
261
262 AT COMMAND
263
264
265 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
266
267 [[image:image-20220527093358-15.png]]
268
269 (((
270 DOWNLINK
271 )))
272
273 (((
274
275 )))
276
277 (((
278 (% style="color:#4f81bd" %)**Type Code 0xAF**
279 )))
280
281 (((
282 (% class="box infomessage" %)
283 (((
284 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
285 )))
286 )))
287
288 (((
289 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
290 )))
291
292 (((
293 Format: AF MM NN LL XX XX XX XX YY
294 )))
295
296 (((
297 Where:
298 )))
299
300 (((
301 MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
302 )))
303
304 (((
305 NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
306 )))
307
308 (((
309 LL: The length of AT+COMMAND or AT+DATACUT command
310 )))
311
312 (((
313 XX XX XX XX: AT+COMMAND or AT+DATACUT command
314 )))
315
316 (((
317 YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN
318 )))
319
320 (((
321 will execute an uplink after got this command.
322 )))
323
324 (((
325 (% style="color:#4f81bd" %)**Example:**
326 )))
327
328 (((
329 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
330 )))
331
332 [[image:image-20220527093430-16.png]]
333
334 DOWNLINK
335
336
337 [[image:image-20220527093508-17.png]]
338
339 DOWNLINK
340
341
342 [[image:image-20220527093530-18.png]]
343
344 DOWNLINK
345
346
347 [[image:image-20220527093607-19.png]]
348
349 DOWNLINK
350
351
352 [[image:image-20220527093628-20.png]]
353
354 DOWNLINK
355
356
357 === **1.3.4 How to configure and output commands for RS485 to USB** ===
358
359 (((
360 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN.
361 )))
362
363 (((
364 First, connect the A+ and A- of the USB to the 485 A and 485 B of the energy meter.
365 )))
366
367 (((
368 Open the serial port debugging, set the send and receive to HEX.
369 )))
370
371 (((
372 Baud rate: 9600
373 )))
374
375 (((
376 check digit: Even
377 )))
378
379 [[image:image-20220527093708-21.png]]
380
381 USB
382
383
384 [[image:image-20220527093747-22.png]]
385
386 USB
387
388
389 (((
390 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command.
391 )))
392
393 (((
394 (% style="color:#4f81bd" %)**Example:**  (%%)input:01 03 00 31 00 02 95 c4
395 )))
396
397 (((
398 output:01 03 04 00 00 00 42 7A 02
399 )))
400
401 [[image:image-20220527093821-23.png]]
402
403 USB
404
405
406 === **1.3.5 How to configure multiple devices and modify device addresses** ===
407
408 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01.
409
410 (((
411 (((
412 Set the device address according to the parameters in the appendix of the MODBUS communication protocol.
413 )))
414 )))
415
416 [[image:image-20220527093849-24.png]]
417
418
419 **Example**:These two meters are examples of setting parameters and device addresses.
420
421 [[image:image-20220527093950-25.png]]
422
423 [[image:image-20220527094028-26.png]]
424
425 (((
426 (((
427 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address.
428 )))
429 )))
430
431 (((
432 (((
433 We can use AT+CFGDEV to set the device address.
434 )))
435 )))
436
437 (((
438 (((
439 We modify the device address 01 of the first energy meter to 02.
440 )))
441 )))
442
443 [[image:image-20220527094100-27.png]]
444
445 (% class="box infomessage" %)
446 (((
447 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1**
448 )))
449
450 * 01:device adaress
451
452 * 10:function code
453
454 * 00 61:Register address
455
456 * 00 01:Number of Registers
457
458 * 02:Number of bytes
459
460 * 00 02:Modified device address
461
462 * 1:Check code
463
464 The device address setting of the energy meter is complete.
465
466 Another energy meter is a single active energy meter with a floating-point format.
467
468 Its default device address is 01, and the following are the parameters for configuring two energy meters.
469
470 [[image:image-20220527094150-28.png]]
471
472
473 [[image:image-20220527094224-29.png]]
474
475 **PAYLOAD:01 08 DF 43 62**
476
477 * 08 DF is the valid value of the meter with device address 02.
478 * 43 62 is the valid value of the meter with device address 01.
479
480
481 == 1.4 Example 4: Circuit Breaker Remote Open Close ==
482
483 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
484
485 [[image:image-20220527094330-30.png]]
486
487 Connection
488
489 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
490
491
492 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
493
494 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
495
496 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf]] : Configure Document For RS485-BL
497
498 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
499
500 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
501
502 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
503
504 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
505
506 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
507
508 [[image:image-20220527094556-31.png]]
509
510 Network Structure